152 research outputs found

    Quantitative imaging of concentrated suspensions under flow

    Full text link
    We review recent advances in imaging the flow of concentrated suspensions, focussing on the use of confocal microscopy to obtain time-resolved information on the single-particle level in these systems. After motivating the need for quantitative (confocal) imaging in suspension rheology, we briefly describe the particles, sample environments, microscopy tools and analysis algorithms needed to perform this kind of experiments. The second part of the review focusses on microscopic aspects of the flow of concentrated model hard-sphere-like suspensions, and the relation to non-linear rheological phenomena such as yielding, shear localization, wall slip and shear-induced ordering. Both Brownian and non-Brownian systems will be described. We show how quantitative imaging can improve our understanding of the connection between microscopic dynamics and bulk flow.Comment: Review on imaging hard-sphere suspensions, incl summary of methodology. Submitted for special volume 'High Solid Dispersions' ed. M. Cloitre, Vol. xx of 'Advances and Polymer Science' (Springer, Berlin, 2009); 22 pages, 16 fig

    Evaluating the Viscoelastic Properties of Tissue from Laser Speckle Fluctuations

    Get PDF
    Most pathological conditions such as atherosclerosis, cancer, neurodegenerative, and orthopedic disorders are accompanied with alterations in tissue viscoelasticity. Laser Speckle Rheology (LSR) is a novel optical technology that provides the invaluable potential for mechanical assessment of tissue in situ. In LSR, the specimen is illuminated with coherent light and the time constant of speckle fluctuations, Ο„, is measured using a high speed camera. Prior work indicates that Ο„ is closely correlated with tissue microstructure and composition. Here, we investigate the relationship between LSR measurements of Ο„ and sample mechanical properties defined by the viscoelastic modulus, G*. Phantoms and tissue samples over a broad range of viscoelastic properties are evaluated using LSR and conventional mechanical testing. Results demonstrate a strong correlation between Ο„ and |G*| for both phantom (r = 0.79, p <0.0001) and tissue (r = 0.88, p<0.0001) specimens, establishing the unique capability of LSR in characterizing tissue viscoelasticity

    Discovery of serum biomarkers for pancreatic adenocarcinoma using proteomic analysis

    Get PDF
    Background and aims:The serum/plasma proteome was explored for biomarkers to improve the diagnostic ability of CA19-9 in pancreatic adenocarcinoma (PC).Methods:A Training Set of serum samples from 20 resectable and 18 stage IV PC patients, 54 disease controls (DCs) and 68 healthy volunteers (HVs) were analysed by surface-enhanced laser desorption and ionisation time-of-flight mass spectrometry (SELDI-TOF MS). The resulting protein panel was validated on 40 resectable PC, 21 DC and 19 HV plasma samples (Validation-1 Set) and further by ELISA on 33 resectable PC, 28 DC and 18 HV serum samples (Validation-2 Set). Diagnostic panels were derived using binary logistic regression incorporating internal cross-validation followed by receiver operating characteristic (ROC) analysis.Results:A seven-protein panel from the training set PC vs DC and from PC vs HV samples gave the ROC area under the curve (AUC) of 0.90 and 0.90 compared with 0.87 and 0.91 for CA19-9. The AUC was greater (0.97 and 0.99, P0.05) when CA19-9 was added to the panels and confirmed on the validation-1 samples. A simplified panel of apolipoprotein C-I (ApoC-I), apolipoprotein A-II (ApoA-II) and CA19-9 was tested on the validation-2 set by ELISA, in which the ROC AUC was greater than that of CA19-9 alone for PC vs DC (0.90 vs 0.84) and for PC vs HV (0.96 vs 0.90).Conclusions:A simplified diagnostic panel of CA19-9, ApoC-I and ApoA-II improves the diagnostic ability of CA19-9 alone and may have clinical utility

    The Impact of Worry on Attention to Threat

    Get PDF
    Prior research has often linked anxiety to attentional vigilance for threat using the dot probe task, which presents probes in spatial locations that were or were not preceded by a putative threat stimulus. The present study investigated the impact of worry on threat vigilance by administering this task during a worry condition and during a mental arithmetic control condition to 56 undergraduate students scoring in the low normal range on a measure of chronic worry. The worry induction was associated with faster responses than arithmetic to probes in the attended location following threat words, indicating the combined influence of worry and threat in facilitating attention. Within the worry condition, responses to probes in the attended location were faster for trials containing threat words than for trials with only neutral words, whereas the converse pattern was observed for responses to probes in the unattended location. This connection between worry states and attentional capture by threat may be central to understanding the impact of hypervigilance on information processing in anxiety and its disorders

    Inferring the Transcriptional Landscape of Bovine Skeletal Muscle by Integrating Co-Expression Networks

    Get PDF
    Background: Despite modern technologies and novel computational approaches, decoding causal transcriptional regulation remains challenging. This is particularly true for less well studied organisms and when only gene expression data is available. In muscle a small number of well characterised transcription factors are proposed to regulate development. Therefore, muscle appears to be a tractable system for proposing new computational approaches. Methodology/Principal Findings: Here we report a simple algorithm that asks "which transcriptional regulator has the highest average absolute co-expression correlation to the genes in a co-expression module?" It correctly infers a number of known causal regulators of fundamental biological processes, including cell cycle activity (E2F1), glycolysis (HLF), mitochondrial transcription (TFB2M), adipogenesis (PIAS1), neuronal development (TLX3), immune function (IRF1) and vasculogenesis (SOX17), within a skeletal muscle context. However, none of the canonical pro-myogenic transcription factors (MYOD1, MYOG, MYF5, MYF6 and MEF2C) were linked to muscle structural gene expression modules. Co-expression values were computed using developing bovine muscle from 60 days post conception (early foetal) to 30 months post natal (adulthood) for two breeds of cattle, in addition to a nutritional comparison with a third breed. A number of transcriptional landscapes were constructed and integrated into an always correlated landscape. One notable feature was a 'metabolic axis' formed from glycolysis genes at one end, nuclear-encoded mitochondrial protein genes at the other, and centrally tethered by mitochondrially-encoded mitochondrial protein genes. Conclusions/Significance: The new module-to-regulator algorithm complements our recently described Regulatory Impact Factor analysis. Together with a simple examination of a co-expression module's contents, these three gene expression approaches are starting to illuminate the in vivo transcriptional regulation of skeletal muscle development

    Analysis of two methods of isometric muscle contractions during the anti-G straining maneuver

    Full text link
    This study investigated the difference in Mean Arterial Pressure (MAP) and Cardiac Output (CO) between two methods of isometric muscle contractions during the Anti-G Straining Maneuver (AGSM). 12 subjects (ages 18 to 38 yrs, height 176.8 +/- 7.4 cm, body mass 78.8 +/- 15.6 kg, percent body fat 14.3 +/- 6.6%) participated in the study. The study was a one-way within-subject design with test conditions counterbalanced. Two methods of isometric muscle contractions lasting 30 seconds each were assessed; an isometric push contraction and an isometric muscle tensing contraction. The dependent parameters were MAP and CO. The average MAP during the push contraction was 123 mmHg, SD +/- 11 and for tense was 118 mmHg, SD +/- 8. CO was 7.6 L/min, SD +/- 1.6 for push and 7.9 L/min, SD +/- 2.0 for tense method. Dependent t-tests revealed t(11) = 1.517, p = 0.157 for MAP and t(11) = 0.875, p = 0.400 for CO. This study demonstrated that the two methods of isometric muscle contractions were not statistically different with regards to MAP and CO. Therefore, both forms of isometric contractions may be potentially useful when performing the muscle contraction portion of the AGSM
    • …
    corecore