10,317 research outputs found

    RI/MOM Renormalization Window and Goldstone Pole Contamination

    Get PDF
    We perform a comparative study of the ratio of lattice (Wilson fermion) renormalization constants Z_P/Z_S, obtained non-perturbatively from the RI/MOM renormalization conditions and from Ward Identities of on- and off-shell Green's functions. The off-shell Ward Identity used in this work relies on correlation functions with non-degenerate quark masses. We find that, due to discretization effects, there is a 10-15% discrepancy between the two Ward Identity determinations at current bare couplings (beta values). The RI/MOM result is in the same range and has a similar systematic error of 10-15%. Thus, contrary to a previous claim, the contamination of the RI/MOM result from the presence of a Goldstone pole at scales of about 2 GeV is subdominant, compared to finite cutoff effects.Comment: LATEX, 12 pages final version to appear on Phys. Lett.

    Nellix endovascular aortic sealing endoprosthesis late explantation for concomitant type I endoleak and stent frames proximal caudal migration

    Get PDF
    Endovascular aneurysm sealing (EVAS) using the Nellix™ System was introduced in clinical practice with the aim of reducing the incidence of complications such as migration, endoleaks, and reinterventions after conventional endovascular aneurysm repair (EVAR). Although, initial efficacy data on this device have been encouraging, EVAS has also demonstrated to undergo adverse events. Herein, we report a case of Nellix graft explant due to endobags shrinkage after air bubble reabsorption leading to proximal type I A endoleak and stent migration. The focus of this article is on the importance of a more assiduous surveillance of this new device, in particular in those cases with air into the endobags immediately after the procedure; this surveillance should be aimed to timely identify complications which can otherwise lead to consequences that require open conversion

    Effect of Ru susbstitution on atomic displacements in the layered SmFe_{1-x}Ru_xAsO_{0.85}F_{0.15} superconductor

    Full text link
    The effect of Ru substitution on the local structure of layered SmFe1x_{1-x}Rux_xAsO0.85_{0.85}F0.15_{0.15} superconductor has been studied by As KK- and Sm L3L_3 - edges x-ray-absorption spectroscopy. The extended x-ray-absorption fine-structure measurements reveal distinct Fe-As and Ru-As bondlengths in the Ru substituted samples with the latter being \sim0.03 \AA\ longer. Local disorder induced by the Ru substitution is mainly confined to the FeAs layer while the SmO spacer layer sustains a relative order, consistent with the x-ray-absorption near-edge structure spectra. The results suggest that, in addition to the order/disorder in the active active iron-arsenide layer, its coupling to the rare-earth\textminus oxygen spacer layer needs to be considered for describing the electronic properties of these layered superconductors

    Single-center experience in the treatment of visceral artery aneurysms

    Get PDF
    Background: Visceral artery aneurysms (VAAs), although rare, represent a life-threatening disease with high mortality rates. With the more frequent use of diagnostic tests, there has been an incidental detection of these lesions which are mostly asymptomatic. It follows that surgeons are increasingly called to decide on the most appropriate management of VAAs between an open surgical or endovascular approach and among the different endovascular options currently available. The aim of this retrospective study was to evaluate the results of open surgery and interventional endovascular strategies of visceral artery aneurysms with respect to technical success, therapy-associated complications, and postinterventional follow-up in the elective and emergency situation. Methods: From January 1992 to January 2017, 125 open surgical or endovascular interventions for VAA were performed at our institution. Once the VAA was diagnosed and the indication for treatment was assessed, the preoperative diagnostic work-up consisted of contrast computed tomography (CT) or magnetic resonance imaging (MRI) and, in some patients, digital subtraction angiography. Follow-up included clinical and duplex ultrasound scan (DUS) and contrast-enhanced ultrasound to assess the treated vessel patency and organ perfusion after 1, 6, and 12 months, and yearly thereafter. CT or MRI controls were also performed at 1 year of follow-up and only when DUS was not diagnostic or showed a complication thereafter. After the first 5 years of follow-up, the status of the patient was obtained by a structured telephone survey. Results: The treatment option was endovascular in 56 of 125 cases (44.8%). Technical success was 98.3%. In one case, the procedure was interrupted for the extensive dissection of the afferent vessel. Twenty-six patients were treated by coil embolization while 29 with covered stenting. The endovascular approach was in emergency in two cases (3.6%). In the endovascular group, mortality was nil. Complications occurred in 5 cases (8.9%): 1 subacute intestinal ischemia caused by superior mesenteric artery dissection, 2 aneurysm reperfusion, 1 stent thrombosis, and 1 massive splenic hematoma. In 69 (55.2%) cases, surgical treatment was preferred, with 24 VAA resections and 45 arterial reconstructions. In 20 cases (29%), open surgery was performed in emergency conditions. In the surgical group, 8 emergency patients (40%) died intraoperatively. The mortality after elective surgical interventions was nil. Complications after surgery were 4 graft late thrombosis (5.8%): asymptomatic in three cases and requiring splenectomy in one. Conclusions: There is no overall consensus regarding the indications for treatment of VAA. Currently in emergent setting, the endovascular approach should be considered as the first choice because of its reduced invasiveness, faster way to access and bleeding control; this accounts for the lower morality of the interventional therapy than open surgery. Endovascular approach is effective for elective repair of VAAs, but procedure-related complications may occur in a not negligible number of patients. Given comparable mortality rates and low procedure-related complication rate, surgical approach still has space in the elective management of VAAs, especially for aneurysms unsuitable or challenging for the endovascular option in patients with low surgical risk. The size, location, and morphology of VAAs, systemic or local comorbidities, and specific anatomical situations such as previous abdominal surgery should dictate treatment choice

    Outcomes in the emergency endovascular repair of blunt thoracic aortic injuries

    Get PDF
    Abstract Thoracic aorta blunt injury (BAI) is a highly lethal lesion. A large number of victims die before obtaining emergency care. Thoracic endovascular aneurysm repair (TEVAR) is a less invasive method compared with open surgery and may change protocols for BAI treatment. This retrospective study was developed to evaluate the potential issues about thoracic endografting in the management of these patients. Twenty-seven patients with a BAI underwent aortic stent grafting. Intervention was preceded by the treatment of more urgent associated lesions in nine cases. In-hospital mortality was 7.4%. No paraplegia or ischemic complications developed because of the coverage of the left subclavian artery. In one case (3.2%), a type I endoleak was detected, proximal endograft infolding in two cases (7.4%) and endograft distal migration in further two cases were detected during follow-up (6-110 months). Thoracic endovascular aneurysm repair of BAI showed encouraging results in terms of perioperative mortality and morbidity. Concerns still remain about the potential mid- and long-term complications in younger patients

    Two-body nonleptonic B decays in the Standard Model and beyond

    Full text link
    We briefly discuss the phenomenology of B to pi pi, B to K pi and B to phi K decays in the Standard Model and in Supersymmetry.Comment: 7 pages, 2 figures, uses moriond.sty. Talk given by L. Silvestrini at the XXXIXth Rencontres de Moriond on ElectroWeak Interactions and Unified Theories, La Thuile, Aosta Valley, Italy, March 21st-28th 200

    Quenched Hadron Spectrum and Decay Constants on the lattice

    Get PDF
    In this talk we present the results obtained from a study of O(2000){\cal O}(2000) (quenched) lattice configurations from the APE collaboration, at 6.0β6.46.0\le\beta\le 6.4, using both the Wilson and the SW-Clover fermion action. We determine the light hadronic spectrum and the meson decay constants. For the light-light systems we find an agreement with the experimental data of 5\sim 5% for mesonic masses and 10\sim 10%-15% for baryonic masses and pseudoscalar decay constants; a larger deviation is present for the vector decay constants. For the heavy-light decay constants we find fDs=237±16MeV,fD=221±17MeV(fDs/fD=1.07(4)),fBs=205±35MeV,fB=180±32MeV(fBs/fB=1.14(8))f_{D_s}=237 \pm 16 MeV, f_{D} = 221 \pm 17 MeV (f_{D_s}/f_D=1.07(4)), f_{B_s} = 205 \pm 35 MeV, f_{B} = 180 \pm 32 MeV (f_{B_s}/f_B=1.14(8)), in good agreement with previous estimates.Comment: 8 pages, latex, Talk given at XXV ITEP Winter School of Physics, Moscow - Russia, 18-27 Feb 199

    Generation of Bright Two-Color Continuous Variable Entanglement

    Full text link
    We present the first measurement of squeezed-state entanglement between the twin beams produced in an Optical Parametric Oscillator (OPO) operating above threshold. Besides the usual squeezing in the intensity difference between the twin beams, we have measured squeezing in the sum of phase quadratures. Our scheme enables us to measure such phase anti-correlations between fields of different frequencies. In the present measurements, wavelengths differ by ~1 nm. Entanglement is demonstrated according to the Duan et al. criterion [Phys. Rev. Lett. 84, 2722 (2000)] Δ2p^+Δ2q^+=1.47(2)<2\Delta^2\hat{p}_- +\Delta^2\hat{q}_+=1.47(2)<2. This experiment opens the way for new potential applications such as the transfer of quantum information between different parts of the electromagnetic spectrum.Comment: 4 pages, 3 figures, submitted to Phys. Rev. Let

    Non-perturbative Renormalization of the Complete Basis of Four-fermion Operators and B-parameters

    Get PDF
    We present results on the B-parameters BKB_K, B73/2B^{3/2}_7 and B83/2B^{3/2}_8, at β=6.0\beta=6.0, with the tree-level Clover action. The renormalization of the complete basis of dimension-six four-fermion operators has been performed non-perturbatively. Our results for BKB_K and B73/2B^{3/2}_7 are in reasonable agreement with those obtained with the (unimproved) Wilson action. This is not the case for B83/2B^{3/2}_8. We also discuss some subtleties arising from a recently proposed modified definition of the B-parameters.Comment: Talk presented at Lattice '97, Edinburgh (UK), July 1997. LaTeX 3 pages, uses espcrc
    corecore