49 research outputs found
Surgical fixation with K-wires versus casting in adults with fracture of distal radius: DRAFFT2 multicentre randomised clinical trial
Objective
To assess wrist function, quality of life, and complications in adult patients with a dorsally displaced fracture of the distal radius, treated with either a moulded cast or surgical fixation with K-wires.
Design
Multicentre randomised clinical superiority trial,
Setting
36 hospitals in the UK National Health Service (NHS).
Participants
500 adults aged 16 or over with a dorsally displaced fracture of the distal radius, randomised after manipulation of their fracture (255 to moulded cast; 245 to surgical fixation).
Interventions
Manipulation and moulded cast was compared with manipulation and surgical fixation with K-wires plus cast. Details of the application of the cast and the insertion of the K-wires were at the discretion of the treating surgeon, according to their normal clinical practice.
Main outcome measures
The primary outcome measure was the Patient Rated Wrist Evaluation (PRWE) score at 12 months (five questions about pain and 10 about function and disability; overall score out of 100 (best score=0 and worst score=100)). Secondary outcomes were PRWE score at three and six months, quality of life, and complications, including the need for surgery due to loss of fracture position in the first six weeks.
Results
The mean age of participants was 60 years and 417 (83%) were women; 395 (79%) completed follow-up. No statistically significant difference in the PRWE score was seen at 12 months (cast group (n=200), mean 21.2 (SD 23.1); K-wire group (n=195), mean 20.7 (22.3); adjusted mean difference −0.34 (95% confidence interval −4.33 to 3.66), P=0.87). No difference was seen at earlier time points. In the cast group, 33 (13%) of participants needed surgical fixation for loss of fracture position in the first six weeks compared with one revision surgery in the K-wire group (odds ratio 0.02, 95% confidence interval 0.001 to 0.10).
Conclusions
Among patients with a dorsally displaced distal radius fracture that needed manipulation, surgical fixation with K-wires did not improve patients’ wrist function at 12 months compared with a cast.
Trial registration ISRCTN registry ISRCTN1198054
Comparison of DNA flow cytometry from fresh and paraffin embedded samples of non-Hodgkin's lymphoma.
Sex differences in associations between creatinine and cystatin C-based kidney function measures with stroke and major bleeding
No abstract available