17,197 research outputs found

    Design Considerations and Structural Analysis of the Narrow Channel Facility

    Get PDF
    The narrow channel (NC) facility design is based on the GALCIT Detonation Tube (GDT) test section design of Mike Kaneshige [3]. The main differences are 1) the design of the longitudinal bolted joint was simplified and 2) the keys for the flanges are not designed to assist with shear loading. The GDT side windows and PLIF window may be used in the NC facility. 304 SS was chosen for its excellent corrosion resistance. The yield strength is 275 MPa. 304 SS is non-magnetic and is therefore more difficult to grind on a table with magnetic locking. All four plates were blanchard ground (using mechanical locking to the table through some of the bolt holes which were drilled before grinding) by a subcontractor for Hales. All pieces were machined by Hales except the initiator, window sealing plates, end flange sealing plates which were made by the Aeroshop. Hales also supplied the material and checked the assembly of the pieces. After delivery from Hales, the internal surfaces of the four channel plates were hand-sanded to a mirror finish

    Vacuum Photon Splitting in Lorentz-Violating Quantum Electrodynamics

    Get PDF
    Radiative corrections arising from Lorentz violation in the fermion sector induce a nonzero amplitude for vacuum photon splitting. At one loop, the on-shell amplitude acquires both CPT-even and CPT-odd contributions forbidden in conventional electrodynamics.Comment: 4 pages, minor wording changes, references added, accepted in Physical Review Letter

    Vascular Dysfunction and Posttraumatic Stress Disorder: Examining the Role of Oxidative Stress and Sympathetic Activity

    Get PDF
    Purpose: The physiological manifestations of posttraumatic stress disorder (PTSD) have been associated with an increase in risk of cardiovascular disease (CVD) independent of negative lifestyle factors. The goal of the study was to better elucidate the mechanisms behind the increased CVD risk by examining peripheral vascular function, a precursor to CVD. Moreover, this study sought to determine the role of oxidative stress and sympathetic nervous system (SNS) activity in PTSD-induced vascular dysfunction. Methods: Sixteen individuals with PTSD (10 women, 6 men; age 24 ± 4 years), and twenty-four healthy controls (CTRL; 15 women, 9 men, 24 ± 4 years), participated in the study. The PTSD group participated in two visits, consuming either a placebo or antioxidant cocktail (AO - vitamins C and E and alpha lipoic acid) prior to their visits, in a randomized order. Arm vascular function was assessed via the reactive hyperemia- induced flow mediated dilation of the brachial artery (BAFMD) technique and evaluated with Doppler ultrasonography. Brachial artery and arm microvascular function were determined by percent change of diameter from baseline normalized for BA shear rate (BAD/Shear), and blood flow area under the curve (BF AUC), respectively. Heart rate variability (HRV) was used to assess autonomic nervous system activity. Results: BF AUC was significantly lower (p = 0.02) and SNS activity was significantly higher (p = 0.02) in the PTSD group when compared to the CTRL group. BAD/Shear was not different between groups. Following the acute AO supplementation, BF AUC was augmented to which it was no longer significantly different (p = 0.16) when compared to the CTRL group. SNS activity within the PTSD group was significantly reduced (p=.007) following the AO supplementation when compared to the PL condition, and the difference between PTSD and CTRL was no longer significant (p=.41). Conclusion: Young individuals with PTSD demonstrated lower arm microvascular, but not brachial artery, function as well as higher sympathetic activity when compared to healthy controls matched for age, sex, and physical activity level. Furthermore, this microvascular dysfunction and SNS activity was attenuated by an acute AO supplementation to the level of the healthy controls. Taken together, this study revealed that the modulation of oxidative stress, via an acute AO supplementation, improved vascular dysfunction in individuals with PTSD, potentially by reducing the substantial SNS activity associated with this disorder.https://scholarscompass.vcu.edu/gradposters/1084/thumbnail.jp

    Maximum entanglement of formation for a two-mode Gaussian state over passive operations

    Get PDF
    We quantify the maximum amount of entanglement of formation (EoF) that can be achieved by continuous-variable states under passive operations, which we refer to as EoF-potential. Focusing, in particular, on two-mode Gaussian states we derive analytical expressions for the EoF-potential for specific classes of states. For more general states, we demonstrate that this quantity can be upper-bounded by the minimum amount of squeezing needed to synthesize the Gaussian modes, a quantity called squeezing of formation. Our work, thus, provides a new link between non-classicality of quantum states and the non-classicality of correlations.Comment: Revised versio

    Elemental bio-imaging of trace elements in teeth using laser ablation-inductively coupled plasma-mass spectrometry

    Full text link
    Objectives: In this study we present the application of a novel laboratory method that employs laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS) to construct two-dimensional maps of trace elements in teeth. Methods: Teeth were sectioned longitudinally, embedded in resin and polished to a smooth surface. Data were generated by laser ablating the entire sectioned tooth surface. Elemental images were constructed using custom-built software. Results: Quantified images of 66Zn, 88Sr, 111Cd and 208Pb, with a spatial resolution of 30 μm2, were generated from three teeth. Concentrations were determined by single-point calibration against NIST SRM 1486 (bone meal). Zn and Sr concentrations were determined in the μg g-1 range and Cd and Pb in the ng g -1 range. Concentrations of Pb, Zn and Cd were higher in dentine particularly in regions adjacent the pulp. Conclusions: Elemental bio-imaging employing LA-ICP-MS is a novel method for constructing μm-scale maps of trace elements in teeth. This simple imaging method displays the heterogeneity of trace elements throughout the tooth structure that correspond to specific structural and developmental features of teeth. As a preliminary study, this work demonstrates the capabilities of LA-ICP-MS imaging in dental research. © 2011 Elsevier Ltd. All rights reserved

    Morphodynamic variability of high-energy macrotidal beaches, Cornwall, UK

    Get PDF
    The full text is under embargo until 01.04.16

    Photometric Confirmation of MACHO Large Magellanic Cloud Microlensing Events

    Full text link
    We present previously unpublished photometry of three Large Magellanic Cloud (LMC) microlensing events and show that the new photometry confirms the microlensing interpretation of these events. These events were discovered by the MACHO Project alert system and were also recovered by the analysis of the 5.7 year MACHO data set. This new photometry provides a substantial increase in the signal-to-noise ratio over the previously published photometry and in all three cases, the gravitational microlensing interpretation of these events is strengthened. The new data consist of MACHO-Global Microlensing Alert Network (GMAN) follow-up images from the CTIO 0.9 telescope plus difference imaging photometry of the original MACHO data from the 1.3m "Great Melbourne" telescope at Mt. Stromlo. We also combine microlensing light curve fitting with photometry from high resolution HST images of the source stars to provide further confirmation of these events and to show that the microlensing interpretation of event MACHO-LMC-23 is questionable. Finally, we compare our results with the analysis of Belokurov, Evans & Le Du who have attempted to classify candidate microlensing events with a neural network method, and we find that their results are contradicted by the new data and more powerful light curve fitting analysis for each of the four events considered in this paper. The failure of the Belokurov, Evans & Le Du method is likely to be due to their use of a set of insensitive statistics to feed their neural networks.Comment: 29 pages with 8 included postscript figures, accepted by the Astrophysical Journa
    corecore