40 research outputs found

    A hot spot of olive biodiversity in the Tunisian oasis of degache

    Get PDF
    Tunisia is one of the world's largest producers of olive oil, and it preserves pools of olive genetic diversity that are still unexplored. A recent prospection and collection program of the National Gene Bank of Tunisia (NGBT) focused on the vast oasis of Degache, in the south west part of Tunisia, where 47 samples were collected and genetically characterized through simple sequence repeat (SSR) markers. Identification and authentication of genotypes were obtained through comparison with reference cultivars belonging to the Olive National Collection of Tunisia (IOC) and with cultivars from Algeria, Italia, Syria and Lebanon. Degache olive genotypes showed large genetic variability, a significant diversity from the reference germplasm, and a clear differentiation from modern varieties. The population structure analysis identified four gene pools characterizing genotypes from different area of origin. Two gene pools appear to be more represented in germplasm from southern Tunisia, where environmental conditions at critical plant development phases, are harsher. This suggests that this germplasm might present traits of adaptation useful for breeding to improve resilience to abiotic stresses. Our results will support ex situ and in situ conservation activities of Tunisian olive germplasm pursued by the National Gene Bank of Tunisia

    Structural Characterization of Magnetic Nano-particles Suspensions, Using Magnetic Measurements

    Get PDF
    P curves, Magnetic fluids, Ferrofluids, Nanostructural characterization, Magnetic powders, Hysteresis curve, Magnetic nanocomposite materialsThe paper describes some characteristics of the “P” curves for structural characterization of magnetic nano-particles suspensions (complex fluids, complex powders, complex composite materials, or living biological materials having magnetic properties). In the case of these materials, the magnetic properties are conferred to various carrier liquids by artificially integrating in their structure ferromagnetic particles of different sizes. The magnetic properties are usually shown by the hysteresis curve. The structure can be seen on (electronic) micrography. The P curves offer another possibility to determine the structure of the magnetic component of a complex fluid by numerical analysis of the magnetization curve experimentally obtained. The paper presents a detailed approach of the P curves and some limitations in their use

    Fabrication and characterization of micro-inductors deposited on magnetic thin and thick layers

    Get PDF
    This paper presents two fabrication techniques of spiral integrated inductors based on magnetic materials. For the first one, the magnetic core is a thin film deposited by RF magnetron sputtering, for the second technique the magnetic core is a thick layer of YIG obtained by micromachining. The addition of the magnetic material is expected to improve the performances of the integrated structure with electromagnetic shield. Low and high frequency equipment are used to characterize the manufactured components. A good correlation is obtained between the results by simulation and measurements for the two manufacturing techniques. These results show that the inductance increases when the thickness of the magnetic layer increases, we can double the inductance value for a thickness sufficiently high

    Esophageal and Gastric Malignancies After Bariatric Surgery: a Retrospective Global Study

    Get PDF
    Background: Bariatric surgery can influence the presentation, diagnosis, and management of gastrointestinal cancers. Esophagogastric (EG) malignancies in patients who have had a prior bariatric procedure have not been fully characterized. Objective: To characterize EG malignancies after bariatric procedures. Setting: University Hospital, United Kingdom. Methods: We performed a retrospective, multicenter observational study of patients with EG malignancies after bariatric surgery to characterize this condition. Results: This study includes 170 patients from 75 centers in 25 countries who underwent bariatric procedures between 1985 and 2020. At the time of the bariatric procedure, the mean age was 50.2 ± 10 years, and the mean weight 128.8 ± 28.9 kg. Women composed 57.3% (n = 98) of the population. Most (n = 64) patients underwent a Roux-en-Y gastric bypass (RYGB) followed by adjustable gastric band (AGB; n = 46) and sleeve gastrectomy (SG; n = 43). Time to cancer diagnosis after bariatric surgery was 9.5 ± 7.4 years, and mean weight at diagnosis was 87.4 ± 21.9 kg. The time lag was 5.9 ± 4.1 years after SG compared to 9.4 ± 7.1 years after RYGB and 10.5 ± 5.7 years after AGB. One third of patients presented with metastatic disease. The majority of tumors were adenocarcinoma (82.9%). Approximately 1 in 5 patients underwent palliative treatment from the outset. Time from diagnosis to mortality was under 1 year for most patients who died over the intervening period. Conclusion: The Oesophago-Gastric Malignancies After Obesity/Bariatric Surgery study presents the largest series to date of patients developing EG malignancies after bariatric surgery and attempts to characterize this condition.info:eu-repo/semantics/publishedVersio

    Structural Characterization of Magnetic Nano-particles Suspensions, Using Magnetic Measurements

    No full text
    Submitted on behalf of EDA Publishing Association (http://irevues.inist.fr/handle/2042/5920)International audienceThe paper describes some characteristics of the "P" curves for structural characterization of magnetic nano-particles suspensions (complex fluids, complex powders, complex composite materials, or living biological materials having magnetic properties). In the case of these materials, the magnetic properties are conferred to various carrier liquids by artificially integrating in their structure ferromagnetic particles of different sizes. The magnetic properties are usually shown by the hysteresis curve. The structure can be seen on (electronic) micrography. The P curves offer another possibility to determine the structure of the magnetic component of a complex fluid by numerical analysis of the magnetization curve experimentally obtained. The paper presents a detailed approach of the P curves and some limitations in their use

    Comparison between a magneto-optical method and Fannin's technique for measuring Brown's relaxation frequency of ferrofluids

    No full text
    International audienc

    Dielectric study of primary amines from room temperature down to −180 °C and from 10 kHz up to 35 GHz

    No full text
    The aim of this paper is to present the NH2 dielectric behaviour in the primary amines for the importance it bears in the interaction of aminoacids and proteins and their influence in the electric conduction processes. For that, the dielectric properties of 1-propylamine, 1-butylamine and 1-pentylamine have been studied. Measurements were performed between room temperature and −180 °C in the low frequency range and micro-waves measurements were done between −40 °C and 25 °C. The isofrequency recordings of dispersion ε′ and absorption ε′′, for these three primary amines, show clearly the relaxations and the effect of the aliphatic chain length

    Physico-chemical characterization of multilayer YIG thin film deposited by rf sputtering

    No full text
    Yttrium iron garnet (YIG) film made as a magneto-optical medium suffers from the problem of crack formation, caused by the heating process. YIG thin film is deposited by radio frequency rf magnetron sputtering; the obtained layer is amorphous and it needs annealing to be crystallized. After heat-treatment at 740 ○C of the sample realized on quartz substrate, we observe cracks on the entire film surface. This is due to the large difference between the thermal expansion coefficient (5.5 ×10-7 K-1 for quartz and 10 × 10-6 K-1 for YIG). In this paper we present a new fabrication method to reduce this problem, we make a multilayer to obtain at the end a uniformly unique layer with excellent crystalline structure. Such films have the possibility to reach a thickness of 500 nm. YIG films have been studied by Rutherford backscattering spectrometry (RBS), optic ellipsometry and the scan electron microscope. The RBS spectra were collected in channelling geometry with incident particles energy 2 MeV and 3.5 MeV. The thickness and the stoichiometric value of the thin films have been evaluated. Simulation of all spectra indicates a constant composition. Ellipsometry method is well adapted to model the thin film structure layers, and to measure the thickness of the film and the complex index of refraction. The theoretical ellipsometric value of the index of refraction is (2.22) while the experimental value is ranging from 2.2 to 2.3 for a wavelength of 1550 nm
    corecore