2 research outputs found

    Quantitative Analysis Procedure for Building Materials in Historic Buildings by Applying Infrared Thermography

    Full text link
    [EN] Historic buildings have a great cultural and architectural value. It is necessary to analyze their state of conservation, but sometimes it is difficult to perform laboratory tests without damaging this heritage. In the field of architecture, infrared thermography is usually used to provide descriptive information about the surface temperature of building materials. This current research presents a methodology widely applicable to historic buildings. As an example of application, the study is focused in the Seminary-School of Corpus Christi of Valencia (Spain), a very outstanding building from the 16th Century. This research presents an analytical study to be able to differentiate the temperature distribution of all pixels of a thermographic image. Thermal images are a matrix of data and their study helps us in decision-making based on objective data.Lerma Elvira, C.; Mas Tomas, MDLA.; Gil Benso, E.; Vercher Sanchis, JM.; Torner-Feltrer, MEM. (2018). Quantitative Analysis Procedure for Building Materials in Historic Buildings by Applying Infrared Thermography. Russian Journal of Nondestructive Testing. 54(8):601-609. https://doi.org/10.1134/S1061830918080065S601609548Avdelidis, N.P. and Moropoulou, A., Applications of infrared thermography for the investigation of historic structures, J. Cult. Heritage, 2004, no. 5, pp. 119–127. doi 10.1016/j.culher.2003.07.002Barreira, E. and Freitas, V., Evaluation of building materials using infrared thermography, Constr. Build. Mater., 2007, vol. 21, pp. 218–224. doi 10.1016/j.conbuildmat.2005.06.049Bauer, E., Pavón, E., Barreira, E., and Kraus, E., Analysis of building façade defects using infrared thermography: Laboratory studies, J. Build. Eng., 2016, no. 6, pp. 93–104. doi /doi 10.1016/j.jobe.2016.02.012Binda, L., Cardani, G., and Zanzi, L., Nondestructive testing evaluation of drying process in flooded full-scale masonry walls, J. Perform. Constr. Facil., 2010, pp. 473–483. doi 10.1061/(ASCE)CF.1943-5509.0000097Cañas, I., Martín, S., and González, I., Thermal-physical aspects of materials used for the construction of rural buildings in Soria (Spain), Construct. Build. Mater., 2005, vol. 19, pp. 197–211. doi 10.1016/j.conbuildmat. 2004.05.016Carlomagno, G.M., Maio, R., Fedi, M., Meola, C., Integration of infrared thermography and high-frequency electromagnetic methods in archaeological surveys, J. Geophys. Eng., 2011, vol. 8, pp. 93–105. doi 10.1088/1742-2132/8/3/S09Cerdeira, F., Vázquez, ME, Collado, J., and Granada, E., Applicability of infrared thermography to the study of the behavior of Stone panels as building envelopes, Energy Build., 2011, vol. 43, pp. 1845–1851. doi 10.1016/j.enbuild.2011.03.029EN 13187:1998. Thermal performance of buildings. Qualitative detection of thermal irregularities in building envelopes. Infrared method (ISO 6781:1983 modified).Galarza Tortajada, M., La tapia valenciana: una técnica constructiva poco conocida, Proc. First Natl. Congr. Construct. Hist., Madrid, 1996.Grinzato, E., Bison, P.G., and Marinetti, S., Monitoring of ancient buildings by the thermal method, J. Cult. Heritage, 2002, vol. 3, pp. 21–29. doi 10.1016/S1296-2074(02)01159-7Ibarra-Castanedo C., Sfarra, S., Ambrosini, D., Paoletti, D., Bendada, A, and Maldague, X., Diagnostics of panel paintings using holographic interferometry and pulsed thermography, Quant. Infrared Thermogr. J., 2010, vol. 7, no. 1. doi 10.3166/qirt.7.85-114Lagüela, S., Martínez, J., Armesto, J., and Arias, P., Energy efficiency studies through 3D laser scanning and thermographic technologies, Energy Build., 2011, vol. 43, pp. 1216–1221. doi 10.1016/j.enbuild.2010.12.031Lerma, C., Mas, Á., Gil, E., and Galiana, M., An analytical procedure for the study of the documented construction process of the Seminary-School of Corpus Christi in Valencia (Spain), Inf. Constr., 2014, vol. 66 (533), e007. doi 10.3989/ic.12.117Lerma, C., Mas, A., Gil, E., Vercher, J., and Penalver, M.J., Pathology of building materials in historic buildings. Relationship between laboratory testing and infrared thermography, Mater. Constr., 2014, vol. 64 (313), e009. doi 10.3989/mc.2013.06612Lerma, J.L., Cabrelles, M., and Portalés, C., Multitemporal thermal analysis to detect moisture on a building façade, Construct. Build. Mater., 2011, vol. 25, pp. 2190–2197. doi 10.1016/j.conbuildmat.2010.10.007Madruga, F.J., Ibarra-Castanedo, C., Conde, O., López-Higuera, J.M., and Maldague, X., Infrared thermography processing based on higher-order statistics, NDT&E Int., 2010, vol. 43, pp. 661–666. doi 10.1016/j.ndteint.2010.07.002Meola, C., Infrared thermography of masonry structures, Infrared Phys. Technol., 2007, vol. 49, no. 3, pp. 228–33. doi 10.1016/j.infraredPosta, J., Dolejs, J., Non-destructive assessment of timber elements with an emphasis on radiometry., Intern. J. Arch. Herit., 2015, vol. 9, no.6.Válek, J., Kruschwitz, S., Wöstmann, J., Kind, T., Valach, J., Köpp, C., and Lesák, J., Nondestructive investigation of wet building material: Multimethodological approach, J. of performance of Constructed Facilities, pp. 462–472. doi 10.1061/(ASCE)CF.1943-5509.000005
    corecore