159 research outputs found

    Time-Resolved Studies of a Rolled-Up Semiconductor Microtube Laser

    Full text link
    We report on lasing in rolled-up microtube resonators. Time-resolved studies on these semiconductor lasers containing GaAs quantum wells as optical gain material reveal particularly fast turn-on-times and short pulse emissions above the threshold. We observe a strong red-shift of the laser mode during the pulse emission which is compared to the time evolution of the charge-carrier density calculated by rate equations

    Gate control of low-temperature spin dynamics in two-dimensional hole systems

    Full text link
    We have investigated spin and carrier dynamics of resident holes in high-mobility two-dimensional hole systems in GaAs/Al0.3_{0.3}Ga0.7_{0.7}As single quantum wells at temperatures down to 400 mK. Time-resolved Faraday and Kerr rotation, as well as time-resolved photoluminescence spectroscopy are utilized in our study. We observe long-lived hole spin dynamics that are strongly temperature dependent, indicating that in-plane localization is crucial for hole spin coherence. By applying a gate voltage, we are able to tune the observed hole g factor by more than 50 percent. Calculations of the hole g tensor as a function of the applied bias show excellent agreement with our experimental findings.Comment: 8 pages, 7 figure

    Complete shutdown of microvascular perfusion upon hepatic cryothermia is critically dependent on local tissue temperature

    Get PDF
    Since microvascular dysfunction with complete circulatory arrest and, thus, prolongation of tissue ischaemia is considered a potential mechanism for cell necrosis following hepatic cryosurgery, we determined the temperature necessary for induction of complete nutritive perfusion failure in cryothermia-treated rat livers. After localization of the cryoprobe with seven thermocouples and application of a single or double freeze–thaw cycle, in vivo fluorescence microscopy of the cryoinjured left lobe was performed over a 2-h period using a computer-controlled stepping motor, which guaranteed analysis of the identical liver tissue segments with exact allocation of the thermocouples and thus determination of tissue temperature. Cryothermia resulted in a central non-perfused part of injury, surrounded by a heterogeneously perfused peripheral zone. The non-perfused area after single and double freezing continuously increased over the first 90-min period due to a successive shutdown of perfusion within the peripheral border zone. Analysis of the thermocouples' temperature at the end of freezing revealed the 0°C-front at 11.7 mm (single freeze–thaw cycle) and 12.1 mm (double freeze–thaw cycle) distant from the centre of the cryoprobe, which exactly corresponds with the initial (30 min) expansion of the area with nutritive perfusion failure. The increased non-perfused tissue area at 2 h conformed a critical border temperature between 8.29 ± 1.63°C and 9.07 ± 0.24°C. From these findings, we conclude that freezing of liver tissue to temperatures of at least < 0°C causes complete/irreversible perfusion failure, which consequently will result in cell death and tissue necrosis, and may thus be supposed as a prerequisite for the safe and successful application of cryosurgery in hepatic tumour ablation. © 2000 Cancer Research Campaig

    &lt;i&gt;Introduction&lt;/i&gt;The Cluster mission

    Get PDF

    A seesaw-lever force-balancing suspension design for space and terrestrial gravity-gradient sensing

    Get PDF
    We present the design, fabrication, and characterization of a seesaw-lever force-balancing suspension for a silicon gravity-gradient sensor, a gravity gradiometer, that is capable of operation over a range of gravity from 0 to 1 g. This allows for both air and space deployment after ground validation. An overall rationale for designing a microelectromechanical systems(MEMS) gravity gradiometer is developed, indicating that a gravity gradiometer based on a torsion-balance, rather than a differential-accelerometer, provides the best approach. The fundamental micromachined element, a seesaw-lever force-balancing suspension, is designed with a low fundamental frequency for in-plane rotation to response gravity gradient but with good rejection of all cross-axis modes. During operation under 1 g, a gravitational force is axially loaded on two straight-beams that perform as a stiff fulcrum for the mass-connection lever without affecting sensitive in-plane rotational sensing. The dynamics of this suspension are analysed by both closed-form and finite element analysis, with good agreement between the two. The suspension has been fabricated using through-wafer deep reactive-ion etching and the dynamics verified both in air and vacuum. The sensitivity of a gravity gradiometer built around this suspension will be dominated by thermal noise, contributing in this case a noise floor of around 10 E/Hz−−−√10 E/Hz (1 E = 10−9/s2) in vacuum. Compared with previous conventional gravity gradiometers, this suspension allows a gradiometer of performance within an order of magnitude but greatly reduced volume and weight. Compared with previous MEMS gravity gradiometers, our design has the advantage of functionality under Earth gravity

    Spacecraft potential control for Double Star

    No full text
    International audienceThe spacecraft potential of Double Star TC-1 is positive in large parts of the orbits due to the photo-effect from solar EUV irradiation. These positive potentials typically disturb low energy plasma measurements on board. The potential can be reduced, and thereby the particle measurements improved, by emitting a positive ion beam. This method has successfully been applied on several other spacecraft and it has also been chosen for TC-1. The instrument TC-1/ASPOC is a derivative of the Cluster/ASPOC instruments, from which it has inherited many features. The paper describes the adaptations and further developments made for the ion emitters and the electronics. The instrument performs very well and can support higher beam currents than on Cluster. The expected significant improvement of the low energy particle measurements on board was indeed observed. The modifications of the electron distributions are analysed for a one-time interval when the spacecraft was located in the magnetosheath. The change in the potential due to the ion beam was determined, and first studies of the 3-D electron distributions in response to the spacecraft potential control have been performed, which indicate that the method works as expected

    Bone marrow mesenchymal stem cells do not enhance intra-synovial tendon healing despite engraftment and homing to niches within the synovium

    Get PDF
    Intra-synovial tendon injuries display poor healing, which often results in reduced functionality and pain. A lack of effective therapeutic options has led to experimental approaches to augment natural tendon repair with autologous mesenchymal stem cells (MSCs) although the effects of the intra-synovial environment on the distribution, engraftment and functionality of implanted MSCs is not known. This study utilised a novel sheep model which, although in an anatomically different location, more accurately mimics the mechanical and synovial environment of the human rotator cuff, to determine the effects of intra-synovial implantation of MSCs

    Active spacecraft potential control for Cluster ? implementation and first results

    No full text
    International audienceElectrostatic charging of a spacecraft modifies the distribution of electrons and ions before the particles enter the sensors mounted on the spacecraft body. The floating potential of magnetospheric satellites in sunlight very often reaches several tens of volts, making measurements of the cold (several eV) component of the ambient ions impossible. The plasma electron data become contaminated by large fluxes of photoelectrons attracted back into the sensors. The Cluster spacecraft are equipped with emitters of the liquid metal ion source type, producing indium ions at 5 to 9 keV energy at currents of some tens of microampere. This current shifts the equilibrium potential of the spacecraft to moderately positive values. The design and principles of the operation of the instrument for active spacecraft potential control (ASPOC) are presented in detail. Experience with spacecraft potential control from the commissioning phase and the first two months of the operational phase are now available. The instrument is operated with constant ion current for most of the time, but tests have been carried out with varying currents and a "feedback" mode with the instrument EFW, which measures the spacecraft potential . That has been reduced to values according to expectations. In addition, the low energy electron measurements show substantially reduced fluxes of photoelectrons as expected. The flux decrease in photoelectrons returning to the spacecraft, however, occurs at the expense of an enlarged sheath around the spacecraft which causes problems for boom-mounted probes
    • …
    corecore