184 research outputs found

    Optimization and Dose Estimation of Aerosol Delivery to Non-Human Primates

    Get PDF
    Background: In pre-clinical animal studies, the uniformity of dosing across subjects and routes of administration is a crucial requirement. In preparation for a study in which aerosolized live-attenuated measles virus vaccine was administered to cynomolgus monkeys (Macaca fascicularis) by inhalation, we assessed the percentage of a nebulized dose inhaled under varying conditions. Methods: Drug delivery varies with breathing parameters. Therefore we determined macaque breathing patterns (tidal volume, breathing frequency, and inspiratory to expiratory (I:E) ratio) across a range of 3.3-6.5 kg body weight, using a pediatric pneumotachometer interfaced either with an endotracheal tube or a facemask. Subsequently, these breathing patterns were reproduced using a breathing simulator attached to a filter to collect the inhaled dose. Albuterol was nebulized using a vibrating mesh nebulizer and the percentage inhaled dose was determined by extraction of drug from the filter and subsequent quantification. Results: Tidal volumes ranged from 24 to 46 mL, breathing frequencies from 19 to 31 breaths per minute and I: E ratios from 0.7 to 1.6. A small pediatric resuscitation mask was identified as the best fitting interface between animal and pneumotachometer. The average efficiency of inhaled dose delivery was 32.1% (standard deviation 7.5, range 24%-48%), with variation in tidal volumes as the most important determinant. Conclusions: Studies in non-human primates aimed at comparing aerosol delivery with other routes of administration should take both the inter-subject variation and relatively low efficiency of delivery to these low body weight mammals into account

    Pharmacist provision of primary health care: a modified Delphi validation of pharmacists' competencies

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Pharmacists have expanded their roles and responsibilities as a result of primary health care reform. There is currently no consensus on the core competencies for pharmacists working in these evolving practices. The aim of this study was to develop and validate competencies for pharmacists' effective performance in these roles, and in so doing, document the perceived contribution of pharmacists providing collaborative primary health care services.</p> <p>Methods</p> <p>Using a modified Delphi process including assessing perception of the frequency and criticality of performing tasks, we validated competencies important to primary health care pharmacists practising across Canada.</p> <p>Results</p> <p>Ten key informants contributed to competency drafting; thirty-three expert pharmacists replied to a second round survey. The final primary health care pharmacist competencies consisted of 34 elements and 153 sub-elements organized in seven CanMeds-based domains. Highest importance rankings were allocated to the domains of care provider and professional, followed by communicator and collaborator, with the lower importance rankings relatively equally distributed across the manager, advocate and scholar domains.</p> <p>Conclusions</p> <p>Expert pharmacists working in primary health care estimated their most important responsibilities to be related to direct patient care. Competencies that underlie and are required for successful fulfillment of these patient care responsibilities, such as those related to communication, collaboration and professionalism were also highly ranked. These ranked competencies can be used to help pharmacists understand their potential roles in these evolving practices, to help other health care professionals learn about pharmacists' contributions to primary health care, to establish standards and performance indicators, and to prioritize supports and education to maximize effectiveness in this role.</p

    Aerosol delivery to ventilated newborn infants: historical challenges and new directions

    Get PDF
    There are several aerosolized drugs which have been used in the treatment of neonatal respiratory illnesses, such as bronchodilators, diuretics, and surfactants. Preclinical in vitro and in vivo studies identified a number of variables that affect aerosol efficiency, including particle size, aerosol flows, nebulizer choice, and placement. Nevertheless, an optimized aerosol drug delivery system for mechanically ventilated infants still does not exist. Increasing interest in this form of drug delivery requires more controlled and focused research of drug/device combinations appropriate for the neonatal population. In the present article, we review the research that has been conducted thus far and discuss the next steps in developing the optimal aerosol delivery system for use in mechanically ventilated neonates

    Mathematical Properties of a New Levin-Type Sequence Transformation Introduced by \v{C}\'{\i}\v{z}ek, Zamastil, and Sk\'{a}la. I. Algebraic Theory

    Full text link
    \v{C}\'{\i}\v{z}ek, Zamastil, and Sk\'{a}la [J. Math. Phys. \textbf{44}, 962 - 968 (2003)] introduced in connection with the summation of the divergent perturbation expansion of the hydrogen atom in an external magnetic field a new sequence transformation which uses as input data not only the elements of a sequence {sn}n=0\{s_n \}_{n=0}^{\infty} of partial sums, but also explicit estimates {ωn}n=0\{\omega_n \}_{n=0}^{\infty} for the truncation errors. The explicit incorporation of the information contained in the truncation error estimates makes this and related transformations potentially much more powerful than for instance Pad\'{e} approximants. Special cases of the new transformation are sequence transformations introduced by Levin [Int. J. Comput. Math. B \textbf{3}, 371 - 388 (1973)] and Weniger [Comput. Phys. Rep. \textbf{10}, 189 - 371 (1989), Sections 7 -9; Numer. Algor. \textbf{3}, 477 - 486 (1992)] and also a variant of Richardson extrapolation [Phil. Trans. Roy. Soc. London A \textbf{226}, 299 - 349 (1927)]. The algebraic theory of these transformations - explicit expressions, recurrence formulas, explicit expressions in the case of special remainder estimates, and asymptotic order estimates satisfied by rational approximants to power series - is formulated in terms of hitherto unknown mathematical properties of the new transformation introduced by \v{C}\'{\i}\v{z}ek, Zamastil, and Sk\'{a}la. This leads to a considerable formal simplification and unification.Comment: 41 + ii pages, LaTeX2e, 0 figures. Submitted to Journal of Mathematical Physic

    Inhalation Therapy in Patients Receiving Mechanical Ventilation: An Update

    Get PDF
    Incremental gains in understanding the influence of various factors on aerosol delivery in concert with technological advancements over the past 2 decades have fueled an ever burgeoning literature on aerosol therapy during mechanical ventilation. In-line use of pressurized metered-dose inhalers (pMDIs) and nebulizers is influenced by a host of factors, some of which are unique to ventilator-supported patients. This article reviews the impact of various factors on aerosol delivery with pMDIs and nebulizers, and elucidates the correlation between in-vitro estimates and in-vivo measurement of aerosol deposition in the lung. Aerosolized bronchodilator therapy with pMDIs and nebulizers is commonly employed in intensive care units (ICUs), and bronchodilators are among the most frequently used therapies in mechanically ventilated patients. The use of inhaled bronchodilators is not restricted to mechanically ventilated patients with chronic obstructive pulmonary disease (COPD) and asthma, as they are routinely employed in other ventilator-dependent patients without confirmed airflow obstruction. The efficacy and safety of bronchodilator therapy has generated a great deal of interest in employing other inhaled therapies, such as surfactant, antibiotics, prostacyclins, diuretics, anticoagulants and mucoactive agents, among others, in attempts to improve outcomes in critically ill ICU patients receiving mechanical ventilation

    Mucociliary and long-term particle clearance in airways of patients with immotile cilia

    Get PDF
    Spherical monodisperse ferromagnetic iron oxide particles of 1.9 μm geometric and 4.2 μm aerodynamic diameter were inhaled by seven patients with primary ciliary dyskinesia (PCD) using the shallow bolus technique, and compared to 13 healthy non-smokers (NS) from a previous study. The bolus penetration front depth was limiting to the phase1 dead space volume. In PCD patients deposition was 58+/-8 % after 8 s breath holding time. Particle retention was measured by the magnetopneumographic method over a period of nine months. Particle clearance from the airways showed a fast and a slow phase. In PCD patients airway clearance was retarded and prolonged, 42+/-12 % followed the fast phase with a mean half time of 16.8+/-8.6 hours. The remaining fraction was cleared slowly with a half time of 121+/-25 days. In healthy NS 49+/-9 % of particles were cleared in the fast phase with a mean half time of 3.0+/-1.6 hours, characteristic of an intact mucociliary clearance. There was no difference in the slow clearance phase between PCD patients and healthy NS. Despite non-functioning cilia the effectiveness of airway clearance in PCD patients is comparable to healthy NS, with a prolonged kinetics of one week, which may primarily reflect the effectiveness of cough clearance. This prolonged airway clearance allows longer residence times of bacteria and viruses in the airways and may be one reason for increased frequency of infections in PCD patients

    Community based intervention to optimize osteoporosis management: randomized controlled trial

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Osteoporosis-related fractures are a significant public health concern. Interventions that increase detection and treatment of osteoporosis are underutilized. This pragmatic randomised study was done to evaluate the impact of a multifaceted community-based care program aimed at optimizing evidence-based management in patients at risk for osteoporosis and fractures.</p> <p>Methods</p> <p>This was a 12-month randomized trial performed in Ontario, Canada. Eligible patients were community-dwelling, aged ≥55 years, and identified to be at risk for osteoporosis-related fractures. Two hundred and one patients were allocated to the intervention group or to usual care. Components of the intervention were directed towards primary care physicians and patients and included facilitated bone mineral density testing, patient education and patient-specific recommendations for osteoporosis treatment. The primary outcome was the implementation of appropriate osteoporosis management.</p> <p>Results</p> <p>101 patients were allocated to intervention and 100 to control. Mean age of participants was 71.9 ± 7.2 years and 94% were women. Pharmacological treatment (alendronate, risedronate, or raloxifene) for osteoporosis was increased by 29% compared to usual care (56% [29/52] vs. 27% [16/60]; relative risk [RR] 2.09, 95% confidence interval [CI] 1.29 to 3.40). More individuals in the intervention group were taking calcium (54% [54/101] vs. 20% [20/100]; RR 2.67, 95% CI 1.74 to 4.12) and vitamin D (33% [33/101] vs. 20% [20/100]; RR 1.63, 95% CI 1.01 to 2.65).</p> <p>Conclusions</p> <p>A multi-faceted community-based intervention improved management of osteoporosis in high risk patients compared with usual care.</p> <p>Trial Registration</p> <p>This trial has been registered with clinicaltrials.gov (ID: NCT00465387)</p

    Performance Characteristics of Breezhaler((R)) and Aerolizer((R)) in the Real-World Setting

    Get PDF
    The evaluation of errors in use with different inhaler devices is challenging to quantify as there are a number of definitions of critical and non-critical errors with respect to inhaler use; in addition, performance characteristics of the device, such as airflow resistance, can also influence effective use in the real-world setting. Repeated observations and checking/correcting inhaler use are essential to optimise clinical effectiveness of inhaled therapy in patients. Breezhaler® is a single unit-dose dry powder inhaler used in chronic obstructive pulmonary disease and in asthma (budesonide) that has low airflow resistance, making it easier for patients of varying disease severities to achieve the inhalation flow rate required for lung deposition of treatment. Similar to Breezhaler®, the Aerolizer® is a single unit-dose dry powder inhaler used in asthma management with low airflow resistance. Studies have shown relatively low rates of critical errors with Breezhaler® and Aerolizer®, with similarities in the critical errors reported; these data on critical errors together with similarities in the usability of Breezhaler® and Aerolizer® further support the functional similarity between the two devices in both asthma and chronic obstructive pulmonary disease. Breezhaler® also has patient-feedback features, including use of a transparent drug capsule that can be checked after inhalation to see it is empty. The low resistance of the dose-confirming Breezhaler® results in less inspiratory effort being required by patients for its effective use, which allows the device to be used effectively across a wide age range of patients and disease severities

    Minimizing Variability of Cascade Impaction Measurements in Inhalers and Nebulizers

    Get PDF
    The purpose of this article is to catalogue in a systematic way the available information about factors that may influence the outcome and variability of cascade impactor (CI) measurements of pharmaceutical aerosols for inhalation, such as those obtained from metered dose inhalers (MDIs), dry powder inhalers (DPIs) or products for nebulization; and to suggest ways to minimize the influence of such factors. To accomplish this task, the authors constructed a cause-and-effect Ishikawa diagram for a CI measurement and considered the influence of each root cause based on industry experience and thorough literature review. The results illustrate the intricate network of underlying causes of CI variability, with the potential for several multi-way statistical interactions. It was also found that significantly more quantitative information exists about impactor-related causes than about operator-derived influences, the contribution of drug assay methodology and product-related causes, suggesting a need for further research in those areas. The understanding and awareness of all these factors should aid in the development of optimized CI methods and appropriate quality control measures for aerodynamic particle size distribution (APSD) of pharmaceutical aerosols, in line with the current regulatory initiatives involving quality-by-design (QbD)
    corecore