2,260 research outputs found

    Frequency locking to a high-finesse Fabry-Perot cavity of a Frequency doubled Nd:YAG laser used as the optical phase modulator

    Get PDF
    We report on the frequency locking of a frequency doubled Nd:YAG laser to a 45 000 finesse, 87-cm-long, Fabry-Perot cavity using a modified form of the Pound-Drever-Hall technique. Necessary signals, such as light phase modulation and frequency correction feedback, are fed direcly to the infrared pump laser. This is sufficient to achieve a stable locking of the 532 nm visible beam to the cavity, also showing that the doubling process does not degrade laser performances.Comment: submitted to Review of Scientific Instrument

    Optical Fibres Contactless Sensor for Dynamic Testing of Lightweight Structures

    Get PDF
    With dynamic testing, engineers describe activities focused on the identification of some properties of vibrating structures. This step requires for the measurements of excitations and responses signals, applying appropriate sensors directly on the test article. These instruments modify the system's mass and stiffness distributions and eventually the eigen-properties of the structure. These errors become unacceptable especially when testing lightweight structures. This paper shows the results of some tests performed on a small compressor with the purpose of identifying the blades' natural frequencies and modes. It compares the acquisitions performed with standard accelerometers and two different contact-less systems using as exciters either a micro-hammer or a micro inertial shaker. The paper shows how the contact-less sensors provide good quality data and consistent results in the mode identification phase

    Preparation and Cyclization of Some B-Keto-Y-Phthalimidoaliphatic Esters

    Get PDF
    The preparation of (a.-phthalimidoacyl)malonates via mixed anhydrides (Ila, b) and subsequent monodeethoxycarbonylation into the (a.-phthalimidoacyl)acetates (IVa, b) is described. Cyclization ·of (Illa) with hydroxylamine led to 3-(phthalimidomethyl)isoxazolin- 5-one-4-carboxylic acid (VI), while the malonate derivative (IIIb), when reacted with hydrazine, gave 4-ethoxycarbonyl-3-(a.-phthalimidoethyl) pyrazolin-5-one (VII). The ketalization of ethyl (phthalimidoacetyl) acetate (!Va) with methyl orthoformate gave methyl (phthalimidoacetyl)acetate dimethyl ketal (V). The structure of the obtained compounds is discussed on the basis of their 1H nuclear magnetic resonance spectra, in some cases supported by infrared data

    Preparation and Cyclization of Some B-Keto-Y-Phthalimidoaliphatic Esters

    Get PDF
    The preparation of (a.-phthalimidoacyl)malonates via mixed anhydrides (Ila, b) and subsequent monodeethoxycarbonylation into the (a.-phthalimidoacyl)acetates (IVa, b) is described. Cyclization ·of (Illa) with hydroxylamine led to 3-(phthalimidomethyl)isoxazolin- 5-one-4-carboxylic acid (VI), while the malonate derivative (IIIb), when reacted with hydrazine, gave 4-ethoxycarbonyl-3-(a.-phthalimidoethyl) pyrazolin-5-one (VII). The ketalization of ethyl (phthalimidoacetyl) acetate (!Va) with methyl orthoformate gave methyl (phthalimidoacetyl)acetate dimethyl ketal (V). The structure of the obtained compounds is discussed on the basis of their 1H nuclear magnetic resonance spectra, in some cases supported by infrared data

    Acoustic comfort depends on the psychological state of the individual

    Get PDF
    Recent studies have shown that comfort can be influenced more by psychological processes than from the characteristics of environmental stimulation. This is relevant for different industrial sectors, where comfort is defined only as a function of the intensity of external stimuli. In the present study, we measured physiological and psychological comfort during the exposure to four levels of acoustic noise [from 45 to 55 dB(A)] corresponding to different comfort classes inside a full-scale mock-up of a cruise ship cabin. We found an increase of psychological and physiological discomfort for higher noise intensities, but not for all the intensities defining the comfort classes. Furthermore, we found that negative psychological states determine a lower physiological sensitivity to acoustic noise variations compared to positive states. Our results show that, at normal/low intensities, psychological processes have a greater role in determining acoustic comfort when compared to the stimulus intensity. Practitioner Summary: This study shows that psychological factors can be more relevant in determining acoustic comfort inside a ship cabin than the intensity of acoustic stimulus itself. This finding suggests that the cruise industry should consider not only the engineering measurements when evaluating comfort on board, but also the passenger\u2019 psychological state. Abbreviations: AIC: akaike information criterion; CCT: colour correlated temperature; cd/m2: candela/square meters; df: degrees of freedom; F-test: Fisher's test; HF: high frequency; HR: heart rate; HRV: heart rate variability; HSV: hue saturation value; K: kelvin; LF: low frequency; LF/HF: low frequency to high frequency ratio; lme: linear mixed effects; ms: milliseconds; nu: normalized unit; p: p value; pNN50: percentage of adjacent pairs of normal to normal RR intervals differing by more than 50 milliseconds; r2: coefficient of determination; rc: concordance correlation coefficient; RMSSD: square root of the mean normal to normal RR interval; SD: standard deviation; SDNN: standard deviation of normal to normal RR intervals; SEM: standard error of the mean; t-test: student's tests; \u3c72: chi-square test

    Experimental observation of optical rotation generated in vacuum by a magnetic field

    Get PDF
    We report the experimental observation of a light polarization rotation in vacuum in the presence of a transverse magnetic field. Assuming that data distribution is Gaussian, the average measured rotation is (3.9+/-0.5)e-12 rad/pass, at 5 T with 44000 passes through a 1m long magnet, with lambda = 1064 nm. The relevance of this result in terms of the existence of a light, neutral, spin-zero particle is discussed.Comment: 11 pages, 4 figures, submitted to Physical Review Letters Comment to version 2: minor changes to abstract and final discussion. Added 2 references Comment to version 3: corrected minor typographical errors, eliminated the distinction between scalar and pseudoscalar in the particle interpretation of the resul

    Ultrafast Resonant Polarization Interferometry: Towards the First Direct Detection of Vacuum Polarization

    Full text link
    Vacuum polarization, an effect predicted nearly 70 years ago, is still yet to be directly detected despite significant experimental effort. Previous attempts have made use of large liquid-helium cooled electromagnets which inadvertently generate spurious signals that mask the desired signal. We present a novel approach for the ultra-sensitive detection of optical birefringence that can be usefully applied to a laboratory detection of vacuum polarization. The new technique has a predicted birefringence measurement sensitivity of Δn1020\Delta n \sim 10^{20} in a 1 second measurement. When combined with the extreme polarizing fields achievable in this design we predict that a vacuum polarization signal will be seen in a measurement of just a few days in duration.Comment: 9 pages, 2 figures. submitted to PR

    Optical production and detection of dark matter candidates

    Get PDF
    The PVLAS collaboration is at present running, at the Laboratori Nazionali di Legnaro of I.N.F.N., Padova, Italy, a very sensitive optical ellipsometer capable of measuring the small rotations or ellipticities which can be acquired by a linearly polarized laser beam propagating in vacuum through a transverse magnetic feld (vacuum magnetic birefringence). The apparatus will also be able to set new limits on mass and coupling constant of light scalar/pseudoscalar particles coupling to two photons by both producing and detecting the hypothetical particles. The axion, introduced to explain parity conservation in strong interactions, is an example of this class of particles, all of which are considered possible dark matter candidates. The PVLAS apparatus consists of a very high finesse (> 140000), 6.4 m long, Fabry-Perot cavity immersed in an intense dipolar magnetic field (~6.5 T). A linearly polarized laser beam is frequency locked to the cavity and analysed, using a heterodyne technique, for rotation and/or ellipticity acquired within the magnetic field.Comment: presented at "Frontier Detectors for Frontier Physics - 8th Pisa Meeting on Advanced Detectors - May 21-27, 2000" to appear in: Nucl.Instr. and Meth.

    New PVLAS results and limits on magnetically induced optical rotation and ellipticity in vacuum

    Full text link
    IIn 2006 the PVLAS collaboration reported the observation of an optical rotation generated in vacuum by a magnetic field. To further check against possible instrumental artifacts several upgrades to the PVLAS apparatus have been made during the last year. Two data taking runs, at the wavelength of 1064 nm, have been performed in the new configuration with magnetic field strengths of 2.3 T and 5 T. The 2.3 T field value was chosen in order to avoid stray fields. The new observations do not show the presence of a rotation signal down to the levels of 1.21081.2\cdot 10^{-8} rad at 5 T and 1.01081.0\cdot 10^{-8} rad at 2.3 T (at 95% c.l.) with 45000 passes in the magnetic field zone. In the same conditions no ellipticity signal was detected down to 1.41081.4\cdot 10^{-8} at 2.3 T (at 95% c.l.), whereas at 5 T a signal is still present. The physical nature of this ellipticity as due to an effect depending on B2B^2 can be excluded by the measurement at 2.3 T. These new results completely exclude the previously published magnetically induced vacuum dichroism results, indicating that they were instrumental artifacts. These new results therefore also exclude the particle interpretation of the previous PVLAS results as due to a spin zero boson. The background ellipticity at 2.3 T can be used to determine a new limit on the total photon-photon scattering cross section of σγγ<4.51034\sigma_{\gamma\gamma} < 4.5 \cdot10^{-34} barn at 95% c.l..Comment: 25 pages, 7 figures Main changes rel. to v.2: minor changes to abstract, replaced Figures 4,5,6, corrected typographical errors. Paper submitted to Physical Review

    Limits on Low Energy Photon-Photon Scattering from an Experiment on Magnetic Vacuum Birefringence

    Full text link
    Experimental bounds on induced vacuum magnetic birefringence can be used to improve present photon-photon scattering limits in the electronvolt energy range. Measurements with the PVLAS apparatus (E. Zavattini {\it et al.}, Phys. Rev. D {\bf77} (2008) 032006) at both λ=1064\lambda = 1064 nm and 532 nm lead to bounds on the parameter {\it Ae_{e}}, describing non linear effects in QED, of Ae(1064)<6.61021A_{e}^{(1064)} < 6.6\cdot10^{-21} T2^{-2} @ 1064 nm and Ae(532)<6.31021A_{e}^{(532)} < 6.3\cdot10^{-21} T2^{-2} @ 532 nm, respectively, at 95% confidence level, compared to the predicted value of Ae=1.321024A_{e}=1.32\cdot10^{-24} T2^{-2}. The total photon-photon scattering cross section may also be expressed in terms of AeA_e, setting bounds for unpolarized light of σγγ(1064)<4.61062\sigma_{\gamma\gamma}^{(1064)} < 4.6\cdot10^{-62} m2^{2} and σγγ(532)<2.71060\sigma_{\gamma\gamma}^{(532)} < 2.7\cdot10^{-60} m2^{2}. Compared to the expected QED scattering cross section these results are a factor of 2107\simeq2\cdot10^{7} higher and represent an improvement of a factor about 500 on previous bounds based on ellipticity measurements and of a factor of about 101010^{10} on bounds based on direct stimulated scattering measurements
    corecore