51 research outputs found

    Catheter-associated bacteremia by Mycobacterium senegalense in Korea

    Get PDF
    BACKGROUND: Rapidly growing mycobacteria is recognized as one of the causative agents of catheter-related infections, especially in immunocompromised hosts. To date, however, Mycobacterium senegalense, which was known as the principal pathogen of bovine farcy, has not been reported in human infection. CASE PRESENTATION: We describe the first case of human infection by M. senegalense, which has caused catheter-related bloodstream infection in a cancer patient in Korea. The microorganism was identified by the 16S rRNA gene, rpoB, and 16S-23S rRNA gene internal transcribed spacer (ITS) sequence analyses. CONCLUSION: Our first report of catheter-associated bacteremia caused by M. senegalense suggests the zoonotic nature of this species and indicates the expansion of mycobacterial species relating to human infection. M. senegalense should be considered as one of the causes of human infections in the clinical practice

    Multilaboratory Evaluation of a Viability Assay for Measurement of Opsonophagocytic Antibodies Specific to the Capsular Polysaccharides of Streptococcus pneumoniae

    No full text
    Opsonophagocytosis is a correlate of protection that measures the functional activity of vaccine-induced antibodies. A standardized opsonophagocytosis assay (OPA) should be used as part of the evaluation of current and future pneumococcal (Pnc) polysaccharide (Ps)-based vaccines. We enrolled five laboratories to evaluate a previously standardized viability OPA. Each laboratory was provided with a detailed OPA protocol, seven target Pnc strains (serotypes 4, 6B, 9V, 14, 18C, 19F, and 23F), two quality control sera and 12 paired sera (blinded) from adult donors who received one dose of the 23-valent Pnc Ps vaccine. Laboratories sent their results to the Centers for Disease Control and Prevention for analysis. Sera were tested in duplicate (single run), and the results were averaged to yield a single OPA titer (≥50% killing) for each serum sample. The percentage of sera within one or two dilutions of the calculated median OPA titer was determined for each laboratory and for each serotype. In general, laboratories were capable of detecting OPA titers within one or two dilutions of the median for at least 75 and 88%, respectively, of the sera tested. The level of agreement with the median OPA titers varied depending on the participating laboratory (overall agreement = 0.8 [99% confidence interval = 0.75 to 0.85]). All OPA median titers reported for quality control sera were within one dilution of the expected titer. We conclude that this OPA can be done in multiple laboratories with a high degree of interlaboratory reproducibility
    • …
    corecore