66 research outputs found

    Dimensional changes of CAD/CAM polymer crowns after water aging - An in vitro experiment

    Get PDF
    Computer-Aided Design/Computer-Aided Manufacturing (CAD/CAM) polymers can potentially replace traditional materials used for manufacturing indirect restorations. In 2012, Lava Ultimate (LU) was introduced as a highly suitable material for implant-supported single crowns. Three years after its introduction, the manufacturer issued a change in indication for the material, implying that they no longer considered the material to be suitable for crown indications due to debonding issues. A clinical trial with implant-borne Lava Ultimate crowns bonded to zirconia abutments revealed that 80 percent of the LU crowns showed debonding from the abutment within one year, whereas no debonding occurred when an alternative full-ceramic restoration material was used. These results suggest that the material itself had been the cause of the debonding. However, the exact reason for the debonding remained unclear. Water uptake in resin methacrylates like LU is known to cause dimensional changes resulting in mechanical stress on the RelyX Ultimate (RU) cement. The purpose of this study is to quantify the dimensional changes in LU caused by water uptake and relate these dimensional changes to the failure of the RU cement. Twenty-five identical LU-crowns were divided into three groups. 10 LU-crowns with abutment and 10 crowns without abutments were stored in water for 23 days and were only removed for measurement. Five crowns served as a control to calibrate the measurements. The internal diameter was measured eight times with a TS 460 Heidenhain touch probe. For visualization purposes, one crown was also 3D scanned before and after water treatment. The results showed that after 23 days in water the mean increase in diameter for the groups with and without abutment was 36.6 μm (SD = 35,1) and 36.7 μm (SD = 26,5) respectively. Mixed effects modelling indicated no significant between-group differences at any time point. Exposure of LU to water results in dimensional changes causing mechanical stress on the crown-abutment complex. It can be estimated that RU cement fails after an expansion of more than 4 μm. Within the limitations of this in vitro study, it can be concluded that the dimensional changes induced by water uptake can cause debonding issues. As more CAD/CAM polymers for restorative purposes are expected to be developed, the results of this study should stimulate manufacturers to quantify their products' dimensional changes in a wet environment before market release

    Influence of Deep Margin Elevation and preparation design on the fracture strength of indirectly restored molars

    Get PDF
    The objectives of this in-vitro study were to investigate the influence of Deep Margin Elevation (DME) and the preparation design (cusp coverage) on the fracture strength and repairability of CAD/CAM manufactured lithium disilicate (LS2) restorations on molars. Sound extracted human molars (n = 60) were randomly divided into 4 groups (n = 15) (inlay without DME (InoD); inlay with DME (IWD); onlay without DME (OnoD); onlay with DME (OnWD)). All samples were aged (1.2 × 106 cycles of 50N, 8000 cycles of 5–55 °C) followed by oblique static loading until fracture. Fracture strength was measured in Newton and the fracture analysis was performed using a (scanning electron) microscope. Data was statistically analyzed using two-way ANOVA and contingency tables. DME did not affect the fracture strength of LS2 restorations to a statistically significant level (p =.15). Onlays were stronger compared to inlays (p =.00). DME and preparation design did not interact (p =.97). However, onlays with DME were significantly stronger than inlays without DME (p =.00). More repairable fractures were observed among inlays (p =.00). Catastrophic, crown-root fractures were more prevalent in onlays (p =.00). DME did not influence repairability of fractures or fracture types to a statistically significant level (p &gt;.05). Within the limitations of this in-vitro study, DME did not statistical significantly affect the fracture strength, nor the fracture type or repairability of LS2 restorations in molars. Cusp coverage did increase the fracture strength. However, oblique forces necessary to fracture both inlays and onlays, either with or without DME, by far exceeded the bite forces that can be expected under physiological clinical conditions. Hence, both inlays and onlays are likely to be fracture resistant during clinical service.</p

    Ceramic implants:the state of art

    Get PDF
    A multitude of biomaterials have been used for the production of implants through the years. Titanium or titanium alloy have been regarded as the 'gold standard' for years. However, potential risks and disadvantages regarding biocompatibility and aesthetics have also been reported for the use of titanium in dental implantology. As such, there is need for an alternative material. Zirconia may be regarded as a possible alternative. It is a ceramic with high fracture toughness and other positive qualities, such as beings metal-free, biocompatible, and white, which is aesthetically desirable. Short-term study results of contemporary zirconia implants are promising and comparable to titanium implants. Nevertheless, the material is relatively brittle and susceptible to surface defects. However, no long-term clinical results exists and possible complications are unknown. Long-term clinical research is needed before zirconia implants routine use may be endorsed.</p

    Surface degradation of nanocrystalline zirconia dental implants

    Get PDF
    Yttria-stabilized zirconia prepared by hot isostatic pressing represents attractive material for biomedical applications. In this work the degradation of yttria-stabilized zirconia dental implants abutments due to the tetragonal to monoclinic phase transformation after one year of clinical use was studied in detail. Microstructural characterization by Electron Back Scattering Diffraction was successfully applied. The amount and distribution of the monoclinic phase, the grain-size distribution and crystallographic orientations between tetragonal and monoclinic crystals in 3 mol.% yttria-stabilized polycrystalline zirconia were determined in two different types of abutments currently used in clinical practice. Clear crystallographic orientation relationship between parent tetragonal and daughter monoclinic phase was clearly observed. An important and novel conclusion is that no substantial bulk degradation of 3Y-TZP dental implant abutments was detected after 1 year of clinical use

    Fracture strength of various types of direct and indirect restorations in the functional repair of endodontically treated molars

    Get PDF
    The fracture strength of endodontically treated molars restored by means of various types of direct and indirect materials was studied in vitro. 105 sound molars were endodontically treated and randomly assigned to 1 control group (endodontic access cavity only) and 6 experimental groups (n = 15) with restorations of the following materials: glass fibre reinforced composite (GFRC); microhybrid composite (C); microhybrid composite restoration with glass fiber post (CP); full-contour lithium disilicate crown (LDS); full-contour lithium disilicate crown with glass fiber post (P-LDS); and an endocrown (EC). Specimens were thermo-mechanically aged and axially loaded until failure. Data were analysed using ANOVA and Tukey's post hoc test (α = 0.05). Fracture strength was significantly affected by the type of restoration (p = 0.000). LDS had significantly higher fracture strength than the control group and GFRC, C and CP groups. Groups EC, LDS and P-LDS were not statistically different from each other in fracture strength. This was also the case with EC, P-LDS and all composite groups. The glass fibre strength of composite restoration resulted in significantly fewer fatal fractures.</p

    Therapeutic implications of improved molecular diagnostics for rare CNS-embryonal tumor entities: results of an international, retrospective study

    Get PDF
    BACKGROUND: Only few data are available on treatment-associated behavior of distinct rare CNS-embryonal tumor entities previously treated as "CNS-primitive neuroectodermal tumors" (CNS-PNET). Respective data on specific entities, including CNS neuroblastoma, FOXR2 activated (CNS NB-FOXR2), and embryonal tumor with multi-layered rosettes (ETMR) are needed for development of differentiated treatment strategies. METHODS: Within this retrospective, international study, tumor samples of clinically well-annotated patients with the original diagnosis of CNS-PNET were analyzed using DNA methylation arrays (n=307). Additional cases (n=66) with DNA methylation pattern of CNS NB-FOXR2 were included irrespective of initial histological diagnosis. Pooled clinical data (n=292) were descriptively analyzed. RESULTS: DNA methylation profiling of "CNS-PNET" classified 58(19%) cases as ETMR, 57(19%) as HGG, 36(12%) as CNS NB-FOXR2, and 89(29%) cases were classified into 18 other entities. Sixty-seven (22%) cases did not show DNA methylation patterns similar to established CNS tumor reference classes. Best treatment results were achieved for CNS NB-FOXR2 patients (5-year PFS: 63%±7%, OS: 85%±5%, n=63), with 35/42 progression-free survivors after upfront craniospinal irradiation (CSI) and chemotherapy. The worst outcome was seen for ETMR and HGG patients with 5-year PFS of 18%±6% and 22%±7%, and 5-year OS of 24%±6% and 25%±7%, respectively. CONCLUSION: The historically reported poor outcome of CNS-PNET patients becomes highly variable when tumors are molecularly classified based on DNA methylation profiling. Patients with CNS NB-FOXR2 responded well to current treatments and a standard-risk-CSI based regimen may be prospectively evaluated. The poor outcome of ETMR across applied treatment strategies substantiates the necessity for evaluation of novel treatments

    Differences in bleeding behavior after endoscopic band ligation: a retrospective analysis

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Endoscopic band ligation (EBL) is generally accepted as the treatment of choice for bleeding from esophageal varices. It is also used for secondary prophylaxis of esophageal variceal hemorrhage. However, there is no data or guidelines concerning endoscopic control of ligation ulcers. We conducted a retrospective study of EBL procedures analyzing bleeding complications after EBL.</p> <p>Methods</p> <p>We retrospectively analyzed data from patients who underwent EBL. We analyzed several data points, including indication for the procedure, bleeding events and the time interval between EBL and bleeding.</p> <p>Results</p> <p>255 patients and 387 ligation sessions were included in the analysis. We observed an overall bleeding rate after EBL of 7.8%. Bleeding events after elective treatment (3.9%) were significantly lower than those after treatment for acute variceal hemorrhage (12.1%). The number of bleeding events from ligation ulcers and variceal rebleeding was 14 and 15, respectively. The bleeding rate from the ligation site in the group who underwent emergency ligation was 7.1% and 0.5% in the group who underwent elective ligation. Incidence of variceal rebleeding did not vary significantly. Seventy-five percent of all bleeding episodes after elective treatment occurred within four days after EBL. 20/22 of bleeding events after emergency ligation occured within 11 days after treatment. Elective EBL has a lower risk of bleeding from treatment-induced ulceration than emergency ligation.</p> <p>Conclusions</p> <p>Patients who underwent EBL for treatment of acute variceal bleeding should be kept under medical surveillance for 11 days. After elective EBL, it may be reasonable to restrict the period of surveillance to four days or even perform the procedure in an out-patient setting.</p
    corecore