1,554 research outputs found

    Complete polarization control for a nanofiber waveguide using directional coupling

    Get PDF
    Optical nanofiber waveguides are widely used for near-field delivery and measurement of light. Despite their versatility and efficiency, nanofibers have a critical drawback - their inability to maintain light's polarization state on propagation. Here, we design a directional coupler consisting of two crossed nanofibers to probe the polarization state at the waist region. Directionality of coupling occurs due to asymmetric dipolar emission or spin-locking when the evanescent field pattern breaks the mirror symmetry of the crossed-nanofiber system. We demonstrate that, by monitoring the outputs from the directional coupler, two non-orthogonal polarization states can be prepared at the nanofiber waist with a fidelity higher than 99%. Based on these states, we devise a simple and reliable method for complete control of the polarization along a nanofiber waveguide.Comment: 8 pages, 8 figure

    Symmetry and optical selection rules in graphene quantum dots

    Get PDF
    Graphene quantum dots (GQD's) have optical properties which are very different from those of an extended graphene sheet. In this Article we explore how the size, shape and edge--structure of a GQD affect its optical conductivity. Using representation theory, we derive optical selection rules for regular-shaped dots, starting from the symmetry properties of the current operator. We find that, where the x- and y-components of the current operator transform with the same irreducible representation (irrep) of the point group - for example in triangular or hexagonal GQD's - the optical conductivity is independent of the polarisation of the light. On the other hand, where these components transform with different irreps - for example in rectangular GQD's - the optical conductivity depends on the polarisation of light. We find that GQD's with non-commuting point-group operations - for example dots of rectangular shape - can be distinguished from GQD's with commuting point-group operations - for example dots of triangular or hexagonal shape - by using polarized light. We carry out explicit calculations of the optical conductivity of GQD's described by a simple tight--binding model and, for dots of intermediate size, \textcolor{blue}{(10≲L≲50 nm10 \lesssim L \lesssim 50\ \text{nm})} find an absorption peak in the low--frequency range of the spectrum which allows us to distinguish between dots with zigzag and armchair edges. We also clarify the one-dimensional nature of states at the van Hove singularity in graphene, providing a possible explanation for very high exciton-binding energies. Finally we discuss the role of atomic vacancies and shape asymmetry.Comment: 24 pages, 15 figure

    Is there a relationship between fingerprint donation and DNA shedding?

    Get PDF
    This research investigates the possible relationship between fingerprint donation and DNA shedding. Volunteers were asked to provide a series of fingerprint depletions on glass. The level of fingerprint detail developed and DNA profiling results obtained were compared for each donor to investigate whether a relationship between fingerprint donation and DNA shedding exists. Our results suggest that between comparisons of donors, there is no statistical difference between the left and right hand of our volunteers in terms of fingerprint donation, but there is a statistical difference in terms of DNA shedding with three of our eight donors. Our results also indicate that there is no correlation between fingerprint donation and DNA shedding, meaning that an enhanced fingerprint with full ridge detail will not necessarily give a full DNA profile. In serious crime, these two avenues of evidence must be explored

    Blockade of alpha 2-adrenergic receptors in prelimbic cortex: impact on cocaine self-administration in adult spontaneously hypertensive rats following adolescent atomoxetine treatment

    Get PDF
    RATIONALE: Research with the spontaneously hypertensive rat (SHR) model of attention deficit/hyperactivity disorder demonstrated that chronic methylphenidate treatment during adolescence increased cocaine self-administration established during adulthood under a progressive ratio (PR) schedule. Compared to vehicle, chronic atomoxetine treatment during adolescence failed to increase cocaine self-administration under a PR schedule in adult SHR. OBJECTIVES: We determined if enhanced noradrenergic transmission at α2-adrenergic receptors within prefrontal cortex contributes to this neutral effect of adolescent atomoxetine treatment in adult SHR. METHODS: Following treatment from postnatal days 28–55 with atomoxetine (0.3 mg/kg) or vehicle, adult male SHR and control rats from Wistar-Kyoto (WKY) and Wistar (WIS) strains were trained to self-administer 0.3 mg/kg cocaine. Self-administration performance was evaluated under a PR schedule of cocaine delivery following infusion of the α2-adrenergic receptor antagonist idazoxan (0 and 10–56 μg/side) directly into prelimbic cortex. RESULTS: Adult SHR attained higher PR break points and had greater numbers of active lever responses and infusions than WKY and WIS. Idazoxan dose-dependently increased PR break points and active lever responses in SHR following adolescent atomoxetine vs. vehicle treatment. Behavioral changes were negligible after idazoxan pretreatment in SHR following adolescent vehicle or in WKY and WIS following adolescent atomoxetine or vehicle. CONCLUSIONS: α2-Adrenergic receptor blockade in prelimbic cortex of SHR masked the expected neutral effect of adolescent atomoxetine on adult cocaine self-administration behavior. Moreover, greater efficacy of acute idazoxan challenge in adult SHR after adolescent atomoxetine relative to vehicle is consistent with the idea that chronic atomoxetine may downregulate presynaptic α2A-adrenergic autoreceptors in SHR.National Institutes of Health grant DA011716. (DA011716 - National Institutes of Health)https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5693724/Published versio

    All-Optical Nanopositioning of High-Q Silica Microspheres

    Get PDF
    A tunable, all-optical, coupling method has been realized for a high-\textit{Q} silica microsphere and an optical waveguide. By means of a novel optical nanopositioning method, induced thermal expansion of an asymmetric microsphere stem for laser powers up to 171~mW has been observed and used to fine tune the microsphere-waveguide coupling. Microcavity displacements ranging from (0.612~±\pm~0.13) -- (1.5 ±\pm 0.13) μ\mum and nanometer scale sensitivities varying from (2.81 ±\pm 0.08) -- (7.39 ±\pm 0.17) nm/mW, with an apparent linear dependency of coupling distance on stem laser heating, were obtained. Using this method, the coupling was altered such that different coupling regimes could be explored for particular samples. This tunable coupling method, in principle, could be incorporated into lab-on-a-chip microresonator systems, photonic molecule systems, and other nanopositioning frameworks.Comment: 6pages,4figure

    Bandpass transmission spectra of a whispering-gallery microcavity coupled to an ultrathin fiber

    Get PDF
    Tapered fibers with diameters ranging from 1-4 micron are widely used to excite the whispering-gallery (WG) modes of microcavities. Typically, the transmission spectrum of a WG cavity coupled to a waveguide around a resonance assumes a Lorentzian dip morphology due to resonant absorption of the light within the cavity. In this paper, we demonstrate that the transmission spectra of a WG cavity coupled with an ultrathin fiber (500-700nm) may exhibit both Lorentzian dips and peaks, depending on the gap between the fiber and the microcavity. By considering the large scattering loss of off-resonant light from the fiber within the coupling region, this phenomenon can be attributed to partially resonant light bypassing the lossy scattering region via WG modes, allowing it to be coupled both to and from the cavity, thence manifesting as Lorentzian peaks within the transmission spectra, which implies the system could be implemented within a bandpass filter framework.Comment: 4pages,6figure

    Tapered optical fibers as tools for probing magneto-optical trap characteristics

    Get PDF
    We present a novel technique for measuring the characteristics of a magneto-optical trap for cold atoms by monitoring the spontaneous emission from trapped atoms coupled into the guided mode of a tapered optical nanofiber. We show that the nanofiber is highly sensitive to very small numbers of atoms close to its surface. The size and shape of the MOT, determined by translating the cold atom cloud across the tapered fiber, is in excellent agreement with measurements obtained using the conventional method of fluorescence imaging using a CCD camera. The coupling of atomic fluorescence into the tapered fiber also allows us to monitor the loading and lifetime of the trap. The results are compared to those achieved by focusing the MOT fluorescence onto a photodiode and it was seen that the tapered fiber gives slightly longer loading and lifetime measurements due to the sensitivity of the fiber, even when very few atoms are present.Comment: 21 pages, 5 figure
    • …
    corecore