34 research outputs found

    Measurement of coronary calcium scores by electron beam computed tomography or exercise testing as initial diagnostic tool in low-risk patients with suspected coronary artery disease

    Get PDF
    We determined the efficiency of a screening protocol based on coronary calcium scores (CCS) compared with exercise testing in patients with suspected coronary artery disease (CAD), a normal ECG and troponin levels. Three-hundred-and-four patients were enrolled in a screening protocol including CCS by electron beam computed tomography (Agatston score), and exercise testing. Decision-making was based on CCS. When CCS≥400, coronary angiography (CAG) was recommended. When CCS<10, patients were discharged. Exercise tests were graded as positive, negative or nondiagnostic. The combined endpoint was defined as coronary event or obstructive CAD at CAG. During 12±4 months, CCS≥400, 10–399 and <10 were found in 42, 103 and 159 patients and the combined endpoint occurred in 24 (57%), 14 (14%) and 0 patients (0%), respectively. In 22 patients (7%), myocardial perfusion scintigraphy was performed instead of exercise testing due to the inability to perform an exercise test. A positive, nondiagnostic and negative exercise test result was found in 37, 76 and 191 patients, and the combined endpoint occurred in 11 (30%), 15 (20%) and 12 patients (6%), respectively. Receiver-operator characteristics analysis showed that the area under the curve of 0.89 (95% CI: 0.85–0.93) for CCS was superior to 0.69 (95% CI: 0.61–0.78) for exercise testing (P<0.0001). In conclusion, measurement of CCS is an appropriate initial screening test in a well-defined low-risk population with suspected CAD

    The Rotterdam Study: 2016 objectives and design update

    Full text link

    Erste Ergebnisse zur Nutzung eines web-basierten Tests auf Rehabilitationsbedarf bei Versicherten der Deutschen Rentenversicherung

    No full text
    OBJECTIVES: To investigate simultaneous dual-isotope SPECT/CT with two differently radioisotope-labelled albumin-microsphere fractions for treatment planning of hepatic radioembolisation. METHODS: In addition to (99m)Technetium-labelled albumin microspheres (commercially available), we performed labelling with (111)Indium. Binding stability of (111)Indium-labelled microspheres was tested in vitro and in vivo in mice. Simultaneous dual-isotope SPECT/CT imaging was validated in an anthropomorphic torso phantom; subsequently, dual-isotope SPECT/CT was performed under in-vivo conditions in pigs (n = 3) that underwent transarterial injection of (99m)Technetium- and (111)Indium-labelled microspheres in the liver (right and left hepatic artery, respectively), in both kidneys and in the gluteal musculature. In total, n = 18 transarterial injections were performed. RESULTS: In-vitro testing and in-vivo studies in mice documented high binding stability for both (99m)Technetium-labelled and (111)Indium-labelled microsphere fractions. In phantom studies, simultaneous dual-isotope SPECT/CT enabled reliable separation of both isotopes. In pigs, the identified deposition of both isotopes could be accurately matched with intended injection targets (100 %, 18/18 intended injection sites). Furthermore, an incidental deposition of (99m)Technetium-labelled microspheres in the stomach could be correlated to the test injection into a right hepatic artery. CONCLUSION: Simultaneous dual-isotope SPECT/CT after transarterial injection with (99m)Technetium- and (111)Indium-labelled microspheres is feasible. Thus, it may offer additional, valuable information compared to single (99m)Technetium-labelled albumin examinations. KEY POINTS: * Simultaneous dual-isotope SPECT/CT with (111) In- and (99m) Tc-labelled albumin microspheres is feasible. * Differentiation of two microsphere fractions after transarterial injection is possible. * The origin of an extra-hepatic microsphere deposition can be correlated to the corresponding artery. * This technique could reduce the setup time for selective internal radiation treatment
    corecore