87 research outputs found

    The effect of curing temperature and time on the acoustic and optical properties of PVCP

    Get PDF
    Polyvinyl chloride plastisol (PVCP) has been increasingly used as a phantom material for photoacoustic and ultrasound imaging. As one of the most useful polymeric materials for industrial applications, its mechanical properties and behaviour are well-known. Although the acoustic and optical properties of several formulations have previously been investigated, it is still unknown how these are affected by varying the fabrication method. Here, an improved and straightforward fabrication method is presented and the effect of curing temperature and curing time on PVCP acoustic and optical properties, as well as their stability over time, is investigated. Speed of sound and attenuation were determined over a frequency range from 2 to 15 MHz, while the optical attenuation spectra of samples was measured over a wavelength range from 500 to 2200 nm. Results indicate that the optimum properties are achieved at curing temperatures between 160 °C and 180 °C, while the required curing time decreases with increasing temperature. The properties of the fabricated phantoms were highly repeatable, meaning the phantoms are not sensitive to the manufacturing conditions provided the curing temperature and time are within the range of complete gelation-fusion (samples are optically clear) and below the limit of thermal degradation (indicated by the yellowish appearance of the sample). The samples’ long term stability was assessed over 16 weeks and no significant change was observed in the measured acoustic and optical properties

    Measurement of the ultrasound attenuation and dispersion in 3D-printed photopolymer materials from 1 to 3.5 MHz

    Get PDF
    Over the past decade, the range of applications in biomedical ultrasound exploiting 3D printing has rapidly expanded. For wavefront shaping specifically, 3D printing has enabled a diverse range of new, low-cost approaches for controlling acoustic fields. These methods rely on accurate knowledge of the bulk acoustic properties of the materials; however, to date, robust knowledge of these parameters is lacking for many materials that are commonly used. In this work, the acoustic properties of eight 3D-printed photopolymer materials were characterised over a frequency range from 1 to 3.5 MHz. The properties measured were the frequency-dependent phase velocity and attenuation, group velocity, signal velocity, and mass density. The materials were fabricated using two separate techniques [PolyJet and stereolithograph (SLA)], and included Agilus30, FLXA9960, FLXA9995, Formlabs Clear, RGDA8625, RGDA8630, VeroClear, and VeroWhite. The range of measured density values across all eight materials was 1120–1180 kg · m−3, while the sound speed values were between 2020 to 2630 m · s−1, and attenuation values typically in the range 3–9 dB · MHz−1· cm−1

    Venous pseudoaneurysm of the great saphenous vein stump as late complication of flush saphenofemoral ligation and stripping

    Get PDF
    Guidelines now recommend endovenous thermal ablation over open treatment of saphenous incompetence, but flush saphenofemoral ligation and stripping remain relevant when appropriately applied and expertly executed. Complications are rare but could be severe, needing further surgical correction. We report a unique case of a late venous pseudoaneurysm of the great saphenous vein stump after flush saphenofemoral ligation and stripping, successfully treated with surgical sac excision. We highlight the importance of continuous follow-up for patients previously submitted to open venous surgery

    Measurement of the temperature-dependent output of lead zirconate titanate transducers

    Get PDF
    The effect of temperature and electrical drive conditions on the output of lead zirconate titanate (PZT) transducers is of particular interest in ultrasound metrology and medical ultrasound applications. In this work, the temperature-dependent output of two single-element PZT transducers was measured between 22 °C and 46 °C. Two independent measurement methods were used, namely radiation force balance measurements and laser vibrometry. When driven at constant voltage using a 50 matched signal generator and amplifier using continuous wave (CW) or quasi-CW excitation, the output of the two transducers increased on average by 0.6% per degree, largely due to an increase in transducer efficiency with temperature. The two measurement methods showed close agreement. Similar trends were observed when using single cycle excitation with the same signal chain. However, when driven using a pulser (which is not electrically matched), the two transducers exhibited different behaviour depending on their electrical impedance. Accounting for the temperature-dependent output of PZT transducers could have implications for many areas of ultrasound metrology, for example, in therapeutic ultrasound where a coupling fluid at an increased or decreased temperature is often used

    High resolution MRI for quantitative assessment of inferior alveolar nerve impairment in course of mandible fractures: an imaging feasibility study

    Get PDF
    The purpose of this study was to evaluate a magnetic resonance imaging (MRI) protocol for direct visualization of the inferior alveolar nerve in the setting of mandibular fractures. Fifteen patients suffering from unilateral mandible fractures involving the inferior alveolar nerve (15 affected IAN and 15 unaffected IAN from contralateral side) were examined on a 3 T scanner (Elition, Philips Healthcare, Best, the Netherlands) and compared with 15 healthy volunteers (30 IAN in total). The sequence protocol consisted of a 3D STIR, 3D DESS and 3D T1 FFE sequence. Apparent nerve-muscle contrast-to-noise ratio (aNMCNR), apparent signal-to-noise ratio (aSNR), nerve diameter and fracture dislocation were evaluated by two radiologists and correlated with nerve impairment. Furthermore, dislocation as depicted by MRI was compared to computed tomography (CT) images. Patients with clinically evident nerve impairment showed a significant increase of aNMCNR, aSNR and nerve diameter compared to healthy controls and to the contralateral side (p < 0.05). Furthermore, the T1 FFE sequence allowed dislocation depiction comparable to CT. This prospective study provides a rapid imaging protocol using the 3D STIR and 3D T1 FFE sequence that can directly assess both mandible fractures and IAN damage. In patients with hypoesthesia following mandibular fractures, increased aNMCN R, aSNR and nerve diameter on MRI imaging may help identify patients with a risk of prolonged or permanent hypoesthesia at an early time

    The effect of low level laser on condylar growth during mandibular advancement in rabbits

    Get PDF
    <p>Abstract</p> <p>Introduction</p> <p>It has been shown that Low Level Laser (LLL) has a positive effect on bone formation. The aim of this study was to evaluate the effect of low level laser on condylar growth during mandibular advancement in rabbits.</p> <p>Materials and methods</p> <p>Continuous forward mandibular advancement was performed in fourteen male Albino rabbits with the mean age of 8 weeks and the mean weight of 1.5 ± 0.5 kg, with acrylic inclined planes. The rabbits were randomly assigned into two groups after 4 weeks. LLL (KLO3: wave length 630 nm) was irradiated at 3 points around the TMJ, through the skin in the first group. The exposure was performed for 3 minutes at each point (a total of 9 minutes) once a day for 3 weeks. The control group was not exposed to any irradiation. The rabbits in both groups were sacrificed after two months and the histological evaluation of TMJ was performed to compare fibrous tissue, cartilage, and new bone formation in condylar region in both groups. Disc displacement was also detected in both groups. Student's t-test, Exact Fisher and Chi square tests were used for the statistical analysis.</p> <p>Results</p> <p>The formation of fibrous tissue was significantly lower, while bone formation was significantly greater in lased group as compared with control group. The thickness of cartilage did not differ significantly between two groups.</p> <p>Conclusion</p> <p>Irradiation of LLL (KLO3) during mandibular advancement in rabbits, increases bone formation in condylar region, while neither increase in the cartilage thickness nor fibrous tissues was observed.</p

    A Case of Recurrent Multifocal Central Giant Cell Granulomas

    Get PDF
    One case of recurrent multifocal central giant cell granulomas (CGCG) is presented. Initially, the lesions presented concurrently in the maxilla and mandible with subsequent recurrence in the mandible. Now, two recurrences are seen in the maxillary sinus and ethmoid region. The literature regarding multifocal CGCG is reviewed
    corecore