47 research outputs found

    Executive Summary of the Second International Guidelines for the Diagnosis and Management of Pediatric Acute Respiratory Distress Syndrome (PALICC-2)

    Get PDF
    OBJECTIVES: We sought to update our 2015 work in the Second Pediatric Acute Lung Injury Consensus Conference (PALICC-2) guidelines for the diagnosis and management of pediatric acute respiratory distress syndrome (PARDS), considering new evidence and topic areas that were not previously addressed. DESIGN: International consensus conference series involving 52 multidisciplinary international content experts in PARDS and four methodology experts from 15 countries, using consensus conference methodology, and implementation science. SETTING: Not applicable. PATIENTS: Patients with or at risk for PARDS. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: Eleven subgroups conducted systematic or scoping reviews addressing 11 topic areas: 1) definition, incidence, and epidemiology; 2) pathobiology, severity, and risk stratification; 3) ventilatory support; 4) pulmonary-specific ancillary treatment; 5) nonpulmonary treatment; 6) monitoring; 7) noninvasive respiratory support; 8) extracorporeal support; 9) morbidity and long-term outcomes; 10) clinical informatics and data science; and 11) resource-limited settings. The search included MEDLINE, EMBASE, and CINAHL Complete (EBSCOhost) and was updated in March 2022. Grading of Recommendations, Assessment, Development, and Evaluation methodology was used to summarize evidence and develop the recommendations, which were discussed and voted on by all PALICC-2 experts. There were 146 recommendations and statements, including: 34 recommendations for clinical practice; 112 consensus-based statements with 18 on PARDS definition, 55 on good practice, seven on policy, and 32 on research. All recommendations and statements had agreement greater than 80%. CONCLUSIONS: PALICC-2 recommendations and consensus-based statements should facilitate the implementation and adherence to the best clinical practice in patients with PARDS. These results will also inform the development of future programs of research that are crucially needed to provide stronger evidence to guide the pediatric critical care teams managing these patients.</p

    C septicum

    No full text

    Women's evaluations of their experience in a multicenter randomized controlled trial of intrapartum fetal pulse oximetry (The FOREMOST Trial)

    No full text
    Caroline Crowther is listed as a member of the FOREMOST Study GroupThe definitive version is available at www.blackwell-synergy.comBackground:Fetal pulse oximetry improves the assessment of fetal well‐being during labor. The objective of this study was to evaluate women's satisfaction with their experience with this additional technology. Methods:We surveyed women participating in the FOREMOST trial, a randomized controlled trial comparing the addition of fetal pulse oximetry (FPO) to conventional cardiotocograph (CTG) monitoring (intervention group), versus CTG‐only (control group), in the presence of nonreassuring fetal status during labor. Our survey evaluated 3 aspects of women's experience: labor, fetal monitoring, and participation in the research. The survey was administered within a few days of giving birth and repeated 3 months later. Results:No differences were found between the intervention and control groups for women's evaluations of their labor, fetal monitoring, research, or overall experiences when surveyed on both occasions. Within each study group, a small but statistically significant decline occurred in women's scores for their experience of labor and overall experience from the initial survey close to the time of giving birth, to 3 months later. The magnitude of differences in responses over time was similar for the both groups. Women were more satisfied after a spontaneous or assisted vaginal birth than after cesarean section. Length of time the research midwife was present had a significant positive effect on women's ratings of their experience several days after giving birth (p = 0.006), but no effect at 3 months. Conclusions:The addition of fetal pulse oximetry for the assessment of fetal well‐being during labor did not affect childbearing women's perceptions of fetal monitoring or their labor. Women evaluated their experience in the research process positively overall. Small changes occurred in women's perception of their satisfaction over time
    corecore