28 research outputs found

    Acromion's morphological role in impingement syndrome: a prospective radiologic study

    No full text
    Aim. The purpose of this prospective study was to evaluate the acromion's morphology, which is one of the extrinsic reasons of impingement syndrome, and to examine its role on this syndrome

    Medial meniscus anterior horn cyst: Arthroscopic decompression

    No full text
    Meniscus cysts are mostly seen with meniscus tears, and arthroscopic decompression of cysts is gaining great importance in their treatment. In this study, we present a medial meniscus anterior horn cyst without an accompanying tear in the meniscus. A 33-year-old male patient was seen with pain and a palpable mass in his right knee. He complained that the severity of the pain had increased over the previous year. After the clinical and radiologic examinations, a painless, fixed soft tissue mass averaging 4 X 5 cm was located just medial to tuberositas tibia. The cyst was decompressed arthroscopically. In the 18th month of follow up, the mass had totally disappeared and the patient had no pain. Medial meniscus cysts are seen nine times fewer than lateral meniscus cysts. They are mostly accompanied with meniscal tears. Total meniscectomy with arthrotomy, isolated cyst excision, cyst excision, and partial meniscectomy with arthrotomy,and arthroscopic partial meniscectomy with cyst decompression are treatment modalities. Arthroscopic meniscal cyst decompression is an important treatment choice and should always be taken into consideration with low morbidity, short recovery period, low recurrence rate, preservation of range of motion, and permission for early mobilization and rehabilitation of the joint

    Evaluation of patellar height and measurement methods after valgus high tibial osteotomy

    No full text
    Several controversies exist regarding the surgical difficulties and the results of total knee arthroplasty performed after failed valgus high tibial osteotomy (HTO), and the main subject is the change in patellar height that results as patella baja or infera. The purpose of this retrospective study was to evaluate patellar height after valgus HTO and the measurement methods that were actually used. Eighty-five knees that were subjected to valgus HTO were evaluated both preoperatively and postoperatively according to the Insall-Salvati Index (ISI), Blackburne-Peel Index (BPI), and Caton Index (CI) to assess any alteration of patellar tendon height that was present. All cases underwent closing wedge osteotomy with three staples or plate internal fixation and were allowed early range of motion. Significant decrease in mean patellar height ratios was detected according to all three indexes at 85 months of mean follow-up. The percentages of the decrease were 8.26% in ISI, 9.08% in BPI, and 6.34% in CI. Two knees showed patella infera according to ISI, one according to BPI and three according to CI. There were no significant correlations between the indexes and clinical status of the patients. Elevation of patella relative to the femur in closing wedge valgus HTO procedure due to the shortening of the segment between tibial tuberosity and joint line is normally expected. A significant decrease in patellar height according to ISI suggests that there should be patellar tendon shortening as patellar height cannot be changed. BPI and CI for determining patellar height in valgus HTO do not accurately measure the alteration of patella because they may affect the tibial inclination and antero-posterior translation of the proximal fragment. Another measuring system based on femoral reference points should be proposed to determine the exact change of patellar height in the valgus HTO procedure

    Development and Mechanical Modeling of Si1-xGex/Si MQW Based Uncooled Microbolometers in a 130 nm BiCMOS

    No full text
    This paper presents the development of process integration and mechanical modeling of a Si1-xGex/Si MQW based uncooled micro-bolometer. The recent progress on layer transfer based integration scheme of Si1-xGex/Si based micro-bolometer into a 130 nm BiCMOS process is presented. The two important parts of the process integration, namely the layer-transfer and stress compensation of the arms are studied. The initial successful results on layer transfer and the FEM modeling for the stress compensation of the thin and narrow arms of the bolometer is presented. Finally, the developed FEM model is compared with the fabricated cantilevers. The results show that the developed FEM model has a very good matching with the experimental results; thus very convenient to use for the FEM modeling of the full bolometer structure
    corecore