16 research outputs found

    Assessment of adipokines, adenine nucleotides and uric acid in the dynamics of coronary intervention

    Get PDF
    Introduction: The association of vaspin and visfatin, with a myocardial infarction is still not fully understood. Reduced levels of adenine nucleotides are hallmarks of chronic heart failure. There is little data concerning the relationship between these markers and their changes over time. Material/Methods: The concentration of adenine nucleotides, vaspin and visfatinwere assessed in 41 consecutive patients with acute myocardial infarction one before (day I) and four days after (day IV) percutaneous coronary intervention (PCI) and a control group. Results: Visfatin concentrations were higher before and after PCI vs. control (visfatin I: median 25.55, 20.12 - 30.69 ng/ml; visfatin IV: median 20.79, 16.89 - 25.61 ng/ml vs. control: median 14.94, 10.66 - 25.25 ng/ml; p < 0.0001). Vaspin concentrations were lower before and after PCI vs. control (vaspin I: median 0.18, 0.11 - 0.44 ng/ml; vaspin IV: median 0.24, 0.15 - 0.58 ng/ml vs. control: median 1.303, 1.13 - 2.26 ng/ml, p < 0.00001). Concentrations of visfatin, day I, correlated well to vaspin concentrations (r2 = 0.201, p = 0.011). ATP levels were significantly lower in patients vs. controls (day I: p = 0.00012; day IV: p = 0.0001). Conclusions: Changes in the analyzed visfatin and vaspin concentrations can be used as potential MI markers. Visfatin serum concentration may be considered a potential marker to differentiate MI over time

    Application of atomic absorption spectrometry in trace analsyes of clinical samples (blood)

    No full text
    Spektrometria absorpcji atomowej (AAS) jest instrumentalną metodą analityczną pozwalającą na oznaczanie śladowych ilości pierwiastków w próbkach o różnym charakterze, także klinicznych. Metoda ta należy do optycznych metod spektroskopowych i bada oddziaływanie promieniowania z zakresu UV i VIS na atomy. W metodzie tej wykorzystywane jest zjawisko absorpcji atomowej. W pracy zbadano i opisano korelacje między ilością pierwiastków w surowicy krwi i krwinkach czerwonych. Zawartość pierwiastków oznaczono stosując płomieniową i bezpłomieniową spektrometrię absorpcji atomowej. Analizę korelacji wykonano w odniesieniu do takich pierwiastków, jak wapń (Ca), magnez (Mg), cynk (Zn), miedź (Cu), żelazo (Fe), glin (Al), ołów (Pb), kadm (Cd) i chrom (Cr).Atomic absorption spectrometry (AAS) is an instrumental analytical method dedicated for the determination of trace amounts of elements in samples of different nature, including clinical trials. It belongs to the optical spectroscopic methods and examines the impact of UV and VIS radiation on atoms. This method utilizes an atomic absorption phenomenon. In the study, correlations between the number of elements in the blood serum and red blood cells are described. The content of elements was determined using the flame and flameless atomic absorption spectrometry. The correlation analysis was performed with respect to such elements as calcium (Ca), magnesium (Mg), zinc (Zn), copper (Cu), iron (Fe), aluminium (Al), lead (Pb), cadmium (Cd), and chromium (Cr)

    Application of atomic absorption spectrometry in environmental monitoring based on the comparative analysis of element contents in red fox tissues

    No full text
    Podejmowane są działania pozwalające w sposób nieinwazyjny monitorować środowisko z wykorzystaniem organizmów żywych. Celem prezentowanej pracy była porównawcza ocena zawartości pierwiastków w tkance mięśniowej i sierści lisa rudego oraz analiza korelacji między nimi. Skład pierwiastkowy tkanek badany był z zastosowaniem spektrometrii absorpcji atomowej AAS. Średnie stężenie pierwiastków w tkance mięsnej/sierści było następujące (žg/g): Ca - 81/758, Mg - 225/87, Zn - 23.7/129, Cu - 1.54/6, Fe - 36.6/31, Mn - 0.19/4.4, Pb - 0.12/0.3, Cd - 0.005/0.02, Al - 0.83/1.45, Cr - 0.34/0.42, Ni - 0.14/0.33. Stwierdzono, iż wiek i masa ciała wpływają na poziom Mn, Al i Fe. Statystycznie istotna korelacja między ilością Mn w tkance mięśniowej i w sierści może świadczyć o tym, iż sierść lisa może być dobrym wskaźnikiem zawartości tego pierwiastka w jego organizmie.Works are being undertaken to monitor the environ-ment with the use of living organisms in non-invasively way. The aim of this study was a comparative evaluation of elements content in muscle tissue and hair of red fox and the analysis of correlation between them. Elemental composition of tissues has been tested using atomic absorption spectrometry (AAS) method. The average concentrations of elements in the meat tissue/hair were as follows: Ca - 81/758, Mg - 225/87, Zn - 23.7/129, Cu - 1.54/6, Fe - 36.6/31, Mn - 0.19/4.4, Pb - 0.12/0.3, Cd - 0.005/0.02, Al - 0.83/1.45, Cr - 0.34/0.42 and Ni - 0.14/0.33 (žg/g). It was found that age and body weight influence on the level of Mn, Al, and Fe. A statistically significant correlation between the Mn amount in the muscle and hair may indicate that red fox hair can be a good indicator of the content of this element in his body

    Calibration of military optoelectronic equipment at the Central Military Calibration Laboratory

    No full text
    Przedstawiony poniżej artykuł opisuje stanowiska pomiarowe do odtwarzania i przekazywania jednostek wielkości optoelektronicznych. Autorzy opisali trzy główne działy wielkości optoelektronicznych, których kontrola metrologiczna możliwa jest w Centralnym Wojskowym Ośrodku Metrologii w Warszawie.This paper presents measuring installation to reproduce and transfer optoelectronics values. Authors present three major optoelectronics sections which calibrations are possible at the Central Military Calibration Laboratory in Warsaw

    Zastosowanie spektrometrii absorpcji atomowej w badaniach zawartości pierwiastków i metali ciężkich w próbkach biologicznych - włosach ludzkich

    No full text
    Hair analysis is used in assessment of the body mineral status, and environmental or occupational exposures. This study was undertaken to compare the elements concentrations [calcium (Ca), magnesium (Mg), zinc (Zn), copper (Cu), iron (Fe), lead (Pb), and cadmium (Cd)] in hair from 995 persons taken in the years 2007-2010. The measurements were performed by atomic absorption spectrometry (AAS). The average values for concentrations were as follows (in ?g/g): Ca - 414, Mg - 19, Zn - 160, Cu - 13, Fe - 10, Pb - 1.0, Cd - 0.07. The contents of Ca, Mg, Zn, Cu were statistically higher in the hair of females in comparison with males and the concentrations of Pb and Cd were lower. Significant correlations were found to exist between age of volunteers and the amounts of Ca, Mg, Zn, Fe and Pb. Both in case of correlations between age and elements contents and the correlating metals pairs, the variations between females and males hair were stated.Włosy, krew i mocz są wykorzystywane w ocenie stanu pierwiastkowego organizmu oraz środowiskowej i zawodowej na nie ekspozycji. Niniejsza praca została podjęta w celu określenia zawartości pierwiastków i metali ciężkich we włosach kobiet i mężczyzn (995 osób). Włosy pobierano w latach 2007-2010. Oznaczono zawartość takich pierwiastków, jak: Ca, Mg, Zn, Cu, Fe, Pb i Cd. Średnie stężenie pierwiastków (?g/g) w badanych próbkach włosów było następujące: Ca - 414, Mg - 19, Zn - 160, Cu - 13, Fe - 10, Pb - 1.0, Cd - 0.07. W badaniach zastosowano metodę spektrometrii absorpcji atomowej. Stwierdzono istotne różnice w zawartości pierwiastków we włosach kobiet i mężczyzn, a także znamienne korelacje między zawartością pierwiastków i wiekiem badanych osób

    Measurement system to control parameters of thermovision cameras that are used by Polish army

    No full text
    Na wyposażeniu Wojska Polskiego znajduje się duża ilość różnych typów kamer termowizyjnych. Są one głównie częścią składową systemów obserwacyjnych i kierowania ogniem. Każdy sprzęt wojskowy podlega okresowym przeglądom i remontom. Przy każdej takiej operacji należy sprawdzać parametry urządzeń obserwacyjnych. Należy także pamiętać, że w trakcie użytkowania parametry urządzeń obserwacyjnych ulegają pogorszeniu. Obecnie na wyposażeniu WP nie znajduje się stanowisko pomiarowe mogące zweryfikować podstawowe parametry kamer termowizyjnych. Prezentowane stanowisko pomiarowe ma za zadanie pomiar wszystkich parametrów kamer termowizyjnych mających wpływ na jakość generowanego obrazu.Many thermal camera of different types are used by the Polish Armed Forces. These cameras are parts of observation and fire control systems. As any other kind of military equipment, the cameras must undergo service and maintenance procedures. At that time, their basic parameters have to be checked, as they usually deteriorate with time. The presented test stand is designed to measure all the parameters of thermal cameras that influence the quality of an output image

    Assessment of adipokines, adenine nucleotides and uric acid in the dynamics of coronary intervention

    No full text
    Introduction: The association of vaspin and visfatin, with a myocardial infarction is still not fully understood. Reduced levels of adenine nucleotides are hallmarks of chronic heart failure. There is little data concerning the relationship between these markers and their changes over time. Material/Methods: The concentration of adenine nucleotides, vaspin and visfatinwere assessed in 41 consecutive patients with acute myocardial infarction one before (day I) and four days after (day IV) percutaneous coronary intervention (PCI) and a control group. Results: Visfatin concentrations were higher before and after PCI vs. control (visfatin I: median 25.55, 20.12 - 30.69 ng/ml; visfatin IV: median 20.79, 16.89 - 25.61 ng/ml vs. control: median 14.94, 10.66 - 25.25 ng/ml; p < 0.0001). Vaspin concentrations were lower before and after PCI vs. control (vaspin I: median 0.18, 0.11 - 0.44 ng/ml; vaspin IV: median 0.24, 0.15 - 0.58 ng/ml vs. control: median 1.303, 1.13 - 2.26 ng/ml, p < 0.00001). Concentrations of visfatin, day I, correlated well to vaspin concentrations (r2 = 0.201, p = 0.011). ATP levels were significantly lower in patients vs. controls (day I: p = 0.00012; day IV: p = 0.0001). Conclusions: Changes in the analyzed visfatin and vaspin concentrations can be used as potential MI markers. Visfatin serum concentration may be considered a potential marker to differentiate MI over time
    corecore