265 research outputs found
Bilateral Facial Paralysis Caused by Temporal Bone Fracture: A Case Report
Introduction: Although bilateral facial nerve palsy is a rare condition, its etiology is more detectable than the unilateral type. A temporal bone fracture is one cause of bilateral facial nerve palsy, contributing in 3% of the cases.
Case Presentation: Here, we report the case of a 35-year-old man complaining of bilateral incomplete eye closure, two weeks after a closed head injury caused by a motor vehicle accident.
Conclusions: The high resolution computed tomography findings revealed a bilateral temporal bone fracture line, which extended to the fallopian canal. With regard to treatment, near complete recovery was obvious after two weeks of treatment with oral corticosteroids. Overall, bilateral facial palsy is hard to diagnose; therefore, clinical suspicion and the early detection of facial nerve injuries is necessary for good nerve recovery in temporal bone fractures
Postpartum Sexual Function; Conflict in Marriage Stability: A Systematic Review
Background: One of the most important issues affecting the stability of marriage is sexual function, so its problem can lead to divorce or separation of the couple. Pregnancy and delivery as one the most important periods of women's life can have significant effects on sexual function. This study reviews the postpartum sexual function and its related factors in Iran.Methods: This study is a systematic review of the sexual function after childbirth in Iran. By using of valid keywords and searching in databases such as Google scholar, SID, Magiran, Medlib, Irandoc, Iranmedex, the total number of 15 articles between 2005 and 2012 years have been evaluated. Results were reported quantitatively and qualitatively.Results: Total Sample was 4109 women, with an average of 274 samples per study. Plenty of studies in Tehran was 46% and other cities was 54%. The majority of studies showed no relation between mode of delivery and sexual function (P=0.14), but there were significant relation between lactation and postpartum sexual function (P<0.05) as, breastfeeding decreased sexual function. Also sexual function score has decreased with increasing parity.Conclusion: According to the effects of lactation and parity on women sexual function, therefore high risk for divorce, sex education after childbirth, especially in the first six months after delivery, maybe helpful in prevention of sexual dysfunction after delivery
Walking through architectural spaces: The impact of interior forms on human brain dynamics
Ā© 2017 Banaei, Hatami, Yazdanfar and Gramann. Neuroarchitecture uses neuroscientific tools to better understand architectural design and its impact on human perception and subjective experience. The form or shape of the built environment is fundamental to architectural design, but not many studies have shown the impact of different forms on the inhabitantsā emotions. This study investigated the neurophysiological correlates of different interior forms on the perceiversā affective state and the accompanying brain activity. To understand the impact of naturalistic three-dimensional (3D) architectural forms, it is essential to perceive forms from different perspectives. We computed clusters of form features extracted from pictures of residential interiors and constructed exemplary 3D room models based on and representing different formal clusters. To investigate human brain activity during 3D perception of architectural spaces, we used a mobile brain/body imaging (MoBI) approach recording the electroencephalogram (EEG) of participants while they naturally walk through different interior forms in virtual reality (VR). The results revealed a strong impact of curvature geometries on activity in the anterior cingulate cortex (ACC). Theta band activity in ACC correlated with specific feature types (rs (14) = 0.525, Ļ = 0.037) and geometry (rs (14) = ā0.579, Ļ = 0.019), providing evidence for a role of this structure in processing architectural features beyond their emotional impact. The posterior cingulate cortex and the occipital lobe were involved in the perception of different room perspectives during the stroll through the rooms. This study sheds new light on the use of mobile EEG and VR in architectural studies and provides the opportunity to study human brain dynamics in participants that actively explore and realistically experience architectural spaces
Two Inputs Five-Level Quasi-Z-Source Inverter
This paper combines quasi-Z-source into a typical five-level inverter, which includes two dc voltage sources, two quasi-Z-sources and five switching devices. In this structure, the output voltage amplitude is not limited to dc voltage source and it can be increased by quasi-Z-source. Besides, due to nature of Z-source families, this new structure is reliable and higher efficiency. Also, in this inverter, two quasi-Z-networks can be controlled independently. This paper also proposes new switching algorithms for proposed five-level dual quasi-Z-Source inverter based on pulse width modulation (PWM) and selective harmonic elimination method (SHEM) algorithms .The performance of proposed inverter and switching algorithm are validated with simulation results using MATLAB/SIMULINK software and experimental results based PCI-1716 data acquisition system
Analysis of Switched Inductor Three-level DC/DC Converter
A non-isolated DC/DC converter with high transfer gain is proposed in this paper. The presented converter consists of the switched inductor and three-level converters. The DC/DC power converter is three-level boost converter to convert the output voltage of the DC source into two voltage sources. The main advantages of DC/DC converter are using low voltage semiconductors and high gain voltage. The steady-state operation of the suggested converter is analyzed. A prototype is developed and tested to verify the performance of the proposed converter. To sum up, the MATLAB simulation results and the experimental results have transparently approved high efficiency of proposed converter as well as its feasibility
An Isolated Off-Line High Power Factor Electrolytic Capacitor-Less LED Driver with Pulsating Output Current
One of the most efficient lighting technology is based on light-emitting diodes (LEDs). Common LED drivers with AC-input (50-60Hz) usually require a bulk electrolytic capacitor to decrease low-frequency ripple in the output. However, the critical element that limits the lifespan of the LED driver is the electrolytic capacitor. An isolated off-line LED driver is proposed in this paper, in which the required output capacitance is reduced so that the electrolytic capacitor can be omitted from the driver structure. The driverās configuration and controlling method provide a high input power factor. Just a single switch and therefore a single controlling IC have been used in the proposed structure. The input power factor correction is implemented utilizing a boost-based method, and a novel structure is introduced for dc/dc conversion section. Power factor correction and dc/dc conversion are performed employing a simplistic and single controlling system. The output current feeding the LEDs is a high frequency pulsating current. Calculations, simulations and experimental waveforms of a laboratory prototype are presented to confirm the validity of the proposed driver
Two-Stage Inverter Based on Combination of High Gain DC-DC Converter and Five-Level Inverter for PV-Battery Energy Conversion
This paper proposes a new two-stage inverter based on transformer-less high gain DC-DC converter for energy conversion of a photovoltaic system. The designed system consists of a high gain DC-DC converter cascaded with a three-phase inverter. The proposed DC-DC converter has a simple structure, and it has one switch in its structure. The output voltage of the DC-DC converter supplies DC source for the inverter part of the multi-stage inverter. The advanced two-stage inverter sample was fabricated, then the findings of the acquired simulation and hardware warranted the configuration applicability. Finally, the MATLAB/SIMULINK is employed for the simulation of PV-battery system. The obtained results revel that the proposed power conversion system effectively chases the load and generation fluctuations and also properly handles the power mismatches in PV-battery system
Dosimetric Comparison of Four Different Techniques for Supraclavicular Irradiation in 3D-conformal Radiotherapy of Breast Cancer
This study aimed to compare and evaluated the dosimetric characteristics of esophagus, spinal cord, carotid artery, lungs, and brachial plexus in patients with breast cancer undergoing four various techniques of supraclavicular irradiation. By keeping unchanged the breast tangential radiotherapy fields, four different treatment field arrangements were created to irradiate the supraclavicular region as follows: (1) four field (4F; 1 anterior-posterior and 1 posterior-anterior), (2) six field (6F; 2 anterior-posterior and 2 posterior-anterior), (3) five field-1 (5F-1; 2 anterior-posterior and 1 posterior-anterior), and (4) five field-2 (5F-2; 1 anterior-posterior and 2 posterior-anterior). Then, the dosimetric parameters for the above-mentioned organs were evaluated. The mean dose (Dmean) of the esophagus had significant difference between 6F and 5F-2 techniques. For the spinal cord, the Dmean dosimetric parameter demonstrated significant difference between the 4F and 6F techniques, and between the 4F and 5F-1 techniques, with lower values for the 4F technique. There was no significant difference between the different irradiation techniques in all the dosimetric parameters for the carotid artery. The Dmean of the left lung significantly differed between the 4F and 5F-2 techniques, with lower values for the 5F-2 technique. Furthermore, the V20Gy dosimetric parameter had significant difference between the 4F and 6F, and also 4F and 5F-2, techniques with lower values for 5F-2. The maximum dose (Dmax) of the brachial plexus showed significant difference between the two techniques of 5F. The V45Gy dosimetric parameter of the brachial plexus revealed significant difference between the 4F and 6F techniques, and also between the 4F and 5F-1 techniques, with lower values for 5F-1. In general, these techniques had similar dosimetric results, with little differences. The dosimetric parameters for the esophagus and lung showed better results with the 5F-2 technique in comparison with other techniques. Dosimetric results for the brachial plexus and spinal cord improved with the 5F-1 and 4F techniques, respectively, against other techniques. Dose distribution for the carotid artery did not differ in the four irradiation techniques
Applications of electroencephalography in construction
A wearable electroencephalogram (EEG) is considered a means for investigating psychophysiological conditions of individuals in the workplace in order to ameliorate occupational health and safety. Following other sectors, construction scholars have adopted this technology over the past decade to strengthen evidence-based practices to improve the wellbeing of workers. This study presents the state-of-the-art hardware, algorithms, and applications of EEG as a platform that assists in dealing with the risk-prone and complex nature of construction tasks. After summarizing the background of EEG and its research paradigms in different sectors, a comprehensive review of EEG-enabled construction research is provided. First, through a macro-scale review aided by bibliometric analysis a big picture of the research streams is plotted. Second, a micro-scale review is conducted to spot the gaps in the literature. The identified gaps are used to classify the future research directions into theoretical, application, and methodological developments
- ā¦