165 research outputs found

    Building irregularity issues and architectural design in seismic areas

    Get PDF

    Design of Distributed Spiral Resonators for the Decoupling of MRI Double-Tuned RF Coils

    Get PDF
    © 1964-2012 IEEE. Objective: A systematic analytical approach to design Spiral Resonators (SRs), acting as distributed magnetic traps (DMTs), for the decoupling of concentric Double-Tuned (DT) RF coils suitable for Ultra-High Field (7 T) MRI is presented. Methods: The design is based on small planar SRs placed in between the two RF loops (used for signal detection of the two nuclei of interest). We developed a general framework based on a fully analytical approach to estimate the mutual coupling between the RF coils and to provide design guidelines for the geometry and number of SRs to be employed. Starting from the full-analytical estimations of the SRs geometry, electromagnetic simulations for improving and validating the performance can be carried out. Results and Conclusion: We applied the method to a test case of a DT RF coil consisting of two concentric and coplanar loops used for 7 T MRI, tuned at the Larmor frequencies of the proton (1H, 298 MHz) and sodium (23Na, 79 MHz) nuclei, respectively. We performed numerical simulations and experimental measurements on fabricated prototypes, which both demonstrated the effectiveness of the proposed design procedure. Significance: The decoupling is achieved by printing the SRs on the same dielectric substrate of the RF coils thus allowing a drastic simplification of the fabrication procedure. It is worth noting that there are no physical connections between the decoupling SRs and the 1H/23Na RF coils, thus providing a mechanically robust experimental set-up, and improving the transceiver design with respect to other traditional decoupling techniques

    Double-Tuned Birdcage Radio Frequency Coil for 7 T MRI: Optimization, Construction and Workbench Validation

    Get PDF
    The aim of the present study is the optimization, construction, and workbench validation of a double-tuned 1H- 23Na volume radio frequency (RF) coil suitable for human head imaging at 7 T, based on the birdcage geometry. The birdcage-like design which is considered is the four-ring model, in which two standard birdcage-like structures with the same diameters are nested along the longitudinal axis. Simulations based on Maxwell’s equations are performed to evaluate the RF magnetic field homogeneity and the RF coil efficiency varying the coil geometrical parameters. The RF magnetic field homogeneity is evaluated both on the transverse (z = 0) and longitudinal (y = 0) planes without performing the impedance matching procedure, so that the RF coil symmetry is not perturbed by the matching network. The RF coil efficiency is instead dependent on the effective coil input RF power, and it is evaluated after matching the coil, so that the reflected power is minimized, assuming that the stimulation power is totally delivered to the RF coil. Considering the simulation results and the target application, the useful RF coil geometrical parameters are fixed. The four-ring model, which showed the best performances, has been built and tested on a workbench, using a cylindrical phantom filled with a 0.05 M saline solution as load. This provides the first example of a four-ring realization intended 1H- 23Na for human head imaging at 7 T

    Design of Distributed Spiral Resonators for the Decoupling of MRI Double-Tuned RF Coils

    Get PDF
    OBJECTIVE: A systematic analytical approach to design Spiral Resonators (SRs), acting as distributed magnetic traps (DMTs), for the decoupling of concentric Double-Tuned (DT) RF coils suitable for Ultra-High Field (7 T) MRI is presented. METHODS: The design is based on small planar SRs placed in between the two RF loops (used for signal detection of the two nuclei of interest). We developed a general framework based on a fully analytical approach to estimate the mutual coupling between the RF coils and to provide design guidelines for the geometry and number of SRs to be employed. Starting from the full-analytical estimations of the SRs geometry, electromagnetic simulations for improving and validating the performance can be carried out. RESULTS AND CONCLUSION: We applied the method to a test case of a DT RF coil consisting of two concentric and coplanar loops used for 7 T MRI, tuned at the Larmor frequencies of the proton (1H, 298 MHz) and sodium (23Na, 79 MHz) nuclei, respectively. We performed numerical simulations and experimental measurements on fabricated prototypes, which both demonstrated the effectiveness of the proposed design procedure. SIGNIFICANCE: The decoupling is achieved by printing the SRs on the same dielectric substrate of the RF coils thus allowing a drastic simplification of the fabrication procedure. It is worth noting that there are no physical connections between the decoupling SRs and the 1H/23Na RF coils, thus providing a mechanically robust experimental set-up, and improving the transceiver design with respect to other traditional decoupling techniques

    INNOVATIVE AND ECO-COMPATIBLE MATERIALS FOR THE REGENERATION OF THE HISTORICAL BUILDINGS LOCATED IN THE MED AREA

    Get PDF

    Validation of numerical approaches for electromagnetic characterization of magnetic resonance radiofrequency coils

    Get PDF
    Numerical methods based on solutions of Maxwell's equations are usually adopted for the electromagnetic characterization of Magnetic Resonance (MR) Radiofrequency (RF) coils. In this context, many different numerical methods can be employed, including time domain methods, e.g., the Finite-Difference Time-Domain (FDTD), and frequency domain methods, e.g., the Finite Element Methods (FEM) and the Method of Moments (MoM). We provide a quantitative comparison of performances and a detailed evaluation of advantages and limitations of the aforementioned methods in the context of RF coil design for MR applications. Specifically, we analyzed three RF coils which are representative of current geometries for clinical applications: a 1.5 T proton surface coil; a 7T dual tuned surface coil; a 7T proton volume coil. The numerical simulation results have been compared with measurements, with excellent agreement in almost every case. However, the three methods differ in terms of required computing resources (memory and simulation time) as well as their ability to handle a realistic phantom model. For this reason, this work could provide "a guide to select the most suitable method for each specific research and clinical applications at low and high field"

    Promoter Methylation Leads to Decreased ZFP36 Expression and Deregulated NLRP3 Inflammasome Activation in Psoriatic Fibroblasts

    Get PDF
    The mRNA-destabilizing protein tristetraprolin (TTP), encoded by the ZFP36 gene, is known to be able to end inflammatory responses by directly targeting and destabilizing mRNAs encoding pro-inflammatory cytokines. We analyzed its role in psoriasis, a disease characterized by chronic inflammation. We observed that TTP is downregulated in fibroblasts deriving from psoriasis patients compared to those deriving from healthy individuals and that psoriatic fibroblasts exhibit abnormal inflammasome activity compared to their physiological counterpart. This phenomenon depends on TTP downregulation. In fact, following restoration, TTP is capable of directly targeting for degradation NLRP3 mRNA, thereby drastically decreasing inflammasome activation. Moreover, we provide evidence that ZFP36 undergoes methylation in psoriasis, by virtue of the presence of long stretches of CpG dinucleotides both in the promoter and the coding region. Besides confirming that a perturbation of TTP expression might underlie the pathogenesis of psoriasis, we suggest that deregulated inflammasome activity might play a role in the disease alongside deregulated cytokine expression
    • …
    corecore