463 research outputs found
Generalized Romberg methods for integrals of derivatives
Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/46316/1/211_2005_Article_BF02165095.pd
Paper and electronic versions of HM-PRO, a novel patient-reported outcome measure for hematology: an equivalence study.
© 2019 Goswami, Oliva, Ionova et al.Aim:To determine measurement equivalence of paper and electronic application of the hematologi-cal malignancy-patient-reported outcome (HM-PRO), a specific measure for the evaluation of patient-reported outcomes in HMs.Patients & methods:Following International Society of Pharmacoeconomicsand Outcomes Research ePRO Good Research Practice Task Force guidelines, a total of 193 adult patientswith different HMs were recruited into a multicenter prospective study. The paper and the electronic ver-sion of the instrument were completed in the outpatient clinics in a randomized crossover design with a30-min time interval to minimize the learning effect. Those who completed the paper version first, com-pleted the electronic version after 30 min and vice versa. Instrument version and order effects were testedon total score of the two parts of the HM-PRO (Part A: quality of life and Part B: signs & symptoms) in atwo-way ANOVA with patients as random effects. Intraclass correlation coefficients (95% CI) and Spear-man’s rank correlation coefficients were used to evaluate test–retest reliability and reproducibility. Theeffects of instrument version and order were tested on total score of the two parts of HM-PRO.Results:The questionnaire version and administration order effects were not significant at the 5% level. Therewere no interactions found between these two factors for HM-PRO (Part A [quality of life]; p=0.95); and(part B [signs and symptoms]; p=0.72]. Spearman’s rank correlation coefficients were greater than 0.9, andintraclass correlation coefficients ranged from 0.94 to 0.98; furthermore, the scores were not statisticallydifferent between the two versions, showing acceptable reliability indexes. Noteworthy, the differencebetween the completion time for both paper (mean=6:38 min) and electronic version (mean=7:29 min)was not statistically significant (n=100; p=0.11). Patients did not report any difficulty in completing theelectronic version during cognitive interviews and were able to understand and respond spontaneously.Conclusion:Measurement equivalence has been demonstrated for the paper and electronic applicationof the HM-PRO.Peer reviewe
Exact diagonalization of the S=1/2 Heisenberg antiferromagnet on finite bcc lattices to estimate properties on the infinite lattice
Here we generate finite bipartite body-centred cubic lattices up to 32
vertices. We have studied the spin one half Heisenberg antiferromagnet by
diagonalizing its Hamiltonian on each of the finite lattices and hence
computing its ground state properties. By extrapolation of these data we obtain
estimates of the T = 0 properties on the infinite bcc lattice. Our estimate of
the T = 0 energy agrees to five parts in ten thousand with third order spin
wave and series expansion method estimates, while our estimate of the staggered
magnetization agrees with the spin wave estimate to within a quarter of one
percent.Comment: 16 pages, LaTeX, 1 ps figure, to appear in J.Phys.
Aspirin for the older person: report of a meeting at the Royal Society of Medicine, London, 3rd November 2011
On November 23rd 2011, the Aspirin Foundation held a meeting at the Royal Society of Medicine in London to review current thinking on the potential role of aspirin in preventing cardiovascular disease and reducing the risk of cancer in older people. The meeting was supported by Bayer Pharma AG and Novacyl
Calibration of the Quadrupole Mass Spectrometer of the Sample Analysis at Mars Instrument Suite
The SAM suite of instruments on the "Curiosity" Rover of the Mars Science Laboratory (MSL) is designed to provide chemical and isotopic analysis of organic and inorganic volatiles for both atmospheric and solid samples. The mission of the MSL investigations is to advance beyond the successful search for aqueous transformation in surface environments at Mars toward a quantitative assessment of habitability and preservation through a series of chemical and geological measurements. The SAM suite was delivered in December 2010 (Figure 1) to the Jet Propulsion Laboratory for integration into the Curiosity Rover. We previously outlined the range of SAM solid and gas calibrations implemented or planned and here we discuss a specific set of calibration experiments to establish the response of the SAM Quadrupole Mass Spectrometer (QMS) to the four most abundant gases in the Martian atmosphere CO2, N2, Ar, and O2, A full SAM instrument description and calibration report is presently in preparation
Circulating endocannabinoids during hematopoietic stem cell transplantation: A pilot study
AbstractObjectiveHematopoietic stem cell transplantation (HCT) is a stressful and rigorous medical procedure involving significant emotional and immune challenges. The endocannabinoid (eCB) signaling system is involved in regulation of both the immune system and emotional reactivity, yet little is known about its function during HCT. We investigated the role of the eCB signaling system in a group of HCT recipients.MethodsA total of 19 HCT recipients were enrolled and provided psychosocial data and blood samples at three peri-transplant time points: prior to transplant, hospital discharge, and approximately 100 days post-transplant. Psychosocial factors, inflammatory molecules, and the eCBs were determined and assessed for changes over this period and association with each other.ResultsHCT recipients demonstrated significant changes over the peri-transplant period in inflammatory molecules and psychosocial functioning, but not in circulating concentrations of the eCBs. Associations among these variables were most likely to be present pre-transplant and least likely to be present immediately post-transplant, with depressive symptoms and inflammation most significantly associated. The eCB 2-arachidonoylglycerol (2-AG) was significantly, positively associated with both interleukin (IL)-6 and C-reactive protein (CRP) and negatively associated with depressive symptoms.ConclusionsThe eCB signaling system may have alternative sources and regulatory mechanisms in addition to the immune system. Given the significant associations with inflammatory molecules and depressive symptoms in the peri-transplant period, it is important to better understand this system and its potential implications in the setting of complex and stressful medical procedures such as HCT
Improving Empathy in Healthcare Consultations-a Secondary Analysis of Interventions.
A recent systematic review of randomised trials suggested that empathic communication improves patient health outcomes. However, the methods for training healthcare practitioners (medical professionals; HCPs) in empathy and the empathic behaviours demonstrated within the trials were heterogeneous, making the evidence difficult to implement in routine clinical practice. In this secondary analysis of seven trials in the review, we aimed to identify (1) the methods used to train HCPs, (2) the empathy behaviours they were trained to perform and (3) behaviour change techniques (BCTs) used to encourage the adoption of those behaviours. This detailed understanding of interventions is necessary to inform implementation in clinical practice. We conducted a content analysis of intervention descriptions, using an inductive approach to identify training methods and empathy behaviours and a deductive approach to describe the BCTs used. The most commonly used methods to train HCPs to enhance empathy were face-to-face training (n = 5), role-playing (n = 3) and videos (self or model; n = 3). Duration of training was varied, with both long and short training having high effect sizes. The most frequently targeted empathy behaviours were providing explanations of treatment (n = 5), providing non-specific empathic responses (e.g. expressing understanding) and displaying a friendly manner and using non-verbal behaviours (e.g. nodding, leaning forward, n = 4). The BCT most used to encourage HCPs to adopt empathy behaviours was "Instruction on how to perform behaviour" (e.g. a video demonstration, n = 5), followed by "Credible source" (e.g. delivered by a psychologist, n = 4) and "Behavioural practice" (n = 3 e.g. role-playing). We compared the effect sizes of studies but could not extrapolate meaningful conclusions due to high levels of variation in training methods, empathy skills and BCTs. Moreover, the methods used to train HCPs were often poorly described which limits study replication and clinical implementation. This analysis of empathy training can inform future research, intervention reporting standards and clinical practice
In-situ fluorescence spectroscopy is a more rapid and resilient indicator of faecal contamination risk in drinking water than faecal indicator organisms
Faecal indicator organisms (FIOs) are limited in their ability to protect public health from the microbial contamination of drinking water because of their transience and time required to deliver a result. We evaluated alternative rapid, and potentially more resilient, approaches against a benchmark FIO of thermotolerant coliforms (TTCs) to characterise faecal contamination over 14 months at 40 groundwater sources in a Ugandan town. Rapid approaches included: in-situ tryptophan-like fluorescence (TLF), humic-like fluorescence (HLF), turbidity; sanitary inspections; and total bacterial cells by flow cytometry. TTCs varied widely in six sampling visits: a third of sources tested both positive and negative, 50% of sources had a range of at least 720 cfu/100 mL, and a two-day heavy rainfall event increased median TTCs five-fold. Using source medians, TLF was the best predictor in logistic regression models of TTCs ≥10 cfu/100 mL (AUC 0.88) and best correlated to TTC enumeration (ρs 0.81), with HLF performing similarly. Relationships between TLF or HLF and TTCs were stronger in the wet season than the dry season, when TLF and HLF were instead more associated with total bacterial cells. Source rank-order between sampling rounds was considerably more consistent, according to cross-correlations, using TLF or HLF (min ρs 0.81) than TTCs (min ρs 0.34). Furthermore, dry season TLF and HLF cross-correlated more strongly (ρs 0.68) than dry season TTCs (ρs 0.50) with wet season TTCs, when TTCs were elevated. In-situ TLF or HLF are more rapid and resilient indicators of faecal contamination risk than TTCs
Evaluation of Pulse Counting for the Mars Organic Mass Analyzer (MOMA) Ion Trap Detection Scheme
The Mars Organic Mass Analyzer is being developed at Goddard Space Flight Center to identify organics and possible biological compounds on Mars. In the process of characterizing mass spectrometer size, weight, and power consumption, the use of pulse counting was considered for ion detection. Pulse counting has advantages over analog-mode amplification of the electron multiplier signal. Some advantages are reduced size of electronic components, low power consumption, ability to remotely characterize detector performance, and avoidance of analog circuit noise. The use of pulse counting as a detection method with ion trap instruments is relatively rare. However, with the recent development of high performance electrical components, this detection method is quite suitable and can demonstrate significant advantages over analog methods. Methods A prototype quadrupole ion trap mass spectrometer with an internal electron ionization source was used as a test setup to develop and evaluate the pulse-counting method. The anode signal from the electron multiplier was preamplified. The an1plified signal was fed into a fast comparator for pulse-level discrimination. The output of the comparator was fed directly into a Xilinx FPGA development board. Verilog HDL software was written to bin the counts at user-selectable intervals. This system was able to count pulses at rates in the GHz range. The stored ion count nun1ber per bin was transferred to custom ion trap control software. Pulse-counting mass spectra were compared with mass spectra obtained using the standard analog-mode ion detection. Prelin1inary Data Preliminary mass spectra have been obtained for both analog mode and pulse-counting mode under several sets of instrument operating conditions. Comparison of the spectra revealed better peak shapes for pulse-counting mode. Noise levels are as good as, or better than, analog-mode detection noise levels. To artificially force ion pile-up conditions, the ion trap was overfilled and ions were ejected at very high scan rates. Pile-up of ions was not significant for the ion trap under investigation even though the ions are ejected in so-called 'ion-micro packets'. It was found that pulse counting mode had higher dynamic range than analog mode, and that the first amplification stage in analog mode can distort mass peaks. The inherent speed of the pulse counting method also proved to be beneficial to ion trap operation and ion ejection characterization. Very high scan rates were possible with pulse counting since the digital circuitry response time is so much smaller than with the analog method. Careful investigation of the pulse-counting data also allowed observation of the applied resonant ejection frequency during mass analysis. Ejection of ion micro packets could be clearly observed in the binned data. A second oscillation frequency, much lower than the secular frequency, was also observed. Such an effect was earlier attributed to the oscillation of the total plasma cloud in the ion trap. While the components used to implement pulse counting are quite advanced, due to their prevalence in consumer electronics, the cost of this detection system is no more than that of an analog mode system. Total pulse-counting detection system electronics cost is under $25
- …