403 research outputs found

    Effects of dental probing on occlusal surfaces - A scanning electron microscopy evaluation

    Get PDF
    The aim of this clinical-morphological study was to investigate the effects of dental probing on occlusal surfaces by scanning electron microscopy (SEM). Twenty sound occlusal surfaces of third molars and 20 teeth with initial carious lesions of 17- to 26-year-old patients (n = 18) were involved. Ten molars of each group were probed with a sharp dental probe (No. 23) before extraction; the other molars served as negative controls. After extraction of the teeth, the crowns were separated and prepared for the SEM study. Probing-related surface defects, enlargements and break-offs of occlusal pits and fissures were observed on all occlusal surfaces with initial carious lesions and on 2 sound surfaces, respectively. No traumatic defects whatsoever were visible on unprobed occlusal surfaces. This investigation confirms findings of light-microscopic studies that using a sharp dental probe for occlusal caries detection causes enamel defects. Therefore, dental probing should be considered as an inappropriate procedure and should be replaced by a meticulous visual inspection. Critical views of tactile caries detection methods with a sharp dental probe as a diagnostic tool seem to be inevitable in undergraduate and postgraduate dental education programmes. Copyright (c) 2007 S. Karger AG, Basel

    The H3K4me3/2 histone demethylase RBR-2 controls axon guidance by repressing the actin-remodeling gene wsp-1

    Get PDF
    The dynamic regulation of histone modifications is important for modulating transcriptional programs during development. Aberrant H3K4 methylation is associated with neurological disorders, but how the levels and the recognition of this modification affect specific neuronal processes is unclear. Here we show that RBR-2, the sole homolog of the KDM5 family of H3K4me3/me2 demethylases in Caenorhabditis elegans, ensures correct axon guidance by controlling the expression of the actin regulator wsp-1. Loss of rbr-2 results in increased levels of H3K4me3 at the transcriptional start site of wsp-1, with concomitant higher wsp-1 expression responsible for defective axon guidance. In agreement, overexpression of WSP-1 mimics rbr-2 loss, while its depletion restores normal axon guidance in rbr-2 mutants. NURF-1, an H3K4me3-binding protein and member of the chromatin-remodeling complex NURF, is required for promoting aberrant wsp-1 transcription in rbr-2 mutants and its ablation restores wild type expression of wsp-1 and axon guidance. Thus, our results establish a precise role for epigenetic regulation in neuronal development by demonstrating a functional link between RBR-2 activity, H3K4me3 levels, the NURF complex and the expression of WSP-1.</jats:p

    Ultra-high-resolution dual-source CT for forensic dental visualization—discrimination of ceramic and composite fillings

    Get PDF
    Dental identification is the most valuable method to identify human remains in single cases with major postmortem alterations as well as in mass casualties because of its practicability and demanding reliability. Computed tomography (CT) has been investigated as a supportive tool for forensic identification and has proven to be valuable. It can also scan the dentition of a deceased within minutes. In the present study, we investigated currently used restorative materials using ultra-high-resolution dual-source CT and the extended CT scale for the purpose of a color-encoded, in scale, and artifact-free visualization in 3D volume rendering. In 122 human molars, 220 cavities with 2-, 3-, 4- and 5-mm diameter were prepared. With presently used filling materials (different composites, temporary filling materials, ceramic, and liner), these cavities were restored in six teeth for each material and cavity size (exception amalgam n = 1). The teeth were CT scanned and images reconstructed using an extended CT scale. Filling materials were analyzed in terms of resulting Hounsfield units (HU) and filling size representation within the images. Varying restorative materials showed distinctively differing radiopacities allowing for CT-data-based discrimination. Particularly, ceramic and composite fillings could be differentiated. The HU values were used to generate an updated volume-rendering preset for postmortem extended CT scale data of the dentition to easily visualize the position of restorations, the shape (in scale), and the material used which is color encoded in 3D. The results provide the scientific background for the application of 3D volume rendering to visualize the human dentition for forensic identification purpose

    Giant Liquid Argon Observatory for Proton Decay, Neutrino Astrophysics and CP-violation in the Lepton Sector (GLACIER)

    Get PDF
    GLACIER (Giant Liquid Argon Charge Imaging ExpeRiment) is a large underground observatory for proton decay search, neutrino astrophysics and CP-violation studies in the lepton sector. Possible underground sites are studied within the FP7 LAGUNA project (Europe) and along the JPARC neutrino beam in collaboration with KEK (Japan). The concept is scalable to very large masses.Comment: 4 pages, 1 figure, Contribution to the Workshop "European Strategy for Future Neutrino Physics", CERN, Oct. 200

    Evaluation of laser fluorescence in monitoring non-cavitated caries lesion progression on smooth surfaces in vitro.

    Get PDF
    The aim of this study was to evaluate the performance of a pen-type laser fluorescence (LF) device (LFpen: DIAGNOdent pen) to detect and monitor the progression of caries-like lesions on smooth surfaces. Fifty-two bovine enamel blocks were submitted to three different demineralisation cycles for caries-like lesion induction using Streptococcus mutans, Lactobacillus casei and Actinomyces naeslundii. At baseline and after each cycle, the enamel blocks were analysed under Knoop surface micro-hardness (SMH) and an LFpen. One enamel block after each cycle was randomly chosen for Raman spectroscopy analysis. Cross-sectional micro-hardness (CSMH) was performed at different depths (20, 40, 60, 80 and 100 μm) in 26 enamel blocks after the second cycle and 26 enamel blocks after the third cycle. Average values of SMH (± standard deviation (SD)) were 319.3 (± 21.5), 80.5 (± 31.9), 39.8 (± 12.7), and 29.77 (± 10.34) at baseline and after the first, second and third cycles, respectively. Statistical significant difference was found among all periods (p  0.05). One sample of each cycle was characterised through Raman spectroscopy analysis. It can be concluded that LF was effective in detecting the first demineralisation on enamel; however, the method did not show any effect in monitoring lesion progression after three cycles of in vitro demineralisation

    Basic Erosive Wear Examination (BEWE): a new scoring system for scientific and clinical needs

    Get PDF
    A new scoring system, the Basic Erosive Wear Examination (BEWE), has been designed to provide a simple tool for use in general practice and to allow comparison to other more discriminative indices. The most severely affected surface in each sextant is recorded with a four level score and the cumulative score classified and matched to risk levels which guide the management of the condition. The BEWE allows re-analysis and integration of results from existing studies and, in time, should initiate a consensus within the scientific community and so avoid continued proliferation of indices. Finally, this process should lead to the development of an internationally accepted, standardised and validated index. The BEWE further aims to increase the awareness of tooth erosion amongst clinicians and general dental practitioners and to provide a guide as to its management

    Fluoride varnishes containing calcium glycerophosphate: fluoride uptake and the effect on in vitro enamel erosion

    Get PDF
    OBJECTIVES Calcium glycerophosphate (CaGP) was added to fluoride varnishes to analyze their preventive effect on initial enamel erosion and fluoride uptake: potassium hydroxide (KOH)-soluble and KOH-insoluble fluoride bound to enamel. MATERIALS AND METHODS This study was carried out in two parts. Part 1: 108 enamel samples were randomly distributed into six varnish groups: base varnish (no active ingredients); Duraphat® (2.26 %NaF); Duofluorid® (5.63 %NaF/CaF2); experimental varnish 1 (1 %CaGP/5.63 %NaF/CaF2); experimental varnish 2 (5 %CaGP/5.63 %NaF/CaF2); and no varnish. Cyclic demineralization (90 s; citric acid, pH = 3.6) and remineralization (4 h) was made once a day, for 3 days. Change in surface microhardness (SMH) was measured. Part 2: 60 enamel samples were cut in half and received no varnish (control) or a layer of varnish: Duraphat®, Duofluorid®, experimental varnishes 1 and 2. Then, KOH-soluble and KOH-insoluble fluoride were analyzed using an electrode. RESULTS After cyclic demineralization, SMH decreased in all samples, but Duraphat® caused less hardness loss. No difference was observed between varnishes containing CaGP and the other varnishes. Similar amounts of KOH-soluble and insoluble fluoride was found in experimental varnish 1 and Duofluorid®, while lower values were found for experimental varnish 2 and Duraphat®. CONCLUSION The addition of CaGP to fluoride varnishes did not increase fluoride bound to enamel and did not enhance their protection against initial enamel erosion. CLINICAL RELEVANCE We observe that the fluoride varnishes containing CaGP do not promote greater amounts of fluoride bound to enamel and that fluoride bound to enamel may not be closely related to erosion prevention

    In vitro evaluation of modified surface microhardness measurement, focus variation 3D microscopy and contact stylus profilometry to assess enamel surface loss after erosive-abrasive challenges

    Get PDF
    The aim of the study was to compare surface loss values after erosion-abrasion cycles obtained with modified surface microhardness measurement (mSMH), focus variation 3D microscopy (FVM) and contact stylus profilometry (CSP). We cut human molars into buccal and lingual halves, embedded them in resin and ground 200 μm of enamel away. The resulting surfaces were polished. To maintain a reference area, we applied Block-Out resin to partly cover the enamel surface. The samples were incubated in artificial saliva (37°C; 1 h), then rinsed in deionized water (10 s) and dried with oil-free air (5 s). We immersed the specimens individually in 30 mL citric acid (1%, pH 3.6) for 2 min (25°C, 70 rpm dynamic conditions) before brushing them (50 strokes, 200 g) in an automatic brushing machine with toothpaste-slurry. We calculated the surface loss as per mSMH, by re-measuring the length of the same six indentations made before the abrasive challenge. The experiment consisted of five experimental groups that received between 2 and 10 erosion-abrasion cycles. Each group contained 15 specimens and samples in groups 1, 2, 3, 4 and 5 underwent a total of 2, 4, 6, 8 and 10 cycles, respectively. The resin was removed from the reference area in one piece under 10× magnification and the FVM and CSP were performed. Agreement between the methods was calculated with the intraclass correlation coefficient (ICC) and depicted in Bland-Altman plots. All methods presented a linear pattern of surface loss measurements throughout the experiment, leading overall to a strong, statistically significant correlation between the methods (ICC = 0.85; p<0.001). So, despite the different surface loss values, all methods presented consistent results for surface loss measurement

    Thermoset Shape Memory Polymer Variable Stiffness 4D Robotic Catheters

    Get PDF
    Variable stiffness catheters are typically composed of an encapsulated core. The core is usually composed of a low melting point alloy (LMPA) or a thermoplastic polymer (TP). In both cases, there is a need to encapsulate the core with an elastic material. This imposes a limit to the volume of variable stiffness (VS) material and limits miniaturization. This paper proposes a new approach that relies on the use of thermosetting materials. The variable stiffness catheter (VSC) proposed in this work eliminates the necessity for an encapsulation layer and is made of a unique biocompatible thermoset polymer with an embedded heating system. This significantly reduces the final diameter, improves manufacturability, and increases safety in the event of complications. The device can be scaled to sub-millimeter dimensions, while maintaining a high stiffness change. In addition, integration into a magnetic actuation system allows for precise actuation of one or multiple tools
    • …
    corecore