2,358 research outputs found

    Examining CP Symmetry in Strange Baryon Decays

    Full text link
    Non-conservation of CP symmetry can manisfest itself in non-leptonic hyperon decays as a difference in the decay parameter between the strange-baryon decay and its charge conjugate. By comparing the decay distribution in the Λ\Lambda helicity frame for the decay sequence ΞΛπ\Xi^{-} \to \Lambda \pi^{-}, Λpπ\Lambda \to p \pi^{-} with that of Ξˉ+\bar{\Xi}^{+} decay, E756 at Fermilab did not observe any CP-odd effect at the 10210^{-2} level. The status of a follow-up experiment, HyperCP (FNAL E871), to search for CP violation in charged ΞΛ\Xi-\Lambda decay with a sensitivity of 10410^{-4} is also presented.Comment: 9 pages, 4 figures, invited talk presented at the Third International Conference on B Physics and CP Violation, 3-7 Dec 1999, Taipei, Taiwa

    The Radon Monitoring System in Daya Bay Reactor Neutrino Experiment

    Full text link
    We developed a highly sensitive, reliable and portable automatic system (H3^{3}) to monitor the radon concentration of the underground experimental halls of the Daya Bay Reactor Neutrino Experiment. H3^{3} is able to measure radon concentration with a statistical error less than 10\% in a 1-hour measurement of dehumidified air (R.H. 5\% at 25^{\circ}C) with radon concentration as low as 50 Bq/m3^{3}. This is achieved by using a large radon progeny collection chamber, semiconductor α\alpha-particle detector with high energy resolution, improved electronics and software. The integrated radon monitoring system is highly customizable to operate in different run modes at scheduled times and can be controlled remotely to sample radon in ambient air or in water from the water pools where the antineutrino detectors are being housed. The radon monitoring system has been running in the three experimental halls of the Daya Bay Reactor Neutrino Experiment since November 2013

    Further investigation on chaos of real digital filters

    Get PDF
    This Letter displays, via the numerical simulation of a real digital filter, that a finite-state machine may behave in a near-chaotic way even when its corresponding infinite-state machine does not exhibit chaotic behavior

    Measurement of Cosmic-ray Muons and Muon-induced Neutrons in the Aberdeen Tunnel Underground Laboratory

    Get PDF
    We have measured the muon flux and production rate of muon-induced neutrons at a depth of 611 m water equivalent. Our apparatus comprises three layers of crossed plastic scintillator hodoscopes for tracking the incident cosmic-ray muons and 760 L of gadolinium-doped liquid scintillator for producing and detecting neutrons. The vertical muon intensity was measured to be Iμ=(5.7±0.6)×106I_{\mu} = (5.7 \pm 0.6) \times 10^{-6} cm2^{-2}s1^{-1}sr1^{-1}. The yield of muon-induced neutrons in the liquid scintillator was determined to be Yn=(1.19±0.08(stat)±0.21(syst))×104Y_{n} = (1.19 \pm 0.08 (stat) \pm 0.21 (syst)) \times 10^{-4} neutrons/(μ\mu\cdotg\cdotcm2^{-2}). A fit to the recently measured neutron yields at different depths gave a mean muon energy dependence of Eμ0.76±0.03\left\langle E_{\mu} \right\rangle^{0.76 \pm 0.03} for liquid-scintillator targets.Comment: 14 pages, 17 figures, 3 table

    White Paper: Measuring the Neutrino Mass Hierarchy

    Full text link
    This white paper is a condensation of a report by a committee appointed jointly by the Nuclear Science and Physics Divisions at Lawrence Berkeley National Laboratory (LBNL). The goal of this study was to identify the most promising technique(s) for resolving the neutrino mass hierarchy. For the most part, we have relied on calculations and simulations presented by the proponents of the various experiments. We have included evaluations of the opportunities and challenges for these experiments based on what is available already in the literature.Comment: White paper prepared for Snowmass-201

    LArPix: Demonstration of low-power 3D pixelated charge readout for liquid argon time projection chambers

    Full text link
    We report the demonstration of a low-power pixelated readout system designed for three-dimensional ionization charge detection and digital readout of liquid argon time projection chambers (LArTPCs). Unambiguous 3D charge readout was achieved using a custom-designed system-on-a-chip ASIC (LArPix) to uniquely instrument each pad in a pixelated array of charge-collection pads. The LArPix ASIC, manufactured in 180 nm bulk CMOS, provides 32 channels of charge-sensitive amplification with self-triggered digitization and multiplexed readout at temperatures from 80 K to 300 K. Using an 832-channel LArPix-based readout system with 3 mm spacing between pads, we demonstrated low-noise (<<500 e^- RMS equivalent noise charge) and very low-power (<<100 μ\muW/channel) ionization signal detection and readout. The readout was used to successfully measure the three-dimensional ionization distributions of cosmic rays passing through a LArTPC, free from the ambiguities of existing projective techniques. The system design relies on standard printed circuit board manufacturing techniques, enabling scalable and low-cost production of large-area readout systems using common commercial facilities. This demonstration overcomes a critical technical obstacle for operation of LArTPCs in high-occupancy environments, such as the near detector site of the Deep Underground Neutrino Experiment (DUNE).Comment: 19 pages, 10 figures, 1 ancillary animation. V3 includes minor revisions based on referee comment

    The S-wave \Lambda\pi phase shift is not large

    Full text link
    We study the strong interaction S-wave \Lambda\pi phase shift in the region of the \Xi mass in the framework of a relativistic chiral unitary approach based on coupled channels. All parameters have been previously determined in a fit to strangeness S= -1 S-wave kaon-nucleon data. We find 0^\circ \le \delta_0 \le 1.1^\circ in agreement with previous chiral perturbation theory calculations (or extensions thereof). We also discuss why a recent coupled channel K-matrix calculation gives a result for \delta_0 that is negative and much bigger in magnitude. We argue why that value should not be trusted.Comment: 3 pages, REVTe
    corecore