356 research outputs found
A method to suppress dielectric breakdowns in liquid argon ionization detectors for cathode to ground distances of several millimeters
We present a method to reach electric field intensity as high as 400 kV/cm in
liquid argon for cathode-ground distances of several millimeters. This can be
achieved by suppressing field emission from the cathode, overcoming limitations
that we reported earlier
Experimental study of electric breakdowns in liquid argon at centimeter scale
In this paper we present results on measurements of the dielectric strength
of liquid argon near its boiling point and cathode-anode distances in the range
of 0.1 mm to 40 mm with spherical cathode and plane anode. We show that at such
distances the applied electric field at which breakdowns occur is as low as 40
kV/cm. Flash-overs across the ribbed dielectric of the high voltage
feed-through are observed for a length of 300 mm starting from a voltage of 55
kV. These results contribute to set reference for the breakdown-free design of
ionization detectors, such as Liquid Argon Time Projection Chambers (LAr TPC)
Measurement of the drift field in the ARGONTUBE LAr TPC with 266~nm pulsed laser beams
ARGONTUBE is a liquid argon time projection chamber (LAr TPC) with a drift
field generated in-situ by a Greinacher voltage multiplier circuit. We present
results on the measurement of the drift-field distribution inside ARGONTUBE
using straight ionization tracks generated by an intense UV laser beam. Our
analysis is based on a simplified model of the charging of a multi-stage
Greinacher circuit to describe the voltages on the field cage rings
First Demonstration of a Pixelated Charge Readout for Single-Phase Liquid Argon Time Projection Chambers
Liquid Argon Time Projection Chambers (LArTPCs) have been selected for the
future long-baseline Deep Underground Neutrino Experiment (DUNE). To allow
LArTPCs to operate in the high-multiplicity near detector environment of DUNE,
a new charge readout technology is required. Traditional charge readout
technologies introduce intrinsic ambiguities, combined with a slow detector
response, these ambiguities have limited the performance of LArTPCs, until now.
Here, we present a novel pixelated charge readout that enables the full 3D
tracking capabilities of LArTPCs. We characterise the signal to noise ratio of
charge readout chain, to be about 14, and demonstrate track reconstruction on
3D space points produced by the pixel readout. This pixelated charge readout
makes LArTPCs a viable option for the DUNE near detector complex.Comment: 13 pages, 9 figure
On the Electric Breakdown in Liquid Argon at Centimeter Scale
We present a study on the dependence of electric breakdown discharge
properties on electrode geometry and the breakdown field in liquid argon near
its boiling point. The measurements were performed with a spherical cathode and
a planar anode at distances ranging from 0.1 mm to 10.0 mm. A detailed study of
the time evolution of the breakdown volt-ampere characteristics was performed
for the first time. It revealed a slow streamer development phase in the
discharge. The results of a spectroscopic study of the visible light emission
of the breakdowns complement the measurements. The light emission from the
initial phase of the discharge is attributed to electro-luminescence of liquid
argon following a current of drifting electrons. These results contribute to
set benchmarks for breakdown-safe design of ionization detectors, such as
Liquid Argon Time Projection Chambers (LAr TPC).Comment: Minor revision according to editor report. 17 pages, 15 figures, 2
tables. Turboencabulato
ArCLight - a Compact Dielectric Large-Area Photon Detector
ArCLight is a novel device for detecting scintillation light over large areas
with Photon Detection Efficiency (PDE) of the order of a few percent. Its
robust technological design allows for efficient use in large-volume particle
detectors, such as Liquid Argon Time Projection Chambers (LArTPCs) or liquid
scintillator detectors. Due to its dielectric structure it can be placed inside
volumes with high electric field. It could potentially replace vacuum
PhotoMultiplier Tubes (PMTs) in applications where high PDE is not required.
The photon detection efficiency for a 10x10cm2 detector prototype was measured
to be in the range of 0.8% to 2.2% across the active area
L'éducation interprofessionnelle pour tous... Une expérience de sensibilisation pour des étudiants vaudois en formation prégraduée [Interprofessional education for all... An awareness experience for undergraduate students in Vaud].
Recommended from our members
Reconstruction and measurement of (100) MeV energy electromagnetic activity from π0 arrow γγ decays in the MicroBooNE LArTPC
We present results on the reconstruction of electromagnetic (EM) activity from photons produced in charged current νμ interactions with final state π0s. We employ a fully-automated reconstruction chain capable of identifying EM showers of (100) MeV energy, relying on a combination of traditional reconstruction techniques together with novel machine-learning approaches. These studies demonstrate good energy resolution, and good agreement between data and simulation, relying on the reconstructed invariant π0 mass and other photon distributions for validation. The reconstruction techniques developed are applied to a selection of νμ + Ar → μ + π0 + X candidate events to demonstrate the potential for calorimetric separation of photons from electrons and reconstruction of π0 kinematics
Determination of muon momentum in the MicroBooNE LArTPC using an improved model of multiple Coulomb scattering
We discuss a technique for measuring a charged particle's momentum by means
of multiple Coulomb scattering (MCS) in the MicroBooNE liquid argon time
projection chamber (LArTPC). This method does not require the full particle
ionization track to be contained inside of the detector volume as other track
momentum reconstruction methods do (range-based momentum reconstruction and
calorimetric momentum reconstruction). We motivate use of this technique,
describe a tuning of the underlying phenomenological formula, quantify its
performance on fully contained beam-neutrino-induced muon tracks both in
simulation and in data, and quantify its performance on exiting muon tracks in
simulation. Using simulation, we have shown that the standard Highland formula
should be re-tuned specifically for scattering in liquid argon, which
significantly improves the bias and resolution of the momentum measurement.
With the tuned formula, we find agreement between data and simulation for
contained tracks, with a small bias in the momentum reconstruction and with
resolutions that vary as a function of track length, improving from about 10%
for the shortest (one meter long) tracks to 5% for longer (several meter)
tracks. For simulated exiting muons with at least one meter of track contained,
we find a similarly small bias, and a resolution which is less than 15% for
muons with momentum below 2 GeV/c. Above 2 GeV/c, results are given as a first
estimate of the MCS momentum measurement capabilities of MicroBooNE for high
momentum exiting tracks
- …
