44 research outputs found

    The Advice of the Ad-Hoc Working Group on Sampling and Monitoring to the Standing Committee on Drinking Water Concerning Sampling and Monitoring for the Revision of the Council Directive 98/83/EC

    Get PDF
    The scope of the Ad-Hoc Working Group on Sampling and Monitoring is to give advice on selection of sampling points, sample protocols and sample frequencies in the framework of the revision of the Council Directive 98/83/EC on the quality of water intended for human consumption (Drinking Water Directive). This group was installed by the Standing Committee on Drinking Water on 8 May 2007.JRC.I.5-Physical and chemical exposure

    Quantitative Microbial Risk Assessment as support for bathing waters profiling

    Get PDF
    Profiling bathing waters supported by Quantitative Microbial Risk Assessment (QMRA) is key to the WHO's recommendations for the 2020/2021 revision of the European Bathing Water Directive. We developed an areaspecific QMRA model on four pathogens, using fecal indicator concentrations (E. coil, enterococci) for calculating pathogen loads. The predominance of illness was found to be attributable to Human Adenovirus, followed by Salmonella, Vibrio, and Norovirus. Overall, the cumulative illness risk showed a median of around 1 case/10000 exposures. The risk estimates were strongly influenced by the indicators that were used, suggesting the need for a more detailed investigation of the different sources of fecal contamination. Area-specific threshold values for fecal indicators were estimated on a risk-basis by modelling the cumulative risk against E. coll. and enterococci concentrations. To improve bathing waters assessment, we suggest considering source apportionment locally estimating of pathogen/indicator ratios, and calculating site-specific indicators thresholds based on risk assessment

    Management of Microbiological Contamination of the Water Network of a Newly Built Hospital Pavilion

    Get PDF
    The good installation, as well as commissioning plan, of a water network is a crucial step in reducing the risk of waterborne diseases. The aim of this study was to monitor the microbiological quality of water from a newly built pavilion before it commenced operation. Overall, 91 water samples were tested for coliforms, Escherichia coli, enterococci, Pseudomonas aeruginosa and Legionella at three different times: T0 (without any water treatment), T1 (after treatment with hydrogen peroxide and silver ions at initial concentration of 20 mg/L and after flushing of water for 20 min/day for seven successive days) and T2 (15 days later). Coliforms were detected in 47.3% of samples at T0, 36.3% at T1 and 4.4% at T2. E. coli was isolated in 4.4% of the samples only at T1, while enterococci appeared in 12.1% of the samples at T1 and in 2.2% at T2. P. aeruginosa was isolated in 50.5% of the samples at T0, 29.7% at T1 and 1.1% at T2. Legionella pneumophila serogroup 8 was isolated in 80.2% of the samples at T0, 36.3% at T1 and 2.2% at T2. Our results confirmed the need for a water safety plan in new hospital pavilions to prevent the risk of waterborne diseases

    Impact of lockdown on the microbiological status of the hospital water network during COVID-19 pandemic

    Get PDF
    The COVID-19 pandemic started in China in early December 2019, and quickly spread around the world. The epidemic gradually started in Italy at the end of February 2020, and by May 31, 2020, 232,664 cases and 33,340 deaths were confirmed. As a result of this pandemic, the Italian Ministerial Decree issued on March 11, 2020, enforced lockdown; therefore, many social, recreational, and cultural centers remained closed for months. In Apulia (southern Italy), all non-urgent hospital activities were suspended, and some wards were closed, with a consequent reduction in the use of the water network and the formation of stagnant water. This situation could enhance the risk of exposure of people to waterborne diseases, including legionellosis. The purpose of this study was to monitor the microbiological quality of the water network (coliforms, E. coli, Enterococci, P. aeruginosa, and Legionella) in three wards (A, B and C) of a large COVID-19 regional hospital, closed for three months due to the COVID-19 emergency. Our study revealed that all three wards' water network showed higher contamination by Legionella pneumophila sg 1 and sg 6 at T1 (after lockdown) compared to the period before the lockdown (T0). In particular, ward A at T1 showed a median value = 5600 CFU/L (range 0-91,000 CFU/L) vs T0, median value = 75 CFU/L (range 0-5000 CFU/L) (p-value = 0.014); ward B at T1 showed a median value = 200 CFU/L (range 0-4200 CFU/L) vs T0, median value = 0 CFU/L (range 0-300 CFU/L) (p-value = 0.016) and ward C at T1 showed a median value = 175 CFU/L (range 0-22,000 CFU/L) vs T0, median value = 0 CFU/L (range 0-340 CFU/L) (p-value < 0.001). In addition, a statistically significant difference was detected in ward B between the number of positive water samples at T0 vs T1 for L. pneumophila sg 1 and sg 6 (24% vs 80% p-value < 0.001) and for coliforms (0% vs 64% p-value < 0.001). Moreover, a median value of coliform load resulted 3 CFU/100 ml (range 0-14 CFU/100 ml) at T1, showing a statistically significant increase versus T0 (0 CFU/100 ml) (p-value < 0.001). Our results highlight the need to implement a water safety plan that includes staff training and a more rigorous environmental microbiological surveillance in all hospitals before occupying a closed ward for a longer than one week, according to national and international guidelines

    Wastewater-based epidemiology for early warning of SARS-COV-2 circulation: A pilot study conducted in Sicily, Italy

    Get PDF
    There is increasing evidence of the use of wastewater-based epidemiology to integrate conventional monitoring assessing disease symptoms and signs of viruses in a specific territory. We present the results of SARS-CoV-2 environmental surveillance activity in wastewater samples collected between September 2020 and July 2021 in 9 wastewater treatment plants (WTPs) located in central and western Sicily, serving over 570,000 residents. The presence of SARS-CoV-2, determined in 206 wastewater samples using RT-qPCR assays, was correlated with the notified and geo-referenced cases on the areas served by the WTPs in the same study period. Overall, 51% of wastewater samples were positive. Samples were correlated with 33,807 SARS-CoV-2 cases, reported in 4 epidemic waves, with a cumulative prevalence of 5.9% among Sicilian residents. The results suggest that the daily prevalence of SARS-CoV-2 active cases was statistically significant and higher in areas with SARS-CoV-2 positive wastewater samples. According to these findings, the proposed method achieves a good sensitivity profile (78.3%) in areas with moderate or high viral circulation (≥133 cases/100,000 residents) and may represent a useful tool in the management of epidemics based on an environmental approach, although it is necessary to improve the accuracy of the process

    The rapid spread of SARS-COV-2 Omicron variant in Italy reflected early through wastewater surveillance

    Get PDF
    The SARS-CoV-2 Omicron variant emerged in South Africa in November 2021, and has later been identified worldwide, raising serious concerns. A real-time RT-PCR assay was designed for the rapid screening of the Omicron variant, targeting characteristic mutations of the spike gene. The assay was used to test 737 sewage samples collected throughout Italy (19/21 Regions) between 11 November and 25 December 2021, with the aim of assessing the spread of the Omicron variant in the country. Positive samples were also tested with a real-time RT-PCR developed by the European Commission, Joint Research Centre (JRC), and through nested RT-PCR followed by Sanger sequencing. Overall, 115 samples tested positive for Omicron SARS-CoV-2 variant. The first occurrence was detected on 7 December, in Veneto, North Italy. Later on, the variant spread extremely fast in three weeks, with prevalence of positive wastewater samples rising from 1.0% (1/104 samples) in the week 5–11 December, to 17.5% (25/143 samples) in the week 12–18, to 65.9% (89/135 samples) in the week 19–25, in line with the increase in cases of infection with the Omicron variant observed during December in Italy. Similarly, the number of Regions/Autonomous Provinces in which the variant was detected increased fromone in the first week, to 11 in the second, and to 17 in the last one. The presence of the Omicron variant was confirmed by the JRC real-time RT-PCR in 79.1% (91/115) of the positive samples, and by Sanger sequencing in 66% (64/97) of PCR amplicons

    Metodi di screening e conferma per la determinazione di cianotossine

    No full text
    This volume reports the state of knowledge on risk assessment on cyanobacteria and their toxins in water intended for human consumption. Specific tools are provided to define the probability of occurrence and the estimation of the potential impact of the phenomenon of massive contamination of cyanobacteria in reservoirs for the production of drinking water. Based on the scientific data and technical knowledge reported in the volume, the essential elements for structuring of the monitoring plans and measures for prevention and mitigation of risk throughout the drinking water supply chain are established. The legal framework on cyanobacteria impact is discussed, with the definition of national reference values for cyanotoxins in water intended for human consumption under DL.vo 31/2001 and subsequent amendments. The document is coordinated with the report Rapporti ISTISAN 11/35 Pt. 2, concerning the definition of guidelines for the cyanobacteria risk management in water for human consumption. This volume contains the Preface and the Presentation common to both parts as well as the details of the publication plan
    corecore