9 research outputs found

    Number of MG 63 cells on day 1, 3 and 7 (A, C, E), their spreading area (D) and their growth dynamics (B) on a standard polystyrene cell culture dish (PS), undoped NCD films (B_0) and NCD films doped with 133, 1000 and 6700 ppm of boron (B_133, B_1000 and B_6700, respectively).

    No full text
    <p>Mean ± S.E.M. from 3 experiments; each included 32 microphotographs (day 1 and 3) and 18 measurements in a hemocytometer (day 7) per experimental group). ANOVA, Student-Newman-Keuls method. Statistical significance: I, II, III, IV, V: <i>p</i>≤0.05 compared to the group labelled with the same Roman number.</p

    The cell population doubling time of MG 63 cells between days 1 and 3 (DT<sub>1–3</sub>), days 3 and 7 (DT<sub>3–7</sub>) and days 1 and 7 (DT<sub>1–7</sub>) after seeding on polystyrene culture dishes (PS) and NCD films doped with 0, 133, 1000 or 6700 ppm of boron.

    No full text
    <p>Mean ± S.E.M. from 3 experiments (in total, 9 measurements for each experimental group and time interval). ANOVA, Student-Newman-Keuls Method. Statistical significance: <b><sup>I, II, V</sup></b>: <i>p</i>≤0.05 compared to polystyrene, undoped NCD and NCD doped with 6700 ppm of B, respectively.</p

    Dependence of the surface parameters of the NCD samples on the boron doping level.

    No full text
    <p>*Values adjusted to the surface potential of gold.</p><p>For the NDP measurements, the accuracy can achieve 5% (which is the precision of the boron atoms in the etalon). However, the precision of the NDP technique also depends on other parameters, e.g. the stability of the neutron beam intensity, identical geometry of the etalon and the measured sample, etc. Realistically, the NDP data can be routinely measured with accuracy of 10% in our case.</p><p>For roughness, potential, phase and contact angle, the data is presented as Mean ± S.D. (Standard Deviation). In the case of roughness and AFM phase, each <i>rms</i> value was determined from 65 536 data points on each sample type. The mean and S.D. of <i>rms</i> values were calculated from 5 such measurements across the sample. In the case of surface potential, the mean and S.D. values were calculated from 65 536 measurements across each sample. The contact angle was calculated from fitting the curve of the water droplet, and the mean and S.D. values were calculated from 16 measurements for each sample type.</p><p>Statistical Analysis: ANOVA, Student-Newman-Keuls Method. Statistical significance: <sup>I, II, III, IV</sup>: <i>p</i>≤0.05 compared to the group labelled with the same Roman number.</p><p>For the room temperature electrical resistivity measurements, the accuracy is better than 1%.</p

    Concentration of β<sub>1</sub>-integrin adhesion receptors, integrin-associated focal adhesion proteins talin and vinculin, markers of osteogenic cell differentiation osteocalcin, alkaline phosphatase, collagen I and osteopontin, and immunoglobuline adhesion molecule ICAM-1, a marker of cell immune activation, in MG 63 cells on day 7 after seeding on polystyrene culture dishes (PS) and NCD films doped with 0, 133, 1000 or 6700 ppm of boron.

    No full text
    <p>Measured by ELISA per mg of protein. The absorbances are given as a percentage of the control values obtained on PS. Mean ± S.E.M. from 3 experiments (each included 12–16 measurements for each experimental group). ANOVA, Student-Newman-Keuls Method. Statistical significance: <sup>I, II, III, IV</sup>: <i>p</i>≤0.05 compared to the group labelled with the same Roman number.</p
    corecore