13 research outputs found

    A Compliant Control Method Based on Force Sensors on Robot End-effectors for Live-working

    Get PDF
    This paper proposes a force control method for the live-working robot. Some live- working task requires larger stiffness such as pushing and butting when replacing cross arm or insulator. Two arms are attached on the live-working robot to meet this requirement and other need for cooperation by two arms. The different kinematic structure of this two arms brings many difficulties to get the dynamic model of the total system. This problem is solved by the proposed control scheme, the main idea of which is two arms could be considered as one arm. The force control method for the exact force control is based on the compliant relationship of the dual arms and the environment. The developed control scheme is experimentally tested on the live-working robot, and the experimental investigation concerns it has short computation time and can successfully tracking force

    Adaptive Absolute Ego-Motion Estimation Using Wearable Visual-Inertial Sensors for Indoor Positioning

    No full text
    This paper proposes an adaptive absolute ego-motion estimation method using wearable visual-inertial sensors for indoor positioning. We introduce a wearable visual-inertial device to estimate not only the camera ego-motion, but also the 3D motion of the moving object in dynamic environments. Firstly, a novel method dynamic scene segmentation is proposed using two visual geometry constraints with the help of inertial sensors. Moreover, this paper introduces a concept of “virtual camera” to consider the motion area related to each moving object as if a static object were viewed by a “virtual camera”. We therefore derive the 3D moving object’s motion from the motions for the real and virtual camera because the virtual camera’s motion is actually the combined motion of both the real camera and the moving object. In addition, a multi-rate linear Kalman-filter (MR-LKF) as our previous work was selected to solve both the problem of scale ambiguity in monocular camera tracking and the different sampling frequencies of visual and inertial sensors. The performance of the proposed method is evaluated by simulation studies and practical experiments performed in both static and dynamic environments. The results show the method’s robustness and effectiveness compared with the results from a Pioneer robot as the ground truth

    A pleural drainage tube misplaced into the right atrium

    No full text

    Effects of SiC Fibers and Laminated Structure on Mechanical Properties of Ti–Al Laminated Composites

    No full text
    Ti/Ti–Al and SiCf-reinforced Ti/Ti–Al laminated composites were fabricated through vacuum hot-pressure using pure Ti foils, pure Al foils and SiC fibers as raw materials. The effects of SiC fiber and a laminated structure on the properties of Ti–Al laminated composites were studied. A novel method of fiber weaving was implemented to arrange the SiC fibers, which can guarantee the equal spacing of the fibers without introducing other elements. Results showed that with a higher exerted pressure, a more compact structure with fewer Kirkendall holes can be obtained in SiCf-reinforced Ti/Ti–Al laminated composites. The tensile strength along the longitudinal direction of fibers was about 400 ± 10 MPa, which was 60% higher compared with the fabricated Ti/Ti–Al laminated composites with the same volume fraction (60%) of the Ti layer. An in situ tensile test was adopted to observe the deformation behavior and fracture mechanisms of the SiCf-reinforced Ti/Ti–Al laminated composites. Results showed that microcracks first occurred in the Ti–Al intermetallic layer

    Molecular Simulation Study on the Microscopic Structure and Mechanical Property of Defect-Containing sI Methane Hydrate

    No full text
    The study of changes in the related mechanical property and microscopic structure of methane hydrate during the decomposition process are of vital significance to its exploitation and comprehensive utilization. This paper had employed the molecular dynamics (MD) method to investigate the influence of defects on the microscopic structure and mechanical property of the sI methane hydrate system, and to discover the mechanical property for the defect-containing hydrate system to maintain its brittle materials. Moreover, the stress-strain curve of each system was analyzed, and it was discovered that the presence of certain defects in the methane hydrate could promote its mechanical property; however, the system mechanical property would be reduced when the defects had reached a certain degree (particle deletion rate of 9.02% in this study). Besides, the microscopic structures of the sI methane hydrate before and after failure were analyzed using the F3 order parameter value method, and it was found that the F3 order parameters near the crack would be subject to great fluctuations at the time of failure of the hydrate structure. The phenomenon and conclusions drawn in this study provide a basis for the study of the microscopic structure and mechanical characteristics of methane hydrate

    18F‐FDG PET/CT predicts the role of neoadjuvant immunochemotherapy in the pathological response of esophageal squamous cell carcinoma

    No full text
    Abstract Background This study aimed to investigate the predictive value of 18F‐FDG PET/CT for pathological response after neoadjuvant immunochemotherapy (NICT) in patients with esophageal squamous cell carcinoma (ESCC). Methods The clinical data of 54 patients with ESCC who underwent two cycles of NICT followed by surgery were retrospectively analyzed. NICT consisted of PD‐1 blockade therapy combined with chemotherapy. 18F‐FDG PET/CT scans were performed before and after NICT. The pathological results after surgery were used to assess the degree of pathological response. The scan parameters of 18F‐FDG PET/CT and their changes before and after NICT were compared with the pathological response. Results Among the 54 patients, 10 (18.5%) achieved complete pathological response (pCR) and 21 (38.9%) achieved major pathological response (MPR). The post‐NICT scan parameters and their changes were significantly associated with the pathological response. In addition, the values of the changes in the scanned parameters before and after treatment can further predict the pathological response of the patient. Conclusion 18F‐FDG PET/CT is a useful tool to evaluate the efficacy of NICT and predict pathological response in patients with ESCC. The post‐NICT scan parameters and their changes can help identify patients who are likely to achieve pCR or MPR
    corecore