6,452 research outputs found

    Measuring the Magnetic Flux Density in the CMS Steel Yoke

    Full text link
    The Compact Muon Solenoid (CMS) is a general purpose detector, designed to run at the highest luminosity at the CERN Large Hadron Collider (LHC). Its distinctive features include a 4 T superconducting solenoid with 6-m-diameter by 12.5-m-length free bore, enclosed inside a 10000-ton return yoke made of construction steel. The return yoke consists of five dodecagonal three-layered barrel wheels and four end-cap disks at each end comprised of steel blocks up to 620 mm thick, which serve as the absorber plates of the muon detection system. Accurate characterization of the magnetic field everywhere in the CMS detector is required. To measure the field in and around the steel, a system of 22 flux-loops and 82 3-D Hall sensors is installed on the return yoke blocks. Fast discharges of the solenoid (190 s time-constant) made during the CMS magnet surface commissioning test at the solenoid central fields of 2.64, 3.16, 3.68 and 4.01 T were used to induce voltages in the flux-loops. The voltages are measured on-line and integrated off-line to obtain the magnetic flux in the steel yoke close to the muon chambers at full excitations of the solenoid. The 3-D Hall sensors installed on the steel-air interfaces give supplementary information on the components of magnetic field and permit to estimate the remanent field in steel to be added to the magnetic flux density obtained by the voltages integration. A TOSCA 3-D model of the CMS magnet is developed to describe the magnetic field everywhere outside the tracking volume measured with the field-mapping machine. The results of the measurements and calculations are presented, compared and discussed.Comment: 9 pages, 7 figures, 16 references, presented at the III International Conference on Superconductivity and Magnetism (ICSM-2012), Kumburgaz, Istanbul, Turkey, 29 April - 4 May 201

    Measuring the Magnetic Flux Density with Flux Loops and Hall Probes in the CMS Magnet Flux Return Yoke

    Full text link
    The Compact Muon Solenoid (CMS) is a general purpose detector, designed to run at the highest luminosity at the CERN Large Hadron Collider (LHC). Its distinctive features include a 4 T superconducting solenoid with 6-m-diameter by 12.5-m-length free bore, enclosed inside a 10,000-ton return yoke made of construction steel. The flux return yoke consists of five dodecagonal three-layered barrel wheels and four end-cap disks at each end comprised of steel blocks up to 620 mm thick, which serve as the absorber plates of the muon detection system. To measure the field in and around the steel, a system of 22 flux loops and 82 3-D Hall sensors is installed on the return yoke blocks. A TOSCA 3-D model of the CMS magnet is developed to describe the magnetic field everywhere outside the tracking volume that was measured with the field-mapping machine. The voltages induced in the flux loops by the magnetic flux changing during the CMS magnet standard ramps down are measured with six 16-bit DAQ modules. The off-line integration of the induced voltages reconstructs the magnetic flux density in the yoke steel blocks at the operational magnet current of 18.164 kA. The results of the flux loop measurements during three magnet ramps down are presented and discussed.Comment: 3 pages, 6 figures, presented at the IEEE Nuclear Science Symposium 2016 (NSS) in Strasbourg, France on November 3, 2016. arXiv admin note: text overlap with arXiv:1605.0877

    Flux Loop Measurements of the Magnetic Flux Density in the CMS Magnet Yoke

    Full text link
    The Compact Muon Solenoid (CMS) is a general purpose detector, designed to run at the highest luminosity at the CERN Large Hadron Collider (LHC). Its distinctive features include a 4 T superconducting solenoid with 6-m-diameter by 12.5-m-length free bore, enclosed inside a 10,000-ton return yoke made of construction steel. The return yoke consists of five dodecagonal three-layered barrel wheels and four end-cap disks at each end comprised of steel blocks up to 620 mm thick, which serve as the absorber plates of the muon detection system. To measure the field in and around the steel, a system of 22 flux loops and 82 3-D Hall sensors is installed on the return yoke blocks. A TOSCA 3-D model of the CMS magnet is developed to describe the magnetic field everywhere outside the tracking volume measured with the field-mapping machine. The first attempt is made to measure the magnetic flux density in the steel blocks of the CMS magnet yoke using the standard magnet discharge with the current ramp down speed of 1.5 A/s.Comment: 7 pages, 5 figures, presented at ISCM2016 - 5th International Conference on Superconductivity and Magnetism on April 28, 2016 at Fethiye, Turke

    Validation of the CMS Magnetic Field Map

    Full text link
    The Compact Muon Solenoid (CMS) is a general purpose detector, designed to run at the highest luminosity at the CERN Large Hadron Collider (LHC). Its distinctive features include a 4 T superconducting solenoid with 6-m-diameter by 12.5-m-length free bore, enclosed inside a 10,000-ton return yoke made of construction steel. The return yoke consists of five dodecagonal three-layered barrel wheels and four end-cap disks at each end comprised of steel blocks up to 620 mm thick, which serve as the absorber plates of the muon detection system. To measure the field in and around the steel, a system of 22 flux loops and 82 3-D Hall sensors is installed on the return yoke blocks. A TOSCA 3-D model of the CMS magnet is developed to describe the magnetic field everywhere outside the tracking volume measured with the field-mapping machine. The magnetic field description is compared with the measurements and discussed.Comment: 7 pages, 5 figures, presented at 4th International Conference on Superconductivity and Magnetism 2014, April 27 - May 2, 2014, Antalya, Turkey. arXiv admin note: substantial text overlap with arXiv:1605.08778; text overlap with arXiv:1212.165

    Physiological Profile of Male Competitive and Recreational Surfers

    Get PDF
    Surfing consists of both high- and low-intensity paddling of varying durations, using both the aerobic and anaerobic systems. Surf-specific physiological studies lack adequate group sample sizes, and V[Combining Dot Above]O2peak values are yet to determine the differences between competitive and recreational surfers. The purpose of this study was therefore to provide a comprehensive physiological profile of both recreational and competitive surfers. This multisite study involved 62 male surfers, recreational (n = 47) and competitive (n = 15). Anthropometric measurements were conducted followed by dual-energy x-ray absorptiometry, anaerobic testing and finally aerobic testing. V[Combining Dot Above]O2peak was significantly greater in competitive surfers than in recreational surfers (M = 40.71 ± 3.28 vs. 31.25 ± 6.31 ml·kg·min, p \u3c 0.001). This was also paralleled for anaerobic power (M = 303.93 vs. 264.58 W) for competitive surfers. Arm span and lean total muscle mass was significantly (p ≤ 0.01) correlated with key performance variables (V[Combining Dot Above]O2peak and anaerobic power). No significant (p ≥ 0.05) correlations were revealed between season rank and each of the variables of interest (V[Combining Dot Above]O2peak and anaerobic power). Key performance variables (V[Combining Dot Above]O2peak and anaerobic power) are significantly higher in competitive surfers, indicating that this is both an adaptation and requirement in this cohort. This battery of physiological tests could be used as a screening tool to identify an athlete\u27s weaknesses or strengths. Coaches and clinicians could then select appropriate training regimes to address weaknesses

    Measurement of the CMS Magnetic Field

    Full text link
    The measurement of the magnetic field in the tracking volume inside the superconducting coil of the Compact Muon Solenoid (CMS) detector under construction at CERN is done with a fieldmapper designed and produced at Fermilab. The fieldmapper uses 10 3-D B-sensors (Hall probes) developed at NIKHEF and calibrated at CERN to precision 0.05% for a nominal 4 T field. The precise fieldmapper measurements are done in 33840 points inside a cylinder of 1.724 m radius and 7 m long at central fields of 2, 3, 3.5, 3.8, and 4 T. Three components of the magnetic flux density at the CMS coil maximum excitation and the remanent fields on the steel-air interface after discharge of the coil are measured in check-points with 95 3-D B-sensors located near the magnetic flux return yoke elements. Voltages induced in 22 flux-loops made of 405-turn installed on selected segments of the yoke are sampled online during the entire fast discharge (190 s time-constant) of the CMS coil and integrated offline to provide a measurement of the initial magnetic flux density in steel at the maximum field to an accuracy of a few percent. The results of the measurements made at 4 T are reported and compared with a three-dimensional model of the CMS magnet system calculated with TOSCA.Comment: 4 pages, 5 figures, 15 reference

    KIF5A and the contribution of susceptibility genotypes as a predictive biomarker for multiple sclerosis

    Get PDF
    There is increasing interest in the development of multiple sclerosis (MS) biomarkers that reflect central nervous system tissue injury to determine prognosis. We aimed to assess the prognostic value of kinesin superfamily motor protein KIF5A in MS by measuring levels of KIF5A in cerebrospinal fluid (CSF) combined with analysis of single nucleotide polymorphisms (SNPs; rs12368653 and rs703842) located within a MS susceptibility gene locus at chromosome 12q13–14 region. Enzyme-linked immunosorbent assay was used to measure KIF5A in CSF obtained from two independent biobanks comprising non-inflammatory neurological disease controls (NINDC), clinically isolated syndrome (CIS) and MS cases. CSF KIF5A expression was significantly elevated in progressive MS cases compared with NINDCs, CIS and relapsing–remitting MS (RRMS). In addition, levels of KIF5A positively correlated with change in MS disease severity scores (EDSS, MSSS and ARMSSS), in RRMS patients who had documented disease progression at 2-year clinical follow-up. Copies of adenine risk alleles (AG/AA; rs12368653 and rs703842) corresponded with a higher proportion of individuals in relapse at the time of lumbar puncture (LP), higher use of disease-modifying therapies post LP and shorter MS duration. Our study suggests that CSF KIF5A has potential as a predictive biomarker in MS and further studies into the potential prognostic value of analysing MS susceptibility SNPs should be considered
    • …
    corecore