750 research outputs found

    High rate production of polarized 3He with meta-stability exchange method

    Full text link
    Keywords: polarized 3He, meta-stability exchange, infrared laserComment: 4 figures, submitted to J. Phys. Soc. Jpn

    NMR calibration of optical measurement of nuclear polarization in 3He

    Get PDF
    We have performed precise NMR measurements in order to calibrate a standard optical technique for measuring the polarization of 3He nuclei. This optical technique requires knowledge of the pressure-dependent relationship between the nuclear polarization and the degree of circular polarization of the 668-nm light emitted from a 3He discharge. We determined the nuclear polarization by comparing the adiabatic fast-passage NMR signal from samples of polarized 3He at pressures between 0.1 and 5 torr to an identical sample of water. For water, the polarization is known from statistical mechanics. The 3He is polarized using the metastability exchange technique for optical pumping of 3He. The accuracy of the calibration is ±2%, which is required for applications in nuclear physics

    Sub-Pixel Response Measurement of Near-Infrared Sensors

    Get PDF
    Wide-field survey instruments are used to efficiently observe large regions of the sky. To achieve the necessary field of view, and to provide a higher signal-to-noise ratio for faint sources, many modern instruments are undersampled. However, precision photometry with undersampled imagers requires a detailed understanding of the sensitivity variations on a scale much smaller than a pixel. To address this, a near-infrared spot projection system has been developed to precisely characterize near-infrared focal plane arrays and to study the effect of sub-pixel non uniformity on precision photometry. Measurements of large format near-infrared detectors demonstrate the power of this system for understanding sub-pixel response.Comment: 9 pages, 13 figures, submitted to PAS

    Momentum Transfer Dependence of Nuclear Transparency from the Quasielastic ^(12)C(e, e'p) Reaction

    Get PDF
    The cross section for quasielastic ^(12)C(e,e’p) scattering has been measured at momentum transfer Q^2=1, 3, 5, and 6.8 (GeV/c)^2. The results are consistent with scattering from a single nucleon as the dominant process. The nuclear transparency is obtained and compared with theoretical calculations that incorporate color transparency effects. No significant rise of the transparency with Q^2 is observed

    Simulation results for a low energy nuclear recoil yields measurement in liquid xenon using the MiX detector

    Full text link
    Measuring the scintillation and ionization yields of liquid xenon in response to ultra-low energy nuclear recoil events is necessary to increase the sensitivity of liquid xenon experiments to light dark matter. Neutron capture on xenon can be used to produce nuclear recoil events with energies below 0.30.3 keVNR_\text{NR} via the asymmetric emission of Îł\gamma rays during nuclear de-excitation. The feasibility of an ultra-low energy nuclear recoil measurement using neutron capture was investigated for the Michigan Xenon (MiX) detector, a small dual-phase xenon time projection chamber that is optimized for a high scintillation gain. Simulations of the MiX detector, a partial neutron moderator, and a pulsed neutron generator indicate that a population of neutron capture events can be isolated from neutron scattering events. Further, the rate of neutron captures in the MiX detector was optimized by varying the thickness of the partial neutron moderator, neutron pulse width, and neutron pulse frequency.Comment: 7 pages, 5 figures. LIDINE 2022 proceeding

    Updated Report Acceleration of Polarized Protons to 120-150 GeV/c at Fermilab

    Full text link
    The SPIN@FERMI collaboration has updated its 1991-95 Reports on the acceleration of polarized protons in Fermilab's Main Injector, which was commissioned by Fermilab. This Updated Report summarizes some updated Physics Goals for a 120-150 GeV/c polarized proton beam. It also contains an updated discussion of the Modifications and Hardware needed for a polarized beam in the Main Injector, along with an updated Schedule and Budget.Comment: 30 pages, 12 figure
    • …
    corecore