23 research outputs found

    Fluorescence as an alternative to light-scatter gating strategies to identify frozen–thawed cells with flow cytometry

    Get PDF
    AbstractFlow cytometry is a key instrument in biological studies, used to identify and analyze cells in suspension. The identification of cells from debris is commonly based on light scatter properties as it has been shown that there is a relationship between forward scattered light and cell volume and this has become common practice in flow cytometry. Cryobiological conditions induce changes in cells that alter their light scatter properties. Cells with membrane damage from freeze–thaw stress produce lower forward scatter signals and may fall below standard forward scatter thresholds. In contrast to light scatter properties that cannot identify damaged cells from debris, fluorescent dyes used in membrane integrity and mitochondrial polarization assays are capable of labeling and discriminating all cells in suspension. Under cryobiological conditions, isolating cell populations is more effectively accomplished by gating on fluorescence rather than light scatter properties. This study shows the limitations of using forward scatter thresholds in flow cytometry to identify and gate cells after exposure to a freeze–thaw protocol and demonstrates the use of fluorescence as an alternative means of identifying and analyzing cells

    Cryoprotectant kinetic analysis of a human articular cartilage vitrification protocol

    Get PDF
    AbstractWe recently published a protocol to vitrify human articular cartilage and a method of cryoprotectant removal in preparation for transplantation. The current study’s goal was to perform a cryoprotectant kinetic analysis and theoretically shorten the procedure used to vitrify human articular cartilage. First, the loading of the cryoprotectants was modeled using Fick’s law of diffusion, and this information was used to predict the kinetics of cryoprotectant efflux after the cartilage sample had been warmed. We hypothesized that diffusion coefficients obtained from the permeation of individual cryoprotectants into porcine articular cartilage could be used to provide a reasonable prediction of the cryoprotectant loading and of the combined cryoprotectant efflux from vitrified human articular cartilage. We tested this hypothesis with experimental efflux measurements. Osteochondral dowels from three patients were vitrified, and after warming, the articular cartilage was immersed in 3 mL X-VIVO at 4 °C in two consecutive solutions, each for 24 h, with the solution osmolality recorded at various times. Measured equilibrium values agreed with theoretical values within a maximum of 15% for all three samples. The results showed that diffusion coefficients for individual cryoprotectants determined from experiments with 2-mm thick porcine cartilage can be used to approximate the rate of efflux of the combined cryoprotectants from vitrified human articular cartilage of similar thickness. Finally, Fick’s law of diffusion was used in a computational optimization to shorten the protocol with the constraint of maintaining the theoretical minimum cryoprotectant concentration needed to achieve vitrification. The learning provided by this study will enable future improvements in tissue vitrification

    Osmotic Transport across Cell Membranes in Nondilute Solutions: A New Nondilute Solute Transport Equation

    Get PDF
    The fundamental physical mechanisms of water and solute transport across cell membranes have long been studied in the field of cell membrane biophysics. Cryobiology is a discipline that requires an understanding of osmotic transport across cell membranes under nondilute solution conditions, yet many of the currently-used transport formalisms make limiting dilute solution assumptions. While dilute solution assumptions are often appropriate under physiological conditions, they are rarely appropriate in cryobiology. The first objective of this article is to review commonly-used transport equations, and the explicit and implicit assumptions made when using the two-parameter and the Kedem-Katchalsky formalisms. The second objective of this article is to describe a set of transport equations that do not make the previous dilute solution or near-equilibrium assumptions. Specifically, a new nondilute solute transport equation is presented. Such nondilute equations are applicable to many fields including cryobiology where dilute solution conditions are not often met. An illustrative example is provided. Utilizing suitable transport equations that fit for two permeability coefficients, fits were as good as with the previous three-parameter model (which includes the reflection coefficient, σ). There is less unexpected concentration dependence with the nondilute transport equations, suggesting that some of the unexpected concentration dependence of permeability is due to the use of inappropriate transport equations

    Investigating membrane and mitochondrial cryobiological responses of HUVEC using interrupted cooling protocols

    Get PDF
    AbstractThe success of cryopreservation protocols is largely based on membrane integrity assessments after thawing, since membrane integrity can be considered to give an upper limit in assessment of cell viability and the plasma membrane is considered to be a primary site of cryoinjury. However, the exposure of cells to conditions associated with low temperatures can induce injury to cellular structure and function that may not be readily identified by membrane integrity alone. Interrupted cooling protocols (including interrupted slow cooling without a hold time (graded freezing), and interrupted rapid cooling with a hold time (two-step freezing)), can yield important information about cryoinjury by separating the damage that occurs upon cooling to (and possibly holding at) a critical intermediate temperature range from the damage that occurs upon plunging to the storage temperature (liquid nitrogen). In this study, we used interrupted cooling protocols in the absence of cryoprotectant to investigate the progression of damage to human umbilical vein endothelial cells (HUVEC), comparing an assessment of membrane integrity with a mitochondrial polarization assay. Additionally, the membrane integrity response of HUVEC to interrupted cooling was investigated as a function of cooling rate (for interrupted slow cooling) and hold time (for interrupted rapid cooling). A key finding of this work was that under slow cooling conditions which resulted in a large number of membrane intact cells immediately post thaw, mitochondria are predominantly in a non-functional depolarized state. This study, the first to look directly at mitochondrial polarization throughout interrupted cooling profiles and a detailed study of HUVEC response, highlights the complexity of the progression of cell damage, as the pattern and extent of cell injury throughout the preservation process differs by injury site
    corecore