13 research outputs found

    The effect of continuous liver normothermic machine perfusion on the severity of histological bile duct injury

    Get PDF
    Static Cold Storage (SCS) injures the bile duct, while the effect of Normothermic Machine Perfusion (NMP) is unknown. In a sub-study of the COPE trial on liver NMP, we investigated the impact of preservation type on histological bile duct injury score (BDIS). Transplants with at least one bile duct biopsy, either at end of preservation or 1 h post-reperfusion, were considered. BDIS was determined by assessing peribiliary glands injury, stromal and mural loss, haemorrhage, and thrombosis. A bivariate linear model compared BDIS (estimate, CI) between groups. Sixty-five transplants and 85 biopsies were analysed. Twenty-three grafts were preserved with SCS and 42 with NMP, with comparable baseline characteristics except for a shorter cold ischemic time in NMP. The BDIS increased over time regardless of preservation type (p = 0.04). The BDIS estimate was higher in NMP [8.02 (7.40–8.65)] than in SCS [5.39 (4.52–6.26), p < 0.0001] regardless of time. One patient in each group developed ischemic cholangiopathy, with a BDIS of 6 for the NMP-preserved liver. In six other NMP grafts, BDIS ranged 7–12 without development of ischemic cholangiopathy. In conclusion, BDIS increases over time, and the higher BDIS in NMP did not increase ischemic cholangiopathy. Thus, BDIS may overestimate this risk after liver NMP

    Lymphocytes from rheumatoid arthritis patients have elevated levels of intracellular peroxiredoxin 2, and a greater frequency of cells with exofacial peroxiredoxin 2, compared with healthy human lymphocytes

    Get PDF
    AbstractPeroxiredoxin 2 has immune regulatory functions, but its expression in human peripheral blood lymphocytes and levels in extracellular fluid in healthy subjects and rheumatoid arthritis patients are poorly described. In the present study, the median intracellular peroxiredoxin 2 protein content of lymphocytes from rheumatoid arthritis patients was more than two-fold higher compared with healthy subjects’ lymphocytes. Intracellular peroxiredoxin 3 levels were similar in healthy and rheumatoid arthritis lymphocytes. Flow cytometry detected peroxiredoxin 2 on the surface of ca. 8% of T cells and ca. 56% of B cells (median % values) of all subjects analyzed. Exofacial thioredoxin-1 was also observed. In the total lymphocyte population from rheumatoid arthritis patients, few cells (median, 6%) displayed surface peroxiredoxin 2. In contrast, a significantly increased proportion of interleukin-17+ve lymphocytes were exofacially peroxiredoxin 2+ve (median, 39%). Prdx2 was also detected in human extracellular fluids. We suggest that crucial inflammatory cell subsets, i.e. interleukin-17+ve T cells, exhibit increased exofacial redox-regulating enzymes and that peroxiredoxin 2 may be involved in the persistence of pro-inflammatory cells in chronic inflammation

    Hemodynamics and metabolic parameters in normothermic kidney preservation are linked with donor factors, perfusate cells, and cytokines

    No full text
    Kidney transplantation is the best renal-replacement option for most patients with end-stage renal disease. Normothermic machine preservation (NMP) of the kidney has been studied extensively during the last two decades and implemented in clinical trials. Biomarker research led to success in identifying molecules with diagnostic, predictive and therapeutic properties in chronic kidney disease. However, perfusate biomarkers and potential predictive mechanisms in NMP have not been identified yet. Twelve discarded human kidneys (n = 7 DBD, n = 5 DCD) underwent NMP for up to 24 h. Eight were perfused applying urine recirculation (URC), four with replacement of urine (UR) using Ringer's lactate. The aim of our study was to investigate biomarkers (NGAL, KIM-1, and L-FABP), cells and cytokines in the perfusate in context with donor characteristics, perfusate hemodynamics and metabolic parameters. Cold ischemia time did not correlate with any of the markers. Perfusates of DBD kidneys had a significantly lower number of leukocytes after 6 h of NMP compared to DCD. Arterial flow, pH, NGAL and L-FABP correlated with donor creatinine and eGFR. Arterial flow was higher in kidneys with lower perfusate lactate. Perfusate TNF-α was higher in kidneys with lower arterial flow. The cytokines IL-1β and GM-CSF decreased during 6 h of NMP. Kidneys with more urine output had lower perfusate KIM-1 levels. Median and 6-h values of lactate, arterial flow, pH, NGAL, KIM-1, and L-FABP correlated with each other indicating a 6-h period being applicable for kidney viability assessment. The study results demonstrate a comparable cytokine and cell profile in perfusates with URC and UR. In conclusion, clinically available perfusate and hemodynamic parameters correlate well with donor characteristics and measured biomarkers in a discarded human NMP model

    Ex situ hypothermic perfusion of nonhuman primate pancreas: A feasibility study

    No full text
    International audiencePancreatic static cold storage (SCS) is the gold-standard method for pancreas preservation. Our main objective was to evaluate feasibility of hypothermic perfusion (HP) of nonhuman primates' pancreases for potential organ transplantation. Seven baboon pancreases were tested. Animals were included in a study approved by the French Research Ministry of Health. Two groups were compared: the control group (n = 2) was preserved using conventional SCS for 24-h and the perfusion group (n = 5) used HP for 24-h, with three different perfusion pressures (PP): 15 (n = 3), 20 (n = 1), and 25 mm Hg (n = 1). In the control group, focal congestion of islets was observed after 6-h. At 24-h, ischemic necrosis and multifocal congestion also occurred. In the HP group, at 15 mm Hg PP, multifocal congestion of islets was present at 24-h. At 20 mm Hg PP, no ischemic necrosis was found after 6-h. At 12-h and 24-h, focal congestion of islets was seen. At 25 mm Hg PP, focal congestion of islets appeared after 12-h. Immunostaining for insulin, glucagon, and somatostatin was normal and similar in controls and perfused pancreas transplants even after 24-h. Apoptosis index represented by cleaved caspase 3 activity, was less than 1% in perfusion and control groups, even after 24-h. HP of nonhuman primate pancreas is feasible and not deleterious as far as 24-h compared to SCS. SCS for more than 12-h was harmful for the transplants. Systolic perfusion pressure between 15-20 mm Hg did not cause any pathological injury of the tested organs

    The role of flavin mononucleotide (FMN) as a potentially clinically relevant biomarker to predict the quality of kidney grafts during hypothermic (oxygenated) machine perfusion

    Get PDF
    Hypothermic machine perfusion (HMP) provides preservation superior to cold storage and may allow for organ assessment prior to transplantation. Since flavin mononucleotide (FMN) in perfusate has been proposed as a biomarker of organ quality during HMP of donor livers, the aim of this study was to validate FMN as a biomarker for organ quality in the context of HMP preserved kidneys. Perfusate samples (n = 422) from the paired randomised controlled COPE-COMPARE-trial, comparing HMP with oxygenation (HMPO2) versus standard HMP in kidneys, were used. Fluorescence intensity (FI) was assessed using fluorescence spectroscopy (excitation 450nm; emission 500-600nm) and validated by fluorospectrophotometer and targeted liquid chromatography mass spectrometry (LC-MS/MS). Fluorescence intensity (FI)(ex450;em500-600) increased over time during machine perfusion in both groups (p<0.0001). This increase was similar for both groups (p = 0.83). No correlation, however, was found between FI(ex450;em500-600) and post-transplant outcomes, including day 5 or 7 serum creatinine (p = 0.11; p = 0.16), immediate graft function (p = 0.91), creatinine clearance and biopsy-proven rejection at one year (p = 0.14; p = 0.59). LC-MS/MS validation experiments of samples detected FMN in only one perfusate sample, whilst the majority of samples with the highest fluorescence (n = 37/38, 97.4%) remained negative. In the context of clinical kidney HMP, fluorescence spectroscopy unfortunately appears to be not specific and probably unsuitable for FMN. This study shows that FMN does not classify as a clinically relevant predictive biomarker of kidney graft function after transplantation

    Perfusate Proteomes Provide Biological Insight Into Oxygenated Versus Standard Hypothermic Machine Perfusion in Kidney Transplantation

    No full text
    Objective: To provide mechanistic insight into key biological alterations in donation after circulatory death kidneys during continuous pefusion we performed mass spectrometry profiling of perfusate samples collected during a phase 3 randomized double-blind paired clinical trial of hypothermic machine perfusion with and without oxygen (COMPARE). Background: Despite the clinical benefits of novel perfusion technologies aiming to better preserve donor organs, biological processes that may be altered during perfusion have remained largely unexplored. The collection of serial perfusate samples during the COMPARE clinical trial provided a unique resource to study perfusate proteomic profiles, with the hypothesis that in-depth profiling may reveal biologically meaningful information on how donor kidneys benefit from this intervention. Methods: Multiplexed liquid chromatography-tandem mass spectrometry was used to obtain a proteome profile of 210 perfusate samples. Partial least squares discriminant analysis and multivariate analysis involving clinical and perfusion parameters were used to identify associations between profiles and clinical outcomes. Results: Identification and quantitation of 1716 proteins indicated that proteins released during perfusion originate from the kidney tissue and blood, with blood-based proteins being the majority. Data show that the overall hypothermic machine perfusion duration is associated with increasing levels of a subgroup of proteins. Notably, high-density lipoprotein and complement cascade proteins are associated with 12-month outcomes, and blood-derived proteins are enriched in the perfusate of kidneys that developed acute rejection. Conclusions: Perfusate profiling by mass spectrometry was informative and revealed proteomic changes that are biologically meaningful and, in part, explain the clinical observations of the COMPARE trial.</p

    Perfusate Proteomes Provide Biological Insight Into Oxygenated Versus Standard Hypothermic Machine Perfusion in Kidney Transplantation

    No full text
    Objective: To provide mechanistic insight into key biological alterations in donation after circulatory death kidneys during continuous pefusion we performed mass spectrometry profiling of perfusate samples collected during a phase 3 randomized double-blind paired clinical trial of hypothermic machine perfusion with and without oxygen (COMPARE). Background: Despite the clinical benefits of novel perfusion technologies aiming to better preserve donor organs, biological processes that may be altered during perfusion have remained largely unexplored. The collection of serial perfusate samples during the COMPARE clinical trial provided a unique resource to study perfusate proteomic profiles, with the hypothesis that in-depth profiling may reveal biologically meaningful information on how donor kidneys benefit from this intervention. Methods: Multiplexed liquid chromatography-tandem mass spectrometry was used to obtain a proteome profile of 210 perfusate samples. Partial least squares discriminant analysis and multivariate analysis involving clinical and perfusion parameters were used to identify associations between profiles and clinical outcomes. Results: Identification and quantitation of 1716 proteins indicated that proteins released during perfusion originate from the kidney tissue and blood, with blood-based proteins being the majority. Data show that the overall hypothermic machine perfusion duration is associated with increasing levels of a subgroup of proteins. Notably, high-density lipoprotein and complement cascade proteins are associated with 12-month outcomes, and blood-derived proteins are enriched in the perfusate of kidneys that developed acute rejection. Conclusions: Perfusate profiling by mass spectrometry was informative and revealed proteomic changes that are biologically meaningful and, in part, explain the clinical observations of the COMPARE trial.</p

    Proteo-metabolomics reveals compensation between ischemic and non-injured contralateral kidneys after reperfusion

    Get PDF
    Ischaemia and reperfusion injury (IRI) is the leading cause of acute kidney injury (AKI), which contributes to high morbidity and mortality rates in a wide range of injuries as well as the development of chronic kidney disease. The cellular and molecular responses of the kidney to IRI are complex and not fully understood. Here, we used an integrated proteomic and metabolomic approach to investigate the effects of IRI on protein abundance and metabolite levels. Rat kidneys were subjected to 45 min of warm ischaemia followed by 4 h and 24 h reperfusion, with contralateral and separate healthy kidneys serving as controls. Kidney tissue proteomics after IRI revealed elevated proteins belonging to the acute phase response, coagulation and complement pathways, and fatty acid (FA) signalling. Metabolic changes were already evident after 4 h reperfusion and showed increased level of glycolysis, lipids and FAs, whilst mitochondria! function and ATP production was impaired after 24 h. This deficit was partially compensated for by the contra lateral kidney. Such a metabolic balance counteracts for the developing energy deficit due to reduced mitochondria! function in the injured kidney

    Development of ex situ normothermic reperfusion as an innovative method to assess pancreases after preservation

    No full text
    International audienceStatic cold storage (SCS) is the standard method for pancreas preservation prior to transplantation; however, it does not permit organ assessment. Normothermic reperfusion (NR) is utilized clinically for other organs to assess viability. Our aim was to develop NR using normothermic machine perfusion technique to simulate reperfusion at the time of transplantation, enabling evaluation of oxygenated hypothermic machine perfusion (HMPO2) as a newer strategy to optimize pancreas preservation. 13 porcine pancreases procured after circulatory death were divided into 3 groups: 4 pancreases preserved using SCS, and 2 groups preserved by HMPO2 (n = 4 and n = 5, differing by type of preservation solution). Duration of perfusion or cold storage was 6 hours before the 1-hour assessment using NR. Outcome measures were perfusion characteristics, biochemistry and change in tissue water mass as oedema assessment. During NR, the HMPO2 groups demonstrated better perfusion characteristics, normal macroscopic appearances, decreased water mass and one HMPO2 group demonstrated a response to glucose stimulation. Conversely, the SCS group showed an increased water mass and developed early macroscopic appearances of oedema, interstitial haemorrhage and minimal portal outflow. This study suggests that ex situ assessment of pancreases by NR is promising, and that HMPO2 may be better than SCS
    corecore