36 research outputs found

    Magnetic Field Properties inside the Jet of Mrk 421: Multiwavelength Polarimetry Including the Imaging X-ray Polarimetry Explorer

    Full text link
    We conducted a polarimetry campaign from radio to X-ray wavelengths of the high-synchrotron-peak (HSP) blazar Mrk 421, including Imaging X-ray Polarimetry Explorer (IXPE) measurements on 2022 December 6-8. We detected X-ray polarization of Mrk 421 with a degree of ΠX\Pi_{\rm X}=14±\pm1%\% and an electric-vector position angle ψX\psi_{\rm X}=107±\pm3^{\circ} in the 2-8 keV band. From the time variability analysis, we find a significant episodic variation in ψX\psi_{\rm X}. During 7 months from the first IXPE pointing of Mrk 421 in 2022 May, ψX\psi_{\rm X} varied across the range of 0^{\circ} to 180^{\circ}, while ΠX\Pi_{\rm X} maintained similar values within \sim10-15%\%. Furthermore, a swing in ψX\psi_{\rm X} in 2022 June was accompanied by simultaneous spectral variations. The results of the multiwavelength polarimetry show that the X-ray polarization degree was generally \sim2-3 times greater than that at longer wavelengths, while the polarization angle fluctuated. Additionally, based on radio, infrared, and optical polarimetry, we find that rotation of ψ\psi occurred in the opposite direction with respect to the rotation of ψX\psi_{\rm X} over longer timescales at similar epochs. The polarization behavior observed across multiple wavelengths is consistent with previous IXPE findings for HSP blazars. This result favors the energy-stratified shock model developed to explain variable emission in relativistic jets. The accompanying spectral variation during the ψX\psi_{\rm X} rotation can be explained by a fluctuation in the physical conditions, e.g., in the energy distribution of relativistic electrons. The opposite rotation direction of ψ\psi between the X-ray and longer-wavelength polarization accentuates the conclusion that the X-ray emitting region is spatially separated from that at longer wavelengths.Comment: 17 pages, 13 figures, 4 tables; Accepted for publication in A&

    A New Technique for Removal of an Incarcerated Expandable Femoral Nail

    No full text
    Removal of intramedullary nails often is relegated to younger surgeons but may be difficult and challenging. We describe difficulties with removal of an incarcerated expandable femoral nail and a new technique for retrograde mobilization of an intramedullary nail through a small infrapatellar incision. No special device was necessary for successful implant removal

    Differences in hip fracture care in Europe: a systematic review of recent annual reports of hip fracture registries

    No full text
    Purpose!#!Hip fractures are of growing interest due to their increasing number, subsequent functional decline and high institutionalization rate of patients, mortality, and costs. Several process measurements are essential for hip fracture care. To compare and improve these, hip fracture registries in Europe became popular. This systematic review aims to describe the differences between hip fracture registries in Europe as well as the differences in hip fracture treatment between countries.!##!Methods!#!A systematic search using the keywords 'hip fracture' AND 'national' AND 'database OR audit OR registry OR register' was performed in PubMed, Embase and Cochrane Library according to PRISMA guidelines till 3rd December 2020. Recent annual reports of identified hip fracture registries in Europe were additionally identified in June 2021. Comparisons of most common case-mix, process and outcome measurements were performed.!##!Results!#!11 registries in Europe were identified. Differences were observed regarding inclusion criteria of the different registries. Comparison of the different registries was difficult due to differences in the way to report measurements. While mortality rates differed substantially between countries, most of the process measurements met recommendations according to recent guidelines.!##!Conclusion!#!Hip fracture registries were a valid tool to compare hospitals within one country. However, a comparison between registries of different countries should have also been easily possible. For this, the registries need to make their data easily accessible and further unify their way of measuring and reporting

    Case Report of a Traumatic Atlantoaxial Rotatory Subluxation with Bilateral Locked Cervical Facets: Management, Treatment, and Outcome

    No full text
    The aim was to report a rare case of isolated traumatic atlantoaxial rotatory subluxation without ligamentous injury. Management consisted of analgesia, sedation, and application of a halo skull traction device. After removing halo skull traction, full reduction and recovery were achieved without instability

    Biomechanical Assessment of Three Osteosynthesis Constructs by Periprosthetic Humerus Fractures

    No full text
    Background. Biomechanical stability assessment of 3 different constructs for proximal fixation of a locking compression plate (LCP) in treating a Worland type C periprosthetic fracture after total shoulder arthroplasty. Methods. 27 Worland type C fractures after shoulder arthroplasty in synthetic humeri were treated with 14-hole LCP that is proximally fixed using the following: (1) 1 × 1.5 mm cerclage wires and 2x unicortical-locking screws, (2) 3 × 1.5 mm cerclage wires, or (3) 2x bicortical-locking attachment plates. Torsional stiffness was assessed by applying an internal rotation moment of 5 Nm and then after unloading the specimen, an external rotation moment of 5 Nm at the same rate was applied. Axial stiffness was assessed by applying a 50 N preload, and then applying a cyclic load of 250 N, then increasing the load by 50 N each time, until a maximum axial load of 2500 N was reached or specimen failure occurred. Results. With regard to internal as well as external rotational stiffness, group 1 showed a mean stiffness of 0.37 Nm/deg and 0.57 Nm/deg, respectively, group 2 had a mean stiffness of 0.51 Nm/deg and 0.39 Nm/deg, respectively, while group 3 had a mean stiffness of 1.34 Nm/deg and 1.31 Nm/deg, respectively. Concerning axial stiffness, group 1 showed an average stiffness of 451.0 N/mm, group 2 had a mean stiffness of 737.5 N/mm, whereas group 3 had a mean stiffness of 715.8 N/mm. Conclusion. Group 3 displayed a significantly higher torsional stiffness while a comparable axial stiffness to group 2
    corecore