3,469 research outputs found

    Organs from animals for man

    Get PDF
    In the following review some of the problems of xenotransplantation shall be discussed, based on the few experimental data available so far and on reports in the literature describing investigations which may be of importance for xenotransplantation. The impact of gravity on the upright posture of man versus almost all other mammals, the dysfunction between enzymes and hormones in different species and the lack of interactions between interleukins, cytokines and vasoactive substances will be taken into consideration. The question must be asked whether different levels of carrier molecules or serum proteins play a role in the physiological network. Even though the development of transgenic animals or other imaginative manipulations may lead to the acceptance of any type of xenografted organ, it has to be established for how long the products of the xenografts are able to act in the multifactorial orchestra. We are far from understanding xenogeneic molecular mechanisms involved in toxicity, necrosis and apoptosis or even reperfusion injury and ischemia in addition to the immediate mechanisms of the hyperacute xenogeneic rejection. Here, cell adhesion, blood clotting and vasomotion collide and bring micro-and macrocirculation to a standstill. All types of xenogeneic immunological mechanisms studied so far were found to have a more serious impact than those seen in allogeneic transplantation. In addition we are now only beginning to understand that so-called immunological parameters in allogeneic mechanisms act also in a true physiological manner in the xenogeneic situation. These molecular mechanisms occur behind the curtain of hyperacute, accelerated, acute or chronic xenograft rejection of which only some folds have been lifted to allow glimpses of part of the total scene. Other obstacles are likely to arise when long-term survival is achieved. These obstacles include retroviral infections, transfer of prions and severe side effects of the massive immunosuppression which will be needed. Moral, ethical and religious concerns are under debate and the species-specific production of proteins of the foreign donor species developed for clinical use suddenly appears to be a greater problem than anticipated

    Holographic data storage in a DX-center material

    Get PDF
    We report on the optical storage of digital data in a semiconductor sample containing DX centers. The diffraction efficiency and the bit-error-rate performance of multiplexed data images are shown to agree well with a simple model of the material. Uniform storage without an exposure schedule is demonstrated. The volume sensitivity is found to be ~10^3 times that of LiNBO3:Fe. The importance of coherent addition of scattered light with diffracted light in holographic data storage is discussed

    On high-order pressure-robust space discretisations, their advantages for incompressible high Reynolds number generalised Beltrami flows and beyond

    Get PDF
    An improved understanding of the divergence-free constraint for the incompressible Navier--Stokes equations leads to the observation that a semi-norm and corresponding equivalence classes of forces are fundamental for their nonlinear dynamics. The recent concept of {\em pressure-robustness} allows to distinguish between space discretisations that discretise these equivalence classes appropriately or not. This contribution compares the accuracy of pressure-robust and non-pressure-robust space discretisations for transient high Reynolds number flows, starting from the observation that in generalised Beltrami flows the nonlinear convection term is balanced by a strong pressure gradient. Then, pressure-robust methods are shown to outperform comparable non-pressure-robust space discretisations. Indeed, pressure-robust methods of formal order kk are comparably accurate than non-pressure-robust methods of formal order 2k2k on coarse meshes. Investigating the material derivative of incompressible Euler flows, it is conjectured that strong pressure gradients are typical for non-trivial high Reynolds number flows. Connections to vortex-dominated flows are established. Thus, pressure-robustness appears to be a prerequisite for accurate incompressible flow solvers at high Reynolds numbers. The arguments are supported by numerical analysis and numerical experiments.Comment: 43 pages, 18 figures, 2 table

    Effect of time delay on feedback control of a flashing ratchet

    Full text link
    It was recently shown that the use of feedback control can improve the performance of a flashing ratchet. We investigate the effect of a time delay in the implementation of feedback control in a closed-loop collective flashing ratchet, using Langevin dynamics simulations. Surprisingly, for a large ensemble, a well-chosen delay time improves the ratchet performance by allowing the system to synchronize into a quasi-periodic stable mode of oscillation that reproduces the optimal average velocity for a periodically flashing ratchet. For a small ensemble, on the other hand, finite delay times significantly reduce the benefit of feedback control for the time-averaged velocity, because the relevance of information decays on a time scale set by the diffusion time of the particles. Based on these results, we establish that experimental use of feedback control is realistic.Comment: 6 pages, 6 figures, to appear in Europhysics Letter

    Breast cancer: Monitoring response to neoadjuvant chemotherapy using Tc-99m sestamibi scintimammography

    Get PDF
    Background: Aim of the study was to assess the value of scintimammography using Tc-99m sestamibi in the evaluation of tumor response to neoadjuvant chemotherapy. Material and Methods: Results were calculated for 9 patients undergoing neoadjuvant chemotherapy. Scintimammography using 740 MBq Tc-99m sestamibi was performed before, during and after chemotherapy, and sestamibi uptake was scored visually and semiquantitatively to evaluate tumor response. Results: In the case of complete response (n = 3) sestamibi uptake decreased 8 days after beginning neoadjuvant chemotherapy and normalized in the following course. Focal uptake decreased more slowly in patients with partial response (n = 3), who showed clear, persisting tracer accumulation after therapy. The patients without response (n = 3) showed a persisting high tumor activity even after chemotherapy was completed. Conclusions: The preliminary data suggest that in contrast to other imaging modalities scintimammography appears to yield early information regarding tumor response to neoadjuvant chemotherapy

    Low-lying fermion modes of Nf=2 improved Wilson fermions

    Get PDF
    We present preliminary results for the topological charge and susceptibility determined from the low-lying eigenmodes of the Wilson-Dirac operator. These modes have been computed on dynamical configurations with Nf=2 non-perturbatively improved Wilson fermions. We compare our results with the eigenmodes of fermions in the quenched approximation.Comment: Lattice2001(confinement), 3 pages, 5 Figure

    Optimizing Stimulation and Analysis Protocols for Neonatal fMRI

    Get PDF
    The development of brain function in young infants is poorly understood. The core challenge is that infants have a limited behavioral repertoire through which brain function can be expressed. Neuroimaging with fMRI has great potential as a way of characterizing typical development, and detecting abnormal development early. But, a number of methodological challenges must first be tackled to improve the robustness and sensitivity of neonatal fMRI. A critical one of these, addressed here, is that the hemodynamic response function (HRF) in pre-term and term neonates differs from that in adults, which has a number of implications for fMRI. We created a realistic model of noise in fMRI data, using resting-state fMRI data from infants and adults, and then conducted simulations to assess the effect of HRF of the power of different stimulation protocols and analysis assumptions (HRF modeling). We found that neonatal fMRI is most powerful if block-durations are kept at the lower range of those typically used in adults (full on/off cycle duration 25-30s). Furthermore, we show that it is important to use the age-appropriate HRF during analysis, as mismatches can lead to reduced power or even inverted signal. Where the appropriate HRF is not known (for example due to potential developmental delay), a flexible basis set performs well, and allows accurate post-hoc estimation of the HRF

    Mechanical coupling in flashing ratchets

    Full text link
    We consider the transport of rigid objects with internal structure in a flashing ratchet potential by investigating the overdamped behavior of a rod-like chain of evenly spaced point particles. In 1D, analytical arguments show that the velocity can reverse direction multiple times in response to changing the size of the chain or the temperature of the heat bath. The physical reason is that the effective potential experienced by the mechanically coupled objects can have a different symmetry than that of individual objects. All analytical predictions are confirmed by Brownian dynamics simulations. These results may provide a route to simple, coarse-grained models of molecular motor transport that incorporate an object's size and rotational degrees of freedom into the mechanism of transport.Comment: 9 pages, 10 figure
    corecore