5,185 research outputs found

    Desenho e representação gráfica: 1. Introdução ao desenho técnico

    Get PDF
    Neste texto faz-se uma breve apresentação e introdução ao desenho e representação gráfica, em que se foca o desenho técnico em particular.info:eu-repo/semantics/publishedVersio

    Analysis of Indoor Radon Distribution Within a Room By Means of Computational Fluid Dynamics (CFD) Simulation

    Get PDF
    Radon gas is recognized by international organizations such as the United States Environmental Protection Agency (US-EPA) as the main contributor of radiation environmental to which human beings are exposed. Therefore, the evaluation of indoor radon concentration is a matter of public interest. The emanation and the income of the gas inside a room will generate a negative impact on the quality of the air when the place is not properly ventilated. Understanding how this gas will be distributed inside the room will allow to predict the spatial and temporal variations of radon levels and identify these parameters will provide important information that researchers can be used for calculate radiation dose exposure. Consequently, this studies can prevent a health risk for the people that live or work within the room. Currently, several researchers use the technique called Computational Fluid Dynamics (CFD) to simulate the distribution of gas radon, making use of the various commercial programs that exist in the market. In this work, three simulations were developed in rooms that have a similar geometry but different dimensions, in order to observe how the gas is distributed inside a closed space and to analyze how this distribution varies when the volume of the place is increased. The results show that as the volume of the site increases the radon is mitigated more rapidly and therefore has lower levels of concentration of this gas, as long as the level of radon emanation is kept constant

    Optimization of the Position of the CR-39 Polycarbonate Sheet Inside the Solid State Track Detector “Measuring Device” Through Computational Fluid Dynamics Technique

    Get PDF
    The “measuring device” is one of the most reliable, efficient and economic indoor radon dosimeters that exist. This device was developed by the Proyecto de Aplicaciones de la Dosimetría (PAD) at the Physics Institute of UNAM (IF-UNAM) and consists of a transparent rigid plastic cup, a CR-39 polycarbonate sheet and a standard size metal clip that is used to hold the polycarbonate in the center of the cup. The cup is wrapped and covered with a low-density polyurethane protector in order to prevent the detector from being irradiated by ionizing particles found in the environment. In this work, an analysis was carried out that allowed to understand how the radon concentration on the polycarbonate sheet varies when its height is changed with respect to the base of the plastic cup, in order to understand what position increase the probability of interaction between radon and the surface of the detector. For the development of this work, four computational simulations were performed with the technique called Computational Fluid Dynamics (CFD). The results shows that as the CR-39 is positioned more closed to the base of the cup, the probability of interaction of the radon and the detector increase. Based on these results it is concluded that, when there is a limit in the time in which a measuring device can be placed in the zone where it is desired to quantify indoor radon, it is recommended to collocated the CR-39 at 1 cm with respect to the base of the cup

    A study on the dynamics of a study on the dynamics of spatial mechanisms with frictional spherical clearance joints

    Get PDF
    An investigation on the dynamic modeling and analysis of spatial mechanisms with spherical clearance joints including friction is presented. For this purpose, the ball and the socket which compose a spherical joint are modeled as two individual colliding components. The normal contact-impact forces that develop at the spherical clearance joint are determined by using a continuous force model. A continuous analysis approach is used here with a Hertzian based contact force model, which includes a dissipative term representing the energy dissipation during the contact process. The pseudo-penetration that occurs between the potential contact points of the ball and the socket surface, as well as the indentation rate play a crucial role in the evaluation of the normal contact forces. In addition, several different friction force models based on the Coulomb’s law are revisited in this work. The friction models utilized here can accommodate the various friction regimens and phenomena that take place at the contact interface between the ball and the socket. Both the normal and tangential contact forces are evaluated and included into the systems’ dynamics equation of motion, developed under the framework of multibody systems formulations. A spatial four bar mechanism, which includes a spherical joint with clearance, is used as an application example to examine and quantify the effects of various friction force models, clearance sizes, and the friction coefficients.The first author expresses his gratitude to the Portuguese Foundation for Science and Technology through the PhD grant (PD/BD/114154/2016). This work has been supported by the Portuguese Foundation for Science and Technology with the reference project UID/EEA/04436/2013, by FEDER funds through the COMPETE 2020 – Programa Operacional Competitividade e Internacionalização (POCI) with the reference project POCI-01-0145-FEDER-006941.info:eu-repo/semantics/publishedVersio

    Analysis and characterization of neutron scattering of a Linear Accelerator (LINAC) on medical applications.

    Get PDF
    In several theoretical and experimental studies, the topic of the undesirable generation of photoneutrons in rooms where a linear accelerator (LINAC) operates has been discussed. When energies above 10 MeV are used to produce X-rays and give radiotherapy treatment to patients resulting in additional radiation to patients. Accordingly, an analysis and characterization of the neutron scattering distribution on different zones in a treatment room contributes to evaluate the radiological health risk to patients, technical and other workers involved in treatment. For the evaluation, a device developed at the PAD-IFUNAM formed by a CR-39 detector enclosed by two 3mm thick acrylic plates was employed. To avoid environmental contamination, the CR-39 and the acrylics plates are enclosed in a round plastic box. Sixteen of these devices were settled in different places inside the treatment room, where a linear accelerator is used. The results show a significant concentration of neutron scattering in areas near the head of irradiation. The recommendation will be to evaluate the neutron scattering concentration in all rooms that’s operates a LINAC in order to verify the radiological health risk and to mitigate the neutron scattering when concentration levels are to high like those in our case, in order to avoid unnecessary exposition to patients and personnel in general

    Metodologia para o monitoramento de dados técnicos e econômicos em pisciculturas familiares.

    Get PDF
    Este documento apresenta uma metodologia para o monitoramento de dados técnicos e econômicos em piscicultura familiares, que visa orientar instituições de pesquisa e extensão para a coleta sistematizada e participativa de dados com a finalidade de caracterizar técnico e economicamente pisciculturas familiares. Esta metodologia foi desenvolvida a partir de uma experiência com produtores familiares da Região de Divinópolis, TO. Etapas como importância de um diagnóstico prévio, critérios para escolha dos produtores, grau de intervenção da equipe técnica nas unidades produtivas, escolha das variáveis a serem monitoradas e definição da frequência de medidas, escolha dos equipamentos e utensílios para a coleta dos dados, construção das planilhas de coleta de dados e treinamento dos produtores para coleta de dados são apresentadas e discutidas. Ressalta-se ainda que o desenvolvimento de uma atividade de monitoramento participativa, que tem na colaboração e comprometimento dos produtores o ponto principal para seu sucesso, deve considerar o envolvimento com a comunidade local como um dos pilares para seu bom desempenho em todas as etapas previstas.bitstream/item/108694/1/bpd4.pd

    The Indoor Radon Concentration within the Tunnels of the Cholula Pyramid Through a Nuclear Tracks Methodology

    Get PDF
    Global organizations, including the World Health Organization (WHO), the Environmental Protection Agency of the United States (US-EPA) and the European Atomic Energy Community (EURATOM) recognize that radon gas as one of the main contributors to environmental radiation exposure for humans. Accordingly, a study and analysis of the indoors radon concentrate in the Cholula Pyramid contributes to understand the Radon dynamic inside of the Pyramid tunnels and to evaluate the radiological health risk to visitors, archaeologists, anthropologists and persons who spend extended periods inside the Pyramid. In this paper, the radon measurements along the Pyramid tunnels are presented. The Nuclear Track Methodology (NTM) was chosen for the measurements, using a close end-cup device developed at the Dosimetry Application Project (DAP) of the Physics Institute UNAM, following very well established protocols for the chemical etching and reading with the Counting Analysis Digital Imaging System (CADIS). The Cholula Pyramid consists of eight stages of constructions, each built in different periods of time. Cholula Pyramid is recognized as the pyramid with the largest base in the World, with 400 meters per side and 65 meters high. The tunnels of the pyramid were built in 1931 by architect Ignacio Marquina, with the aim of exploring and studying the structure. The results show an important indoor radon concentration in the measured tunnels, several times higher than levels recommended by United States Environmental Protection Agency (US-EPA). The recommendation will be to mitigate the radon concentration levels, in order to avoid unnecessary exposition to the people

    Monitoramento de indicadores da qualidade de um Cambissolo sob sistemas de manejo da pecuária familiar na Serra do Sudeste, RS

    Get PDF
    bitstream/item/30288/1/boletim-37.pd
    corecore