7 research outputs found

    Multi-laboratory performance assessment of diffuse optics instruments: the BitMap exercise

    Full text link
    SIGNIFICANCE: Multi-laboratory initiatives are essential in performance assessment and standardization-crucial for bringing biophotonics to mature clinical use-to establish protocols and develop reference tissue phantoms that all will allow universal instrument comparison. AIM: The largest multi-laboratory comparison of performance assessment in near-infrared diffuse optics is presented, involving 28 instruments and 12 institutions on a total of eight experiments based on three consolidated protocols (BIP, MEDPHOT, and NEUROPT) as implemented on three kits of tissue phantoms. A total of 20 synthetic indicators were extracted from the dataset, some of them defined here anew. APPROACH: The exercise stems from the Innovative Training Network BitMap funded by the European Commission and expanded to include other European laboratories. A large variety of diffuse optics instruments were considered, based on different approaches (time domain/frequency domain/continuous wave), at various stages of maturity and designed for different applications (e.g., oximetry, spectroscopy, and imaging). RESULTS: This study highlights a substantial difference in hardware performances (e.g., nine decades in responsivity, four decades in dark count rate, and one decade in temporal resolution). Agreement in the estimates of homogeneous optical properties was within 12% of the median value for half of the systems, with a temporal stability of <5  %   over 1 h, and day-to-day reproducibility of <3  %  . Other tests encompassed linearity, crosstalk, uncertainty, and detection of optical inhomogeneities. CONCLUSIONS: This extensive multi-laboratory exercise provides a detailed assessment of near-infrared Diffuse optical instruments and can be used for reference grading. The dataset-available soon in an open data repository-can be evaluated in multiple ways, for instance, to compare different analysis tools or study the impact of hardware implementations

    Embolisation of internal carotid artery aneurysm using the double microcatheter technique : a case report

    No full text
    Background: A wide-necked aneurysm is defined as the one with a neck greater than 4 mm in diameter. Embolisation of wide-necked aneurysms is a great challenge for neuroradiologists. To overcome possible complications of endovascular treatment of this type of aneurysms, methods like intracranial stents, balloon remodelling, the double microcatheter and the microcatheter protective technique have been developed. Case Report: We report a case of embolisation of a 63-year-old woman with a wide-necked aneurysm using the double microcatheter technique. Introduction of the second microcatheter into the aneurysm allowed for crossing two coils and prevented protrusion into the parent vessel, which resulted in successful treatment without postprocedural complications. Both postembolic and follow-up angiography showed complete exclusion of the aneurysm. Conclusions: The double microcatheter technique, owing to creation of a stable coil frame across the neck of the aneurysm, is suitable for treatment of aneurysms with an adverse dome-to-neck ratio. This technique is easy to perform for an experienced neuroradiologist

    Study of thin, achromatic diffractive structures to focus terahertz radiation on a detector

    No full text
    Thin and lightweight achromatic focusing elements with F-number close to 1 are desirable in many practical applications. We present the idea to use diffractive structures designed to work for the substantially increased THz frequency range. The paper analyses mono- and multi-focal lenses forming point-like foci as well as axicon and light sword optical elements focusing THz radiation into line segments located along the optical axis. We consider diffractive elements in a form of the first and the second order kinoforms having various thicknesses. Designed and fabricated elements were numerically and experimentally examined to verify their achromatic functioning. We present point spread functions (XY scans) and 2D energy maps (XZ scans) for different THz frequencies. Moreover, a diagram of chromatic aberration is created by registering energy distribution along the optical axis for different frequencies. The distance corresponding to the highest energy is chosen for each frequency. Therefore, we can compare broadband working of designed structures. The spherical lens coded as kinoform of the second order provides the best broadband functioning, however it is two times thicker than structures providing extended depth of focus (light sword and axicon) working with slightly smaller efficiency but being much thinner

    Automatic air volume control system for ventilation of two patients using a single ventilator: a large animal model study

    No full text
    Abstract The COVID-19 pandemic outbreak led to a global ventilator shortage. Hence, various strategies for using a single ventilator to support multiple patients have been considered. A device called Ventil previously validated for independent lung ventilation was used in this study to evaluate its usability for shared ventilation. We performed experiments with a total number of 16 animals. Eight pairs of pigs were ventilated by a ventilator or anesthetic machine and by Ventil for up to 27 h. In one experiment, 200 ml of saline was introduced to one subject’s lungs to reduce their compliance. The experiments were analyzed in terms of arterial blood gases and respiratory parameters. In addition to the animal study, we performed a series of laboratory experiments with artificial lungs (ALs). The resistance and compliance of one AL (affected) were altered, while the tidal volume (TV) and peak pressure (Ppeak) in the second (unaffected) AL were analyzed. In addition, to assess the risk of transmission of pathogens between AL respiratory tracts, laboratory tests were performed using phantoms of virus particles. The physiological level of analyzed parameters in ventilated animals was maintained, except for CO2 tension, for which a permissive hypercapnia was indicated. Experiments did not lead to injuries in the animal’s lungs except for one subject, as indicated by CT scan analysis. In laboratory experiments, changes in TV and Ppeak in the unaffected AL were less than 11%, except for 2 cases where the TV change was 20%. No cross-contamination was found in simulations of pathogen transmission. We conclude that ventilation using Ventil can be considered safe in patients undergoing deep sedation without spontaneous breathing efforts

    A multi-laboratory comparison of photon migration instruments and their performances: the BitMap exercise

    Get PDF
    Performance assessment and standardization are indispensable for instruments of clinical relevance in general and clinical instrumentation based on photon migration/diffuse optics in particular. In this direction, a multi-laboratory exercise was initiated with the aim of assessing and comparing their performances. 29 diffuse optical instruments belonging to 11 partner institutions of a European level Marie Curie Consortium BitMap were considered for this exercise. The enrolled instruments covered different approaches (continuous wave, CW; frequency domain, FD; time domain, TD and spatial frequency domain imaging, SFDI) and applications (e.g. mammography, oximetry, functional imaging, tissue spectroscopy). 10 different tests from 3 well-accepted protocols, namely, the MEDPHOT, the BIP, and the nEUROPt protocols were chosen for the exercise and the necessary phantoms kits were circulated across labs and institutions enrolled in the study. A brief outline of the methodology of the exercise is presented here. Mainly, the design of some of the synthetic descriptors, (single numeric values used to summarize the result of a test and facilitate comparison between instruments) for some of the tests will be discussed.. Future actions of the exercise aim at deploying these measurements onto an open data repository and investigating common analysis tools for the whole datase

    Multi-laboratory performance assessment of diffuse optics instruments: the BitMap exercise.

    Get PDF
    SIGNIFICANCE: Multi-laboratory initiatives are essential in performance assessment and standardization-crucial for bringing biophotonics to mature clinical use-to establish protocols and develop reference tissue phantoms that all will allow universal instrument comparison. AIM: The largest multi-laboratory comparison of performance assessment in near-infrared diffuse optics is presented, involving 28 instruments and 12 institutions on a total of eight experiments based on three consolidated protocols (BIP, MEDPHOT, and NEUROPT) as implemented on three kits of tissue phantoms. A total of 20 synthetic indicators were extracted from the dataset, some of them defined here anew. APPROACH: The exercise stems from the Innovative Training Network BitMap funded by the European Commission and expanded to include other European laboratories. A large variety of diffuse optics instruments were considered, based on different approaches (time domain/frequency domain/continuous wave), at various stages of maturity and designed for different applications (e.g., oximetry, spectroscopy, and imaging). RESULTS: This study highlights a substantial difference in hardware performances (e.g., nine decades in responsivity, four decades in dark count rate, and one decade in temporal resolution). Agreement in the estimates of homogeneous optical properties was within 12% of the median value for half of the systems, with a temporal stability of <5  %   over 1 h, and day-to-day reproducibility of <3  %  . Other tests encompassed linearity, crosstalk, uncertainty, and detection of optical inhomogeneities. CONCLUSIONS: This extensive multi-laboratory exercise provides a detailed assessment of near-infrared Diffuse optical instruments and can be used for reference grading. The dataset-available soon in an open data repository-can be evaluated in multiple ways, for instance, to compare different analysis tools or study the impact of hardware implementations
    corecore