14 research outputs found
Modeling operation mode of pellet boilers for residential heating
In recent years the consumption of wood pellets as energy source for residential heating has increased, not only as fuel for stoves, but also for small-scale residential boilers that produce hot water used for both space heating and domestic hot water.
Reduction of fuel consumption and pollutant emissions (CO, dust, HC) is an obvious target of wood pellet boiler manufacturers, however they are also quite interested in producing low-maintenance appliances. The need of frequent maintenance turns in higher operating costs and inconvenience for the user, and in lower boiler efficiency and higher emissions also.The aim of this paper is to present a theoretical model able to simulate the dynamic behavior of a pellet boiler. The model takes into account many features of real pellet boilers. Furthermore, with this model, it is possible to pay more attention to the influence of the boiler control strategy. Control strategy evaluation is based not only on pellet consumption and on total emissions, but also on critical operating conditions such as start-up and stop or prolonged operation at substantially reduced power level. Results are obtained for a residential heating system based on a wood pellet boiler coupled with a thermal energy storage.
Results obtained so far show a weak dependence of performance - in terms of fuel consumption and total emissions - on control strategy, however some control strategies present some critical issues regarding maintenance frequency
The Effect of Flue Gas Recirculation on CO, PM and NO<sub>x</sub> Emissions in Pellet Stove Combustion
Pellet stoves are popular appliances because they are an affordable technology and because the fuel is easy to store and to use. The increasing concern for environmental issues, however, requires a continuous effort to reduce pollutant levels in the atmosphere. This experimental work focuses on flue gas recirculation (FGR) as a possible way to improve combustion and decrease the emissions of carbon monoxide CO, particulate matter PM, and nitrogen oxides NOx in order to fulfill European and Italian emission requirements, for NOx in particular. A pellet stove has been tested in several experimental sessions with and without FGR. Pollutant emissions have been measured and analyzed in terms of statistical summaries and instantaneous trends. With FGR, the average CO and PM emissions were found to be 80% and 45% lower than the corresponding emissions without FGR. Results for PM are significant since FGR reduces emissions well below the most restrictive limits enforced in Italy. The analysis of instantaneous emissions in relation to excess air indicated that FGR can considerably reduce emissions, especially at the extremities of the oxygen O2 content range. Optimal ranges of excess air, in terms of O2 in flue gas, were identified for both the tested configurations, in which CO and PM emissions are minimized. The optimal range is 8–9% without FGR, and it decreases to 5–7% with FGR. Finally, a reduction in NOx emissions by about 11% has been observed in the configuration with FGR. Although this reduction seems modest as compared to CO and PM, it is important in that it lowers the emission level to the most severe limit in Italian regulations and indicates an improved FGR system as the solution for further reduction
Design of a 5th Generation District Heating Substation Prototype for a Real Case Study
The evolution of district heating networks is moving toward low temperatures in heat distribution with so called 4th generation networks. However, the lowest heat transfer fluid temperatures in district heating are achieved through ultra-low temperature networks, referred to as 5th generation district heating networks (5GDHNs). Low temperatures in heat distribution results in an extremely different configuration of 5GDHN compared to traditional district heating network, especially in the grid substation due to the inability to directly couple the grid with the buildings. This paper presents a detailed design of a 5th generation substation prototype, which is carried out to verify the proper operation and monitor the performance of this type of substation in a real case study. The prototype is fed by low-temperature waste heat, currently dissipated through evaporative towers, and will be built in the city of Brescia, Italy. The layout of the substation prototype, consisting of a bidirectional pumping system, a reversible water-to-water heat pump, an inertial thermal energy storage and a heat exchanger, is presented. An analysis is performed to figure out which refrigerant offers the best performance of the heat pump. In addition, fixed the refrigerant, the performance of the grid connected heat pump is found to be increased from 29.5% to 55.5% for both heating and cooling compared with a stand-alone air-to-water heat pump solution. Finally, the process flow diagram and the piping and instrumentation diagram of the substation are presented and commented
Design of a 5th Generation District Heating Substation Prototype for a Real Case Study
The evolution of district heating networks is moving toward low temperatures in heat distribution with so called 4th generation networks. However, the lowest heat transfer fluid temperatures in district heating are achieved through ultra-low temperature networks, referred to as 5th generation district heating networks (5GDHNs). Low temperatures in heat distribution results in an extremely different configuration of 5GDHN compared to traditional district heating network, especially in the grid substation due to the inability to directly couple the grid with the buildings. This paper presents a detailed design of a 5th generation substation prototype, which is carried out to verify the proper operation and monitor the performance of this type of substation in a real case study. The prototype is fed by low-temperature waste heat, currently dissipated through evaporative towers, and will be built in the city of Brescia, Italy. The layout of the substation prototype, consisting of a bidirectional pumping system, a reversible water-to-water heat pump, an inertial thermal energy storage and a heat exchanger, is presented. An analysis is performed to figure out which refrigerant offers the best performance of the heat pump. In addition, fixed the refrigerant, the performance of the grid connected heat pump is found to be increased from 29.5% to 55.5% for both heating and cooling compared with a stand-alone air-to-water heat pump solution. Finally, the process flow diagram and the piping and instrumentation diagram of the substation are presented and commented
A Review of Recent Literature on Systems and Methods for the Control of Thermal Comfort in Buildings
Thermal comfort in indoor environments is perceived as an important factor for the well-being and productivity of the occupants. To practically create a comfortable environment, a combination of models, systems, and procedures must be applied. This systematic review collects recent studies proposing complete thermal-comfort-based control strategies, extracted from a scientific database for the period 2017–2021. The study consists of this paper and of a spreadsheet recording all the 166 reviewed works. After a general introduction, the content of the papers is analyzed in terms of thermal comfort models, indoor environment control strategies, and correlation between these two aspects. Practical considerations on scope, required inputs, level of readiness, and, where available, estimated cost are also given. It was found that the predicted mean vote is the preferred thermal comfort modeling approach, followed by data-driven and adaptive methods. Thermal comfort is controlled mainly through indoor temperature, although a wide range of options are explored, including the comfort-based design of building elements. The most popular field of application of advanced control strategies is office/commercial buildings with air conditioning systems, which can be explained by budget and impact considerations. The analysis showed that few works envisaging practical implementations exist that address the needs of vulnerable people. A section is, therefore, dedicated to this issue
Effects of quenching rate and viscosity on spinodal decomposition
Spinodal decomposition of deeply quenched mixtures is studied experimentally, with particular emphasis on the domain growth rate during the late stage of coarsening. We provide some experimental evidence that at high PĂ©clet number, the process is isotropic and the domain growth is linear in time, even at finite quenching rates. In fact, the quenching rate appears to influence the magnitude of the growth rate, but not its scaling law. In the second part of the work we analyze the effect of viscosity on the growth rate. As predicted by the diffuse interface model, we do not find any effect of viscosity on the growth rate of the nucleating drops, although, as expected, the viscosity of the continuous phase does influence the settling speed and thus the total separation time