6,627 research outputs found

    Scalar Field Theory at Finite Temperature in D=2+1

    Get PDF
    We discuss the ϕ6\phi^6 theory defined in D=2+1D=2+1-dimensional space-time and assume that the system is in equilibrium with a thermal bath at temperature ÎČ−1\beta^{-1}. We use the 1/N 1/N expansion and the method of the composite operator (CJT) for summing a large set of Feynman graphs.We demonstrate explicitly the Coleman-Mermin-Wagner theorem at finite temperature.Comment: 12 pages, 1 figure. To be published in Journal Mathematical Physics, typos adde

    Classical Propagation of Strings across a Big Crunch/Big Bang Singularity

    Full text link
    One of the simplest time-dependent solutions of M theory consists of nine-dimensional Euclidean space times 1+1-dimensional compactified Milne space-time. With a further modding out by Z_2, the space-time represents two orbifold planes which collide and re-emerge, a process proposed as an explanation of the hot big bang. When the two planes are near, the light states of the theory consist of winding M2-branes, describing fundamental strings in a particular ten-dimensional background. They suffer no blue-shift as the M theory dimension collapses, and their equations of motion are regular across the transition from big crunch to big bang. In this paper, we study the classical evolution of fundamental strings across the singularity in some detail. We also develop a simple semi-classical approximation to the quantum evolution which allows one to compute the quantum production of excitations on the string and implement it in a simplified example.Comment: 38 pages, 19 figure

    Effect of Cross-Linking on the Electrical Properties of LDPE and its Lightning Impulse Ageing Characteristics

    No full text
    Cross-linked polyethylene (XLPE) is commonly used within high voltage cable insulation. It has improved thermal and mechanical resistance compared to normal low density polyethylene (LDPE). However, the cross-linking process may also vary the electrical characteristics of the material. This paper investigates changes in electrical properties of one type of LDPE before and after cross-linking. The effective lightning resistance is also considered, as the application of repetitive lightning impulse overvoltages can be a factor in insulation material ageing of high voltage cables. The material was cross-linked using trigonox-145 peroxide with controlled concentration. Samples were moulded to have a Rogowski profile and gold coated to make sure that they are evenly electrically stressed. Obtained results show that there are reductions in both space charge injection and the permittivity of the material after it is cross-linked. The breakdown strength of the material was also improved. However, the samples studied are more susceptible to ageing due to lightning impulses

    Decision making processes in people with symptoms of acute myocardial infarction: qualitative study

    Get PDF
    Objective To identify, the themes that influence decision making processes used by patients with symptoms of acute myocardial infarction. Design Qualitative study using semistructured interviews. Setting Two district hospitals in North Yorkshire. Participants 22 patients admitted to hospital with confirmed second, third, or fourth acute myocardial infarction. Main outcome measure Patients' perceptions of their experience between the onset of symptoms and the decision to seek medical help. Results Six main themes that influence the decision making process were identified: appraisal of In symptoms, perceived risk, previous experience, psychological and emotional factors, use of the NHS, and context of the event. Conclusions Knowledge of symptoms may not be enough to promote prompt action in the event of an acute myocardial infarction. Cognitive and emotional processes, individual beliefs and values, and the influence of the context of the event should also be considered in individual interventions designed to reduce delay in the event of symptoms of acute myocardial infarction

    Characterisation of untreated and treated biodegradable wastes

    Get PDF
    As part of a Defra sponsored project (WRT220), approximately 40 biodegradable wastes were characterised according to biodegradability (DR4 and BM100), total PTE content, C:N ratio and biochemical composition. Two leaching tests were employed; upflow percolation test and a one step LS10 test; eluates were analysed for TOC, pH, electrical conductivity, PTEs and a range of cations and anions. This paper contains a limited set of data for a selection of untreated and treated waste types representing four waste treatment processes (composting, MBT, MHT, anaerobic digestion). The DR4 and BM100 tests were found to be appropriate for a wide range of waste types but where possible they should be used in conjunction with other related tests. Longer-term MBT composting processes appeared to produce compost material with reduced ammonium concentrations and extractability of some PTEs. Carbon content (carbon analyzer - LECO) could be estimated as C = LOI/1.9 which is a routine operation. N LECO values were approximately 12% greater than the equivalent N Kjeldahl values

    Application of DR4 and BM100 Biodegradability tests to treated and untreated organic wastes

    Get PDF
    The aerobic DR4 and anaerobic BM100 biodegradability tests are currently applied in England and Wales for monitoring the reduction in biological municipal waste (BMW) achieved by mechanical biological treatment (MBT) plants (Environment Agency 2005). The protocol is applied only when outputs are landfilled and is based on estimating the reduction in potential biogas production between the MBT input, municipal solid waste (MSW), and all of the landfilled outputs, using the BM100 test. As this is a long term 100 day test the more rapid 4 day DR4 test may also be applied as this has been shown to correlate with the BM100 test. We have now applied the DR4 and BM100 tests to 132 organic waste samples including untreated and treated BMW and specific organic wastes. The results indicate that the correlation between the DR4 and BM100 tests has proved valid for mixed MSW derived BMW wastes. However when both tests are applied to specific organic wastes such as turkey feathers, cardboard packaging waste and pizza food wastes the correlation between the tests is less strong. It is concluded that the use of the DR4 and BM100 test correlation is valid for its designed application (monitoring MBT processes treating MSW derived mixed BMW), but that caution should be exercised when applying both tests to specific single component organic wastes

    Partial discharge analysis of defective three-phase cable

    No full text
    Power distribution cable networks represent a dynamic and complex challenge with regard to the issues of maintenance and providing a reliable, high quality supply of electrical power. Utilities historically used regular off-line testing to investigate the health of their assets. This method of testing is reasonably effective for this purpose but does have certain drawbacks associated with it; customer supply can be interrupted during the testing process and the cables are generally not tested under normal operating conditions. Meaning that the test data is not representative of the Partial discharge (PD) activity that is apparent under on-line conditions and the testing activity itself could trigger previously dormant PD sources. The modern approach for understanding the health of medium voltage (MV) cable distribution networks is to continuously monitor the assets whilst on-line. Analysis if the field data is then used to inform decisions regarding asset replacement and maintenance strategies. PD activity is widely recognised as a symptom linked to the degradation of the dielectric properties of high voltage plant. UK Power Networks sponsored research is being undertaken to investigate the evolution of PD activity within three-phase paper insulated lead covered (PILC) cables containing introduced defects. An experiment has been designed to stress cable lengths in a manner that is representative of the conditions met by on-line circuits [1]. A cable section containing a defect that is known to lead to the premature failure of in-service cables has been PD tested over a range of operating temperatures. The experiment utilizes three-phase energization at rated voltage as well as thermal cycling of the cable to replicate the daily load pattern experienced by circuits in the field. The extension to this work involves PD testing cable samples containing a range of defects to produce a data set consisting of PD pulses produced by varied sources. Analysis of this data should lead to a better understanding of the signals produced by the premature ageing of these types of cable

    The Nature of the Giant Outbursts in the Bursting Pulsar GRO J 1744-28

    Get PDF
    We investigate the possible role of an accretion disk instability in producing the giant outbursts seen in GRO J1744-28. Specifically, we study the global, time dependent evolution of the Lightman-Eardley instability which can develop near the inner edge of an accretion disk when the radiation pressure becomes comparable to the gas pressure. Broadly speaking, our results are compatible with earlier works by Taam \& Lin and by Lasota \& Pelat. The uniqueness of GRO J1744-28 appears to be associated with the constraint that, in order for outbursts to occur, the rate of accretion at the inner edge must be within a narrow range just above the critical accretion rate at which radiation pressure is beginning to become significant.Comment: 11 pages in .tex file, 4 Postscript figures, .tex file uses aasms.sty; Ap. J. L. 1996, in pres

    Network growth models and genetic regulatory networks

    Full text link
    We study a class of growth algorithms for directed graphs that are candidate models for the evolution of genetic regulatory networks. The algorithms involve partial duplication of nodes and their links, together with innovation of new links, allowing for the possibility that input and output links from a newly created node may have different probabilities of survival. We find some counterintuitive trends as parameters are varied, including the broadening of indegree distribution when the probability for retaining input links is decreased. We also find that both the scaling of transcription factors with genome size and the measured degree distributions for genes in yeast can be reproduced by the growth algorithm if and only if a special seed is used to initiate the process.Comment: 8 pages with 7 eps figures; uses revtex4. Added references, cleaner figure

    Transformer Oil Passivation and Impact of Corrosive Sulphur

    No full text
    In recent years a significant volume of research has been undertaken in order to understand the recent failures in oil insulated power apparatus due to deposition of copper sulphide on the conductors and in the insulation paper. Dibenzyl Disulfide (DBDS) has been found to be the leading corrosive sulphur compound in the insulation oil [1]. The process of copper sulphide formation and the deposition in the paper is still being investigated, but a recently proposed method seems to be gaining some confidence [1]. This method suggests a two-step process; initially the DBDS and some oil soluble copper complexes are formed. Secondly the copper complexes are absorbed in the paper insulation, where they then decompose into copper sulphide [2]. The most commonly used mitigating technique for corrosive sulphur contaminated oil is passivation, normally using Irgamet 39 or 1, 2, 3-benzotriazole (BTA). The passivator is diluted into the oil to a concentration of around 100ppm, where it then reacts with the copper conductors to form a complex layer around the copper, preventing it from interacting with DBDS compounds and forming copper sulphide. This research project will investigate the electrical properties of HV transformers which have tested positive for corrosive sulphur, and the evolution of those properties as the asset degrades due to sulphur corrosion. Parallel to this the long term properties of transformers with passivated insulation oil will be analysed in order to understand the passivator stability and whether it is necessary to keep adding the passivator to sustain its performance. Condition monitoring techniques under investigation will include dielectric spectroscopy, frequency response analysis, recovery voltage method (aka interfacial polarisation) amongst others. Partial discharge techniques will not be investigated, as the voltage between the coil plates is low and therefore it will not contribute significantly to the overall insulation breakdown, in corrosive oil related faults [3]. The goal of this research is to establish key electrical properties in both passivated and non-passivated power transformers that demonstrate detectable changes as the equipment degrades due to the insulation oil being corrosive
    • 

    corecore