132 research outputs found

    Impact of Anesthetic Management on Safety and Outcomes Following Mechanical Thrombectomy for Ischemic Stroke in SWIFT PRIME Cohort

    Get PDF
    Background and purpose: The optimal anesthetic management of acute ischemic stroke patients during mechanical thrombectomy (MT) remains controversial. In this post-hoc analysis, we investigated the impact of anesthesia type on clinical outcomes in patients included in SWIFT PRIME trial.Methods: Ninety-seven patients treated with MT were included. Patients treated in centers with general anesthesia (GA) policy (n = 32) were compared with those treated in centers with conscious sedation (CS) policy (n = 65). Primary outcomes studied included times to treatment initiation (TTI), rates of successful recanalization (TICI 2b/3), and functional independence (mRS 0–2 at 90 days). Secondary outcomes were adverse events, lowest systolic and diastolic blood pressures (LSBP and LDBP) during MT. Univariate analysis and multivariate regression logistic modeling were conducted.Results: The GA-policy and CS-policy groups presented comparable TTI (94 ± 36 min vs. 102 ± 48 min; p = 0.44), rates of TICI 2b/3 recanalization (22/32 [68.8%] vs. 51/65 [78.5%]; p = 0.32). CS-policy was associated to higher rate of functional independence than GA-policy, but the difference was not significant (43/65 [66.2%] vs. 16/32 [50.0%]; p = 0.18). GA-policy patients had a higher rate of postoperative pneumonia (11/32 [34.4%] vs. 8/65 [12.3%]; p = 0.02) and lower LSBP (110 [30,160] mmHg vs. 119 [77,170] mmHg; p = 0.03) and LDBP (55 (15,75) mmHg vs. 67 [40,121]; p < 0.001). When corrected for differences in baseline characteristics, GA-policy was associated with lower rate of functional independence (OR 0.32; p = 0.05). A 10-point increase in perprocedural LDBP was associated with an increased likelihood of favorable outcome (OR 1.51; p = 0.01).Conclusions: GA-policy for MT presented comparable TTI and rates of successful revascularization to CS-policy. However, GA-policy was associated with lower rates of functional independence and with higher incidence of perprocedural hypotension and postoperative pneumonia.Clinical Trial Registration: URL—http://www.clinicaltrials.gov. Unique identifier: NCT0165746

    The Natural Variation of a Neural Code

    Get PDF
    The way information is represented by sequences of action potentials of spiking neurons is determined by the input each neuron receives, but also by its biophysics, and the specifics of the circuit in which it is embedded. Even the “code” of identified neurons can vary considerably from individual to individual. Here we compared the neural codes of the identified H1 neuron in the visual systems of two families of flies, blow flies and flesh flies, and explored the effect of the sensory environment that the flies were exposed to during development on the H1 code. We found that the two families differed considerably in the temporal structure of the code, its content and energetic efficiency, as well as the temporal delay of neural response. The differences in the environmental conditions during the flies' development had no significant effect. Our results may thus reflect an instance of a family-specific design of the neural code. They may also suggest that individual variability in information processing by this specific neuron, in terms of both form and content, is regulated genetically

    Penumbral imaging and functional outcome in patients with anterior circulation ischaemic stroke treated with endovascular thrombectomy versus medical therapy: a meta-analysis of individual patient-level data

    Get PDF
    Background: CT perfusion (CTP) and diffusion or perfusion MRI might assist patient selection for endovascular thrombectomy. We aimed to establish whether imaging assessments of irreversibly injured ischaemic core and potentially salvageable penumbra volumes were associated with functional outcome and whether they interacted with the treatment effect of endovascular thrombectomy on functional outcome. Methods: In this systematic review and meta-analysis, the HERMES collaboration pooled patient-level data from all randomised controlled trials that compared endovascular thrombectomy (predominantly using stent retrievers) with standard medical therapy in patients with anterior circulation ischaemic stroke, published in PubMed from Jan 1, 2010, to May 31, 2017. The primary endpoint was functional outcome, assessed by the modified Rankin Scale (mRS) at 90 days after stroke. Ischaemic core was estimated, before treatment with either endovascular thrombectomy or standard medical therapy, by CTP as relative cerebral blood flow less than 30% of normal brain blood flow or by MRI as an apparent diffusion coefficient less than 620 μm2/s. Critically hypoperfused tissue was estimated as the volume of tissue with a CTP time to maximum longer than 6 s. Mismatch volume (ie, the estimated penumbral volume) was calculated as critically hypoperfused tissue volume minus ischaemic core volume. The association of ischaemic core and penumbral volumes with 90-day mRS score was analysed with multivariable logistic regression (functional independence, defined as mRS score 0–2) and ordinal logistic regression (functional improvement by at least one mRS category) in all patients and in a subset of those with more than 50% endovascular reperfusion, adjusted for baseline prognostic variables. The meta-analysis was prospectively designed by the HERMES executive committee, but not registered. Findings: We identified seven studies with 1764 patients, all of which were included in the meta-analysis. CTP was available and assessable for 591 (34%) patients and diffusion MRI for 309 (18%) patients. Functional independence was worse in patients who had CTP versus those who had diffusion MRI, after adjustment for ischaemic core volume (odds ratio [OR] 0·47 [95% CI 0·30–0·72], p=0·0007), so the imaging modalities were not pooled. Increasing ischaemic core volume was associated with reduced likelihood of functional independence (CTP OR 0·77 [0·69–0·86] per 10 mL, pinteraction=0·29; diffusion MRI OR 0·87 [0·81–0·94] per 10 mL, pinteraction=0·94). Mismatch volume, examined only in the CTP group because of the small numbers of patients who had perfusion MRI, was not associated with either functional independence or functional improvement. In patients with CTP with more than 50% endovascular reperfusion (n=186), age, ischaemic core volume, and imaging-to-reperfusion time were independently associated with functional improvement. Risk of bias between studies was generally low. Interpretation: Estimated ischaemic core volume was independently associated with functional independence and functional improvement but did not modify the treatment benefit of endovascular thrombectomy over standard medical therapy for improved functional outcome. Combining ischaemic core volume with age and expected imaging-to-reperfusion time will improve assessment of prognosis and might inform endovascular thrombectomy treatment decisions. Funding: Medtronic

    Imagine, Innovate, Inspire: Our Shared Journey in Neurosurgery

    No full text

    Advances in Interventional Neuroradiology 2006

    No full text

    The Trevo device: preclinical data of a novel stroke thrombectomy device in two different animal models of arterial thrombo-occlusive disease

    No full text
    BACKGROUND: The currently available mechanical devices fail to achieve recanalization in as many as 20-40% of proximal arterial occlusion strokes. OBJECTIVE: The preclinical evaluation of the safety and efficacy of a novel thrombectomy device designed to achieve immediate flow restoration by quickly removing clot is reported. METHODS: Four confirmatory animal studies were performed with the Trevo device (Concentric Medical Inc, Mountain View, California, USA) in the swine (n=2) and canine (n=1) models of arterial thrombo-occlusive disease employing autologous thrombin generated thrombi. The angiographic response and the degree of device-clot incorporation were evaluated. High resolution flat panel three-dimensional CT was performed to further define the in vivo device-thrombus-vessel interaction. Finally, samples of three swine vessels treated with six passes of the device were explanted for histopathological analysis. RESULTS: A total of 16 clots of variable hardness and consistency were implanted in a variety of vascular settings, including the swine internal maxillary, lingual and forelimb arteries as well as the canine external carotid and vertebral arteries. Thrombolysis in Myocardial Infarction (TIMI) 2-3 reperfusion was achieved in all cases immediately after device deployment. All 16 clots were retrieved after one (n=15) or two (n=1) passes with the device. Histopathological analysis demonstrated severe disruption of the intima but no hemorrhage of media or adventitia. CONCLUSION: The experimental data suggest that the Trevo device is highly effective at achieving immediate reperfusion of occluded arteries without causing any clinically significant disruption of vascular integrity
    • …
    corecore