11,725 research outputs found

    Keeping California cool: Recent cool community developments

    Get PDF
    In 2006, California introduced the Global Warming Solutions Act (Assembly Bill 32), which requires the state to reduce greenhouse gas emissions to 1990 levels by 2020. "Cool community" strategies, including cool roofs, cool pavements, cool walls and urban vegetation, have been identified as voluntary measures with potential to reduce statewide emissions. In addition, cool community strategies provide co-benefits for residents of California, such as reduced utility bills, improved air quality and enhanced urban livability. To achieve these savings, Lawrence Berkeley National Laboratory (LBNL) has worked with state and local officials, non-profit organizations, school districts, utilities, and manufacturers for 4 years to advance the science and implementation of cool community strategies. This paper summarizes the accomplishments of this program, as well as recent developments in cool community policy in California and other national and international efforts. We also outline lessons learned from these efforts to characterize successful programs and policies to be replicated in the future

    Comparison of software models for energy savings from cool roofs

    Get PDF
    A web-based Roof Savings Calculator (RSC) has been deployed for the United States Department of Energy as an industry-consensus tool to help building owners, manufacturers, distributors, contractors and researchers easily run complex roof and attic simulations. RSC simulates multiple roof and attic technologies for side-by-side comparison including reflective roofs, different roof slopes, above sheathing ventilation, radiant barriers, low-emittance roof surfaces, duct location, duct leakage rates, multiple substrate types, and insulation levels. Annual simulations of hour-by-hour, whole-building performance are used to provide estimated annual energy and cost savings from reduced HVAC use. While RSC reported similar cooling savings to other simulation engines, heating penalty varied significantly. RSC results show reduced cool roofing cost-effectiveness, thus mitigating expected economic incentives for this countermeasure to the urban heat island effect. This paper consolidates comparison of RSC's projected energy savings to other simulation engines including DOE-2.1E, AtticSim, Micropas, and EnergyPlus. Also included are comparisons to previous simulation-based studies, analysis of RSC cooling savings and heating penalties, the role of radiative heat exchange in an attic assembly, and changes made for increased accuracy of the duct model. Radiant heat transfer and duct interaction not previously modeled is considered a major contributor to heating penalties

    A Compact Fireball Model of Gamma Ray Bursts

    Get PDF
    It is proposed that the gamma ray burst photons near the peak of the spectrum at several hundred KeV are produced on very compact scales, where photon production is limited by blackbody effects and/or the requirement of energetic quanta (E>2mec2E>2m_e c^2) for efficient further production. The fast variation of order milliseconds in the time profile is then a natural expectation, given the other observed GRB parameters. Analytic calculations are presented to show that the escape of non-thermal, energetic gamma rays can emerge within a second of the thermal photons from a gammasphere of below 101210^{12} cm. The minimum asymptotic bulk Lorentz factor in this model is found to be of order several hundred if the photosphere is of order 3×10113 \times 10^{11} cm and greater for larger or smaller photospheric radii. It is suggested that prompt UHE gamma rays might provide a new constraint on the asymptotic Lorentz factor of the outflow.Comment: To appear in ApJ, revisions requested by the refere

    Realising the school science curriculum

    Get PDF
    This article identifies historical, pedagogical and epistemological problems which distance the school science curriculum from social questions, and issues of social justice more specifically. Drawing on a critical realist approach it addresses these problems and aims to demonstrate that social justice lies at the heart of inquiry in science in schools

    Thermal performance and energy savings of white and sedum-tray garden roof: A case study in a Chongqing office building

    Get PDF
    This study presents the experimental measurement of the energy consumption of three top-floor air-conditioned rooms in a typical office building in Chongqing, which is a mountainous city in the hot-summer and cold-winter zone of China, to examine the energy performance of white and sedum-tray garden roofs. The energy consumption of the three rooms was measured from September 2014 to September 2015 by monitoring the energy performance (temperature distributions of the roofs, evaporation, heat fluxes, and energy consumption) and indoor air temperature. The rooms had the same construction and appliances, except that one roof top was black, one was white, and one had a sedum-tray garden roof. This study references the International Performance Measurement and Verification Protocol (IPMVP) to calculate and compare the energy savings of the three kinds of roofs. The results indicate that the energy savings ratios of the rooms with the sedum-tray garden roof and with the white roof were 25.0% and 20.5%, respectively, as compared with the black-roofed room, in the summer; by contrast, the energy savings ratios were −9.9% and −2.7%, respectively, in the winter. Furthermore, Annual conditioning energy savings of white roof (3.9 kWh/m2) were 1.6 times the energy savings for the sedum-tray garden roof. It is evident that white roof is a preferable choice for office buildings in Chongqing. Additionally, The white roof had a reflectance of 0.58 after natural aging owing to the serious air pollution worsened its thermal performance, and the energy savings reduced by 0.033 kWh/m2·d. Evaporation was also identified to have a significant effect on the energy savings of the sedum-tray garden roof

    Using solar availability factors to adjust cool-wall energy savings for shading and reflection by neighboring buildings

    Get PDF
    The extent to which a solar-reflective “cool” wall can reduce a building's cooling load in summer or increase its heating load in winter scales with the wall's incident solar radiation, or solar availability. We assess how the solar availability at the wall of a central (modeled) building is affected by a neighboring wall across an urban canyon by calculating the central wall's solar availability factor (SAF), defined as the ratio of sunlight incident on the central wall in the presence of the neighboring wall to that incident in the absence of the neighboring wall. Cool-wall heating, ventilation, and air conditioning (HVAC) energy savings simulated for an isolated central building (no neighbors) can be multiplied by SAFs to account for interactions with neighboring walls. Monthly values of SAF were evaluated in 17 climates across the United States, including three in California, for north, east, south, and west central walls, over a wide range of canyon aspect ratio (height/width). Results for four representative aspect ratios—0.2, 1, 2, and 10—are presented. In Fresno, CA, monthly SAF ranges from 0.90 to 0.96 for central walls facing north, east, south, or west when the aspect ratio is 0.2 (two-story single-family homes across a street) and both the central and neighboring walls are conventional (albedo 0.25). Monthly SAFs decrease as aspect ratio rises, falling to 0.06–0.24 at an aspect ratio of 10 (adjacent 10-story buildings on the same side of the street). An example worked for a two-story single-family home in Fresno on the west side of a residential street yields SAFs of 0.47 (north), 0.92 (east), 0.50 (south), and 0.63 (west) to apply to the cool-wall annual HVAC energy savings computed for an isolated central building. Shading and reflection reduce the home's annual HVAC energy cost savings by 31%

    A New Era of Medicare Oversight

    Get PDF

    Probing Micro-quasars with TeV Neutrinos

    Get PDF
    The jets associated with Galactic micro-quasars are believed to be ejected by accreting stellar mass black-holes or neutron stars. We show that if the energy content of the jets in the transient sources is dominated by electron-proton plasma, then a several hour outburst of 1--100 TeV neutrinos produced by photo- meson interactions should precede the radio flares associated with major ejection events. Several neutrinos may be detected during a single outburst by a 1km^2 detector, thereby providing a powerful probe of micro-quasars jet physics.Comment: Accepted to PRL. More detailed discussion of particle acceleratio

    Shading and Smothering of Gamma Ray Bursts

    Get PDF
    The gamma ray burst (GRB) 980425 is distinctive in that it seems to be associated with supernova (SN) 1998bw, has no X-ray afterglow, and has a single peak light curve and a soft spectrum. The supernova is itself unusual in that its expansion velocity exceeds c/6. We suggest that many of these features can be accounted for with the hypothesis that we observe the GRB along a penumbral line of sight that contains mainly photons that have scattered off ejected baryons. The hypothesis suggests a baryon poor jet (BPJ) existing within a baryon rich outflow. The sharp distinction can be attributed to whether or not the magnetic field lines thread an event horizon. Such a configuration suggests that there will be some non-thermal acceleration of pick-up ex-neutrons within the BPJ. This scenario might produce observable spallation products and neutrinos.Comment: 7 pages, 2 figures, submitted to ApJ
    • 

    corecore