2,851 research outputs found

    Design of Ge/SiGe quantum-confined Stark effect electroabsorption heterostructures for CMOS compatible photonics

    Get PDF
    We describe a combined 6×6 k.p and one-band effective mass modelling tool to calculate absorption spectra in Ge–SiGe multiple quantum well (MQW) heterostructures. We find good agreement with experimentally measured absorption spectra of Ge–SiGe MQW structures described previously in the literature, proving its predictive capability, and the simulation tool is used for the analysis and design of electroabsorption modulators. We employ strain-engineering in Ge–SiGe MQW systems to design structures for modulation at 1310 nm and 1550 nm

    Tacrolimus analysis: A comparison of different methods and matrices

    Get PDF
    We determined the trough blood and plasma concentrations of tacrolimus from the day of transplantation through 30 days posttransplantation in four liver and four kidney transplant patients by three different methods. The first method involved a solid phase extraction of the blood or plasma using Sep-Pak columns (SPs) followed by quantitation of tacrolimus using an enzyme-linked immunosorbent assay (ELISA); the second method involved a liquid-liquid extraction using methylene chloride (MC) followed by quantitation of tacrolimus using the ELISA, and the third method involved a high-performance liquid chromatography (HPLC) fractionation of the extract obtained from the solid-phase extraction and quantitation of tacrolimus in the fractions by ELISA. The trough plasma tacrolimus concentrations ranged from 0.1 to 5.2 ng/ml. While the trough plasma concentrations of tacrolimus were similar and independent of the method of analysis in kidney transplant patients and in liver transplant patients with normal biochemical profile, in patients with liver dysfunction, tacrolimus plasma concentrations were higher when measured by SP-ELISA and MC-ELISA methods as compared to the HPLC-ELISA method. In plasma samples obtained from liver transplant patients with liver dysfunction, the presence of some metabolites that cross-reacted with the antibody used in the ELISA could be documented in the HPLC fraction corresponding to the metabolites. This indicates that while tacrolimus metabolites that cross-react significantly with the antibody used in the ELISA do not accumulate in kidney transplant patients, they can appear in the plasma of patients with liver dysfunction. The trough blood tacrolimus concentrations in patients were significantly higher than the corresponding plasma concentrations and ranged from 1.4 to 107 ng/ml. The trough blood tacrolimus concentrations were similar and independent of the method of analysis in kidney and liver transplant patients, suggesting unchanged tacrolimus to be the major component in the blood. The HPLC fractions corresponding to the metabolites of tacrolimus did not contain any components that cross-reacted with the antibody used. This study documents that the methods used in this study for the analysis of blood concentrations of tacrolimus appear to be specific for the parent tacrolimus and can be used in future pharmacokinetic and clinical studies. © 1995 Raven Press, Ltd., New York

    Improvements in Blast Fragmentation Models Using Digital Image Processing

    Get PDF
    One of the fundamental requirements for being able to optimise blasting is the ability to predict fragmentation. An accurate blast fragmentation model allows a mine to adjust the fragmentation size for different downstream processes (mill processing versus leach, for instance), and to make real time adjustments in blasting parameters to account for changes in rock mass characteristics (hardness, fracture density, fracture orientation, etc). A number of blast fragmentation models have been developed in the past 40 years such as the Kuz-Ram model [1]. Fragmentation models have a limited usefulness at the present time because: 1. The input parameters are not the most useful for the engineer to determine and data for these parameters are not available throughout the rock mass. 2. Even if the input parameters are known, the models still do not consistently predict the correct fragmentation. This is because the models capture some but not all of the important rock and blast phenomena. 3. The models do not allow for ‘tuning’ at a specific mine site. This paper describes studies that are being conducted to improve blast fragmentation models. The Split image processing software is used for these studies

    An architecture for systematic tracking of skills and competence level progression in computer science

    Full text link
    A typical Computer Science degree is three to five years long, consists of four to six subjects per semester, and two semesters per year. A student enrolled in such a degree is expected to learn both discipline-specific skills and transferable generic skills. These skills are to be taught in a progressive sequence through the duration of the degree. As the student progresses through the subjects and semesters of a degree, his skill portfolio and competence level for each skill is expected to grow. Effectively modeling these curriculum skills, mapping them to assessment tasks across subjects of a degree, and measuring the progression in learner competence level is, largely, still an unsolved problem. Previous work at this scale is limited. This systematic tracking of skills and competence is crucial for effective quality control and optimization of degree structures. Our main contribution is an architecture for a curriculum information management system to facilitate this systematic tracking of skill and competence level progression in a Computer Science context

    Interactive Digital Music: Enhancing Listener Engagement with Commercial Music

    Get PDF
    Listeners have long been inspired to interact with music and create new representations of popular releases. Vinyl offered many opportunities to reappropriate chart music, from scratching and tempo manipulation to mixing multiple songs together. More recently, artists could engage their audience to interact with their music by offering mix-stems online for experimentation and sharing. With the extended processing power of mobile devices, the opportunities for interactive music are dramatically increasing. This paper presents research that demonstrates a novel approach to interactive digital music. The research looks at the emergent format of the album app and extends existing paradigms of interactive music playback. The novel album app designed in this research presents a new opportunity for listeners to engage with recorded content by allowing them to explore alternative takes, renditions of a given song in multiple genres, and by allowing direct interaction with embedded mix-stems. The resultant audio remains true to the artist and producer’s studio vision; it is user-influenced, but machine-controlled. The research is conducted in collaboration with artist Daisy and The Dark and was funded by the UK Arts and Humanities Research Council

    Theory and design of quantum cascade lasers in (111) n-type Si/SiGe

    Get PDF
    Although most work towards the realization of group IV quantum cascade lasers (QCLs) has focused on valence band transitions, there are many desirable properties associated with the conduction band. We show that the commonly cited shortcomings of n-type Si/SiGe heterostructures can be overcome by moving to the (111) growth direction. Specifically, a large band offset and low effective mass are achievable and subband degeneracy is preserved. We predict net gain up to lattice temperatures of 90 K in a bound-to-continuum QCL with a double-metal waveguide, and show that a Ge interdiffusion length of at least 8 â„« across interfaces is tolerable

    FK506 measurement: Comparison of different analytical methods

    Get PDF
    In this study, we used solid-phase extraction with Sep-Pak and a liquid-liquid extraction with methylene chloride as two primary methods of extracting FK506 from plasma. The extracts were either analyzed directly by enzyme-linked immunosorbent assay (ELISA) or subjected to high-performance liquid chromatography (HPLC) separation and different fractions were analyzed by ELISA. Serial blood samples were obtained from four kidney transplant patients and four patients who underwent liver transplantation, from day 1 until day 30-35 posttransplantation. There was no significant difference in the FK506 plasma concentration as measured by all four methods in normal transplant patients. However, in liver transplant patients, the solid-phase extraction method gave higher FK506 concentrations than the methylene chloride extraction during the early postoperative period. The concentrations measured after methylene chloride extraction were higher than that after HPLC-ELISA. This higher FK506 concentration measured by direct ELISA could be attributed to possible cross-reacting metabolites that were present in the plasma of patients with abnormal liver functions. Once liver function returns to normal, all four methods give identical plasma concentrations for FK506. © 1993 Raven Press, Ltd., New York
    • …
    corecore