14 research outputs found

    Randomized Trial of Oxygen Saturation Targets during and after Resuscitation and Reversal of Ductal Flow in an Ovine Model of Meconium Aspiration and Pulmonary Hypertension

    No full text
    Neonatal resuscitation (NRP) guidelines suggest targeting 85–95% preductal SpO2 by 10 min after birth. Optimal oxygen saturation (SpO2) targets during resuscitation and in the post-resuscitation management of neonatal meconium aspiration syndrome (MAS) with persistent pulmonary hypertension (PPHN) remains uncertain. Our objective was to compare the time to reversal of ductal flow from fetal pattern (right-to-left), to left-to-right, and to evaluate pulmonary (QPA), carotid (QCA)and ductal (QDA) blood flows between standard (85–94%) and high (95–99%) SpO2 targets during and after resuscitation. Twelve lambs asphyxiated by endotracheal meconium instillation and cord occlusion to induce MAS and PPHN were resuscitated per NRP guidelines and were randomized to either standard (85–94%) or high (95–99%) SpO2 targets. Out of twelve lambs with MAS and PPHN, six each were randomized to standard and high SpO2 targets. Median [interquartile range] time to change in direction of blood flow across the ductus arteriosus from right-to-left, to left-to-right was significantly shorter with high SpO2 target (7.4 (4.4–10.8) min) compared to standard SpO2 target (31.5 (21–66.2) min, p = 0.03). QPA was significantly higher during the first 10 min after birth with higher SpO2 target. At 60 min after birth, the QPA, QCA and QDA were not different between the groups. To conclude, targeting SpO2 of 95–99% during and after resuscitation may hasten reversal of ductal flow in lambs with MAS and PPHN and transiently increase QPA but no differences were observed at 60 min. Clinical studies comparing low and high SpO2 targets assessing hemodynamics and neurodevelopmental outcomes are warranted

    Role of Volume Replacement during Neonatal Resuscitation in the Delivery Room

    No full text
    Volume expanders are indicated in the delivery room when an asphyxiated neonate is not responding to the steps of neonatal resuscitation and has signs of shock or a history of acute blood loss. Fetal blood loss (e.g., feto-maternal hemorrhage) may contribute to perinatal asphyxia. Cord compression or a tight nuchal cord can selectively occlude a thin-walled umbilical vein, resulting in feto-placental transfusion and neonatal hypovolemia. For severe bradycardia or cardiac arrest secondary to fetal blood loss, Neonatal Resuscitation Program (NRP) recommends intravenous volume expanders (crystalloids such as normal saline or packed red blood cells) infused over 5 to 10 min. Failure to recognize hypovolemia and subsequent delay in volume replacement may result in unsuccessful resuscitation due to lack of adequate cardiac preload. However, excess volume load in the presence of myocardial dysfunction from hypoxic–ischemic injury may precipitate pulmonary edema and intraventricular hemorrhage (especially in preterm infants). Emergent circumstances and ethical concerns preclude the performance of prospective clinical studies evaluating volume replacement during neonatal resuscitation. Translational studies, observational data from registries and clinical trials are needed to investigate and understand the role of volume replacement in the delivery room in term and preterm neonates. This article is a narrative review of the causes and consequences of acute fetal blood loss and available evidence on volume replacement during neonatal resuscitation of asphyxiated neonates

    Randomized trial of oxygen weaning strategies following chest compressions during neonatal resuscitation.

    No full text
    BackgroundThe Neonatal Resuscitation Program (NRP) recommends using 100% O2 during chest compressions and adjusting FiO2 based on SpO2 after return of spontaneous circulation (ROSC). The optimal strategy for adjusting FiO2 is not known.MethodsTwenty-five near-term lambs asphyxiated by umbilical cord occlusion to cardiac arrest were resuscitated per NRP. Following ROSC, lambs were randomized to gradual decrease versus abrupt wean to 21% O2 followed by FiO2 titration to achieve NRP SpO2 targets. Carotid blood flow and blood gases were monitored.ResultsThree minutes after ROSC, PaO2 was 229 ± 32 mmHg in gradual wean group compared to 57 ± 13 following abrupt wean to 21% O2 (p < 0.001). PaO2 remained high in the gradual wean group at 10 min after ROSC (110 ± 10 vs. 67 ± 12, p < 0.01) despite similar FiO2 (~0.3) in both groups. Cerebral O2 delivery (C-DO2) was higher above physiological range following ROSC with gradual wean (p < 0.05). Lower blood oxidized/reduced glutathione ratio (suggesting less oxidative stress) was observed with abrupt wean.ConclusionWeaning FiO2 abruptly to 0.21 with adjustment based on SpO2 prevents surge in PaO2 and C-DO2 and minimizes oxidative stress compared to gradual weaning from 100% O2 following ROSC. Clinical trials with neurodevelopmental outcomes comparing post-ROSC FiO2 weaning strategies are warranted.ImpactIn a lamb model of perinatal asphyxial cardiac arrest, abrupt weaning of inspired oxygen to 21% prevents excessive oxygen delivery to the brain and oxidative stress compared to gradual weaning from 100% oxygen following return of spontaneous circulation. Clinical studies assessing neurodevelopmental outcomes comparing abrupt and gradual weaning of inspired oxygen after recovery from neonatal asphyxial arrest are warranted
    corecore