16 research outputs found

    A new virtual ring-based system matrix generator for iterative image reconstruction in high resolution small volume PET systems

    Full text link
    © 2015 Institute of Physics and Engineering in Medicine. A common approach to improving the spatial resolution of small animal PET scanners is to reduce the size of scintillation crystals and/or employ high resolution pixellated semiconductor detectors. The large number of detector elements results in the system matrix - an essential part of statistical iterative reconstruction algorithms - becoming impractically large. In this paper, we propose a methodology for system matrix modelling which utilises a virtual single-layer detector ring to greatly reduce the size of the system matrix without sacrificing precision. Two methods for populating the system matrix are compared; the first utilises a geometrically-derived system matrix based on Siddon's ray tracer method with the addition of an accurate detector response function, while the second uses Monte Carlo simulation to populate the system matrix. The effectiveness of both variations of the proposed technique is demonstrated via simulations of PETiPIX, an ultra high spatial resolution small animal PET scanner featuring high-resolution DoI capabilities, which has previously been simulated and characterised using classical image reconstruction methods. Compression factors of and are achieved using this methodology for the system matrices produced using the geometric and Monte Carlo-based approaches, respectively, requiring a total of 0.5-1.2 GB of memory-resident storage. Images reconstructed from Monte Carlo simulations of various point source and phantom models, produced using system matrices generated via both geometric and simulation methods, are used to evaluate the quality of the resulting system matrix in terms of achievable spatial resolution and the CRC, CoV and CW-SSIM index image quality metrics. The Monte Carlo-based system matrix is shown to provide the best image quality at the cost of substantial one-off computational effort and a lower (but still practical) compression factor. Finally, a straightforward extension of the virtual ring method to a three dimensional virtual cylinder is demonstrated using a 3D DoI PET scanner

    BrachyView, a novel in-body imaging system for HDR prostate brachytherapy: Experimental evaluation

    Full text link
    © 2015 American Association of Physicists in Medicine. Purpose: This paper presents initial experimental results from a prototype of high dose rate (HDR) BrachyView, a novel in-body source tracking system for HDR brachytherapy based on a multipinhole tungsten collimator and a high resolution pixellated silicon detector array. The probe and its associated position estimation algorithms are validated and a comprehensive evaluation of the accuracy of its position estimation capabilities is presented. Methods: The HDR brachytherapy source is moved through a sequence of positions in a prostate phantom, for various displacements in x, y, and z. For each position, multiple image acquisitions are performed, and source positions are reconstructed. Error estimates in each dimension are calculated at each source position and combined to calculate overall positioning errors. Gafchromic film is used to validate the accuracy of source placement within the phantom. Results: More than 90% of evaluated source positions were estimated with an error of less than one millimeter, with the worst-case error being 1.3 mm. Experimental results were in close agreement with previously published Monte Carlo simulation results. Conclusions: The prototype of HDR BrachyView demonstrates a satisfactory level of accuracy in its source position estimation, and additional improvements are achievable with further refinement of HDR BrachyView's image processing algorithms

    Radiation dose enhancement at tissue-tungsten interfaces in HDR brachytherapy

    Full text link
    © 2014 Institute of Physics and Engineering in Medicine. HDR BrachyView is a novel in-body dosimetric imaging system for real-time monitoring and verification of the source position in high dose rate (HDR) prostate brachytherapy treatment. It is based on a high-resolution pixelated detector array with a semi-cylindrical multi-pinhole tungsten collimator and is designed to fit inside a compact rectal probe, and is able to resolve the 3D position of the source with a maximum error of 1.5 mm. This paper presents an evaluation of the additional dose that will be delivered to the patient as a result of backscatter radiation from the collimator. Monte Carlo simulations of planar and cylindrical collimators embedded in a tissue-equivalent phantom were performed using Geant4, with an 192Ir source placed at two different source-collimator distances. The planar configuration was replicated experimentally to validate the simulations, with a MOSkin dosimetry probe used to measure dose at three distances from the collimator. For the cylindrical collimator simulation, backscatter dose enhancement was calculated as a function of axial and azimuthal displacement, and dose distribution maps were generated at three distances from the collimator surface. Although significant backscatter dose enhancement was observed for both geometries immediately adjacent to the collimator, simulations and experiments indicate that backscatter dose is negligible at distances beyond 1 mm from the collimator. Since HDR BrachyView is enclosed within a 1 mm thick tissue-equivalent plastic shell, all backscatter radiation resulting from its use will therefore be absorbed before reaching the rectal wall or other tissues. dosimetry, brachytherapy, HD

    3D Radiation Detectors: Charge Collection Characterisation and Applicability of Technology for Microdosimetry

    No full text
    A study of charge collection in SINTEF 3D active edge silicon detectors was carried out at ANSTO using Ion Beam Induced Charge (IBIC) technique. An IBIC study has shown that several different geometries of 3D detectors have full depletion under low applied bias. The effect of fast neutron and gamma radiation on their charge collection efficiency was also investigated. A 3D active edge silicon detector technology has demonstrated extremely promising performance for application of the 3D Sensitive Volumes (SVs) fabrication methods to SOI microdosimetry.© 2014, IEEE

    A novel silicon microdosimeter using 3D sensitive volumes: modeling the response in neutron fields typical of aviation

    No full text
    A 4th generation silicon microdosimeter has been designed by the Centre for Medical Radiation Physics (CMRP) at the University of Wollongong using three dimensional (3D) Sensitive Volumes (SVs). This new microdosimeter design has the advantage of well-defined 3D SVs as well as the elimination of lateral charge diffusion by removal of silicon laterally adjacent to the 3D SVs. The gaps between the sensitive volumes are to be backfilled with PolyMethyl MethAcrylate (PMMA) to produce a surrounding tissue equivalent medium. The advantage of this design avoids the generation of secondary particles from inactive silicon lateral to SVs. The response of the microdosimeter to the neutron field from 252Cf, Pu-Be sources and an avionic radiation environment were simulated using the Geant4 Monte Carlo toolkit for design optimisation. The simulated energy deposition in the SVs from the neutron fields and microdosimetric spectra is presented. The simulation study shows a significant reduction in silicon nuclear recoil contribution to the energy deposition for the novel microdosimeter design. The reduction of silicon recoil events from outside of the SV's will consequently reduce the uncertainty in the calculated dose equivalent. The simulations have demonstrated that a 3D silicon microdosimeter surrounded by PMMA can produce microdosimetric spectra similar to those of a tissue equivalent microdosimeter.© 2014, IEEE

    Design and development of PETiPIX: An ultra high spatial resolution small animal PET scanner

    Full text link
    PETiPIX is an ultra high spatial resolution small animal PET scanner designed for scanning of mouse brains. It utilises four state of the art pixellated silicon detectors, Timepix, in an edge-on configuration to provide a field of view (FoV) 15 mm in diameter. Each Timepix detector consists of 256×256 pixels, with pixel dimensions of 55μm×55μm× 300μm. Monte Carlo simulations have been carried to evaluate the performance of the proposed scanner. The simulated scanner achieved an overall spatial resolution of 0.29 mm (measuring at full width at half maximum (FWHM)) with a sensitivity of 0.01%. Two separate phantom studies (hot phantom and cold Jaszczk phantom) have been performed and their results demonstrate that PETiPIX is capable of achieving a high spatial resolution across its full FoV. Preliminary experiments recording recoil electrons tracks from Compton scattering events agree with the simulation results. Experiments involving two synchronised Timepix modules with a 68Ga point source placed in the centre of the FoV demonstrated the capability of PETiPIX prototype to record true coincidence events. © 2013 IEEE

    A feasibility study of PETiPIX: An ultra high resolution small animal PET scanner

    Full text link
    PETiPIX is an ultra high spatial resolution positron emission tomography (PET) scanner designed for imaging mice brains. Four Timepix pixellated silicon detector modules are placed in an edge-on configuration to form a scanner with a field of view (FoV) 15 mm in diameter. Each detector module consists of 256 × 256 pixels with dimensions of 55 × 55 × 300 μm 3. Monte Carlo simulations using GEANT4 Application for Tomographic Emission (GATE) were performed to evaluate the feasibility of the PETiPIX design, including estimation of system sensitivity, angular dependence, spatial resolution (point source, hot and cold phantom studies) and evaluation of potential detector shield designs. Initial experimental work also established that scattered photons and recoil electrons could be detected using a single edge-on Timepix detector with a positron source. Simulation results estimate a spatial resolution of 0.26 mm full width at half maximum (FWHM) at the centre of FoV and 0.29 mm FWHM overall spatial resolution with sensitivity of 0.01%, and indicate that a 1.5 mm thick tungsten shield parallel to the detectors will absorb the majority of non-coplanar annihilation photons, significantly reducing the rates of randoms. Results from the simulated phantom studies demonstrate that PETiPIX is a promising design for studies demanding high resolution images of mice brains.© 2013 IOP Publishing Ltd and Sissa Medialab srl

    Evaluation of silicon detectors with integrated JFET for biomedical applications

    Get PDF
    This paper presents initial results from electrical, spectroscopic and ion beam induced charge (IBIC) characterisation of a novel silicon PIN detector, featuring an on-chip n-channel JFET and matched feedback capacitor integrated on its p-side (frontside). This structure reduces electronic noise by minimising stray capacitance and enables highly efficient optical coupling between the detector back-side and scintillator, providing a fill factor of close to 100%. The detector is specifically designed for use in high resolution gamma cameras, where a pixellated scintillator crystal is directly coupled to an array of silicon photodetectors. The on-chip JFET is matched with the photodiode capacitance and forms the input stage of an external charge sensitive preamplifier (CSA). The integrated monolithic feedback capacitor eliminates the need for an external feedback capacitor in the external electronic readout circuit, improving the system performance by eliminating uncontrolled parasitic capacitances. An optimised noise figure of 152 electrons RMS was obtained with a shaping time of 2 μs and a total detector capacitance of 2pF. The energy resolution obtained at room temperature (21 ° C) at 27 keV (direct interaction of I-125 gamma rays) was 5.09%, measured at full width at half maximum (FWHM). The effectiveness of the guard ring in minimising the detector leakage current and its influence on the total charge collection volume is clearly demonstrated by the IBIC images. © 2006 IEEE
    corecore