53 research outputs found

    Les protocoles opératoires en endodontie d'urgence chez l'adulte

    No full text
    MONTPELLIER-BU MĂ©decine UPM (341722108) / SudocMONTPELLIER-BU Odontologie (341722110) / SudocMONTPELLIER-BU MĂ©decine (341722104) / SudocPARIS-BIUM (751062103) / SudocSudocFranceF

    Statistical mechanics of pump-probe absorption in liquids

    No full text
    Basic theory of pump-probe absorption in liquids is presented. Statistical expressions relating the measured signal to the relevant dynamical variables are given for various experimental arrangements and for different polarizations. The basic literature is reviewed next. Only pump-probe spectroscopy is examined systematically; other configurations are only occasionally mentioned

    Autoassociation de la pyrochlorophylle a en solution

    No full text
    La comparaison des spectres infrarouges des chlorophylle pyrochlorophylle, phĂ©ophytine et pyrophĂ©ophytine a permet de confirmer que l’autoassociation des deux premiĂšres rĂ©sulte bien d’une interaction entre le magnĂ©sium d'une molĂ©cule de pigment et l’oxygĂšne de la fonction cĂ©tone d’une autre

    Une source de lumiÚre pour le dosage isotopique de l'uranium par spectrométrie d'émission

    No full text
    A process is described for producing and exciting electrodeless uranium tetrachloride or tetraiodide lamps emitting the optical spectrum of uranium with an intensity, a purity, and a stability sufficient to allow the isotopic analysis to be carried out with the " HypĂ©ac " interference spectrometer. The process of fabrication is simple and rapid, and can be used for routine analyses.On dĂ©crit un procĂ©dĂ© de fabrication et d'excitation de lampes sans Ă©lectrodes au tĂ©trachlorure ou au tĂ©traiodure d'uranium qui Ă©mettent le spectre optique de l'uranium avec une intensitĂ©, une puretĂ© et une stabilitĂ© suffisantes pour permettre l'analyse isotopique avec le spectromĂštre interfĂ©rentiel « HypĂ©ac ». Le procĂ©dĂ© de fabrication est simple et rapide et peut ĂȘtre utilisĂ© pour des analyses de routine

    Chapitre 5. Le matériel archéologique

    No full text
    André-Leicknam Béatrice, Salles Jean-Francois. Chapitre 5. Le matériel archéologique. In: La Nécropole de Janussan (Bahrain) Sous la direction de Pierre Lombard et Jean-François Salles. Lyon : Maison de l'Orient et de la Méditerranée Jean Pouilloux, 1984. pp. 103-136. (Travaux de la Maison de l'Orient, 6

    XFEL experiments: jitter of pump–probe time delays and pulse intensities

    No full text
    International audienceJitter of XFEL signals due to fluctuations in shot-to-shot time delays and intensities are explored in the frame of a statistical theory of X-ray diffraction from liquids. Deformed signals are calculated at different levels of pump–probe jitter. A new method is proposed to eliminate these distortions

    Laser spectroscopic visualization of hydrogen bond motions in liquid water

    No full text
    International audienceUltrafast pump-probe experiments are described permitting a visualization of molecular motions in diluted HDO/D2O solutions. The experiments were realized in the mid-infrared spectral region with a time resolution of 150 fs. They were interpreted by a careful theoretical analysis, based on the correlation function approach of statistical mechanics. Combining experiment and theory, stretching motions of the OH?O bonds as well as HDO rotations were 'filmed' in real time. It was found that molecular rotations are the principal agent of hydrogen bond breaking and making in water. Recent literatures covering the subject, including molecular dynamics simulations, are reviewed in detail. Cop. 2004 Elsevier B.V. All rights reserved

    Étude comparĂ©e de quelques vibrateurs XH et XD frĂ©quences et intensitĂ©s des bandes d’adsorption infrarouge

    No full text
    Les frĂ©quences et les intensitĂ©s des vibrations de valence X — H et X — D des halogĂ©noformes, du phĂ©nol et du pyrrole lĂ©gers et deutĂ©riĂ©s sont mesurĂ©s. Pour toutes ces molĂ©cules les valeurs des rapports ÎœH2/ÎœD2 et AH/AD sont voisins de 2, le couplage des vibrations de valence X — H ou X — D avec les autres vibrations est donc trĂšs lĂąche

    Interactions de phtalocyanines, de porphyrines de magnĂ©sium et de la chlorophylle "a" avec des molĂ©cules polaires. I — Complexes pyridine-tĂ©traphĂ©nylporphyrine de Mg et pyridine-mĂ©tallophtalocyanines Ă  l'Ă©tat solide

    No full text
    Pour parvenir Ă  une meilleure connaissance des interactions molĂ©culaires qui se produisent dans le systĂšme photosynthĂ©tique entre les pigments et le milieu environnant, on recense les propriĂ©tĂ©s acceptrices d'Ă©lectrons de porphyrines et de la phtalocyanine de magnĂ©sium (servant de modĂšle de la chlorophylle) vis-Ă -vis d'un donneur comme la pyridine. La thermogravimĂ©trie et la spectromĂ©trie infrarouge permettent de dĂ©terminer la stƓchiomĂ©trie des diffĂ©rents complexes Ă  l'Ă©tat solide et de prĂ©ciser la nature des liaisons intermolĂ©culaires. Des molĂ©cules de donneur sont simplement physisorbĂ©es, alors que d'autres se lient chimiquement avec le pigment pour donner des complexes de compositions bien dĂ©finies. Il y a deux sortes de complexes de stabilitĂ© thermique trĂšs diffĂ©rente ; le plus stable est le seul Ă  prĂ©senter une absorption caractĂ©ristique d'une liaison dative intermolĂ©culaire Mg . . . N, qui est sensible Ă  la substitution isotopique du magnĂ©sium ; il n'y a qu'une liaison de ce type par molĂ©cule de pigment. Les rĂ©sultats sont comparĂ©s avec ceux des phtalocyanines de fer et de zinc
    • 

    corecore