80 research outputs found

    High refractive index of melanin in shiny occipital feathers of a bird of paradise

    Get PDF
    Male Lawes's Parotia, a bird of paradise, use the highly directional reflection of the structurally colored, brilliant-silvery occipital feathers in their courtship display. As in other birds, the structural coloration is produced by ordered melanin pigmentation. The barbules of the Parotia's occipital feathers, with thickness ~3 µm, contain 6–7 layers of densely packed melanin rodlets (diameter ~0.25 µm, length ~2 µm). The effectively ~0.2 µm thick melanin layers separated by ~0.2 µm thick keratin layers create a multilayer interference reflector. Reflectance measurements yielded peak wavelengths in the near-infrared at ~1.3 µm, i.e., far outside the visible wavelength range. With the Jamin-Lebedeff interference microscopy method recently developed for pigmented media, we here determined the refractive index of the intact barbules. We thus derived the wavelength dependence of the refractive index of the barbules' melanin to be 1.7–1.8 in the visible wavelength range. Implementing the anatomical and refractive index data in an optical multilayer model, we calculated the barbules' reflectance, transmittance and absorptance spectra, thereby confirming measured spectra

    Stent placement for renal arterial stenosis: where do we stand? A meta-analysis

    Get PDF
    PURPOSE: To perform a meta-analysis of renal arterial stent placement in comparison with renal percutaneous transluminal angioplasty (PTA) in patients with renal arterial stenosis. MATERIALS AND METHODS: Studies dealing with renal arterial stent placement (14 articles; 678 patients) and renal PTA (10 articles; 644 patients) published up to August 1998 were selected. A random-effects model was used to pool the data. RESULTS: Renal arterial stent placement proved highly successful, with an initial adequate performance in 98% and major complications in 11%. The overall cure rate for hypertension was 20%, whereas hypertension was improved in 49%. Renal function improved in 30% and stabilized in 38% of patients. The restenosis rate at follow-up of 6-29 months was 17%. Stent placement had a higher technical success rate and a lower restenosis rate than did renal PTA (98% vs 77% and 17% vs 26%, respectively; P <.001). The complication rate was not different between the two treatments. The cure rate for hypertension was higher and the improvement rate for renal function was lower after stent placement than after renal PTA (20% vs 10% and 30% vs 38%, respectively; P <.001). CONCLUSION: Renal arterial stent placement is technically superior and clinically comparable to renal PTA alone

    Stent placement for renal artery

    No full text
    • …
    corecore