55 research outputs found

    A Basic Study on the Development of Ear-type Smart Monitor for Healthcare

    Get PDF
    13301甲第4039号博士(工学)金沢大学博士論文要旨Abstrac

    Development of an LCD-Based Visual Field System

    Get PDF
    Background: The present study investigated the diagnostic effectiveness of an LCD-based visual field testing system (LVF) in comparison with the standard automated perimetry Humphrey Field Analyzer II-750i (HFA). Methods: A randomized controlled crossover study was conducted with 202 normal and 128 glaucomatous eyes using both LVF and HFA. The visual field testing systems were compared in terms of mean deviation (MD), pattern standard deviation (PSD), and area under the receiver operating characteristics curve (AUC) of MD and PSD differentiating the normal and glaucomatous eyes. Results: Significant correlations were found between MD measurements from LVF and those from HFA for normal eyes (r = 0.342) and glaucomatous eyes (r = 0.796); slightly higher significant correlations were identified between PSD measurements from LVF and those from HFA for normal eyes (r = 0.363) and glaucomatous eyes (r = 0.828). Furthermore, high AUCs of MD were found as 0.786 for LVF and 0.868 for HFA and AUCs of PSD as 0.913 for LVF and 0.932 for HFA. Conclusion: The comparison results of the present study support the competence of LVF compared with HFA in visual field testing for early detection of glaucoma.11Ysciescopuskc

    A Basic Study on the Development of Ear-type Smart Monitor for Healthcare

    Get PDF
    13301甲第4039号博士(工学)金沢大学博士論文本文Ful

    Side-scattered finger-photoplethysmography: experimental investigations toward practical noninvasive measurement of blood glucose

    Get PDF
    The aim of this study was to discover a simple/convenient geometrical arrangement of radiation sources and detector to acquire finger-photoplethysmograms (PPGs) with wavelength regions of blood glucose (BGL) absorption, toward practical noninvasive BGL measurement. First, we compared PPGs with three wavelengths: 808 nm (without water absorption), 1160 nm (with weak water absorption), and 1600 nm (with nearly peak BGL absorption and strong water absorption), while the source-detector spacing was successively increased circumferentially around a fingertip. In 10 healthy subjects, we observed clear cardiac-related pulsatile components of PPG signals at 808 and 1160 nm in any incident positions with more than 15 dB of signal-to-noise ratio (S/N), but reliable PPG detections at 1600 nm with more than 10 dB of S/N was only possible when the source-detector distance was less than 3mm around the fingertip circumference. Second, with this arrangement, an experiment was performed using six wavelengths to cover glucose absorption bands (from 1550 to 1749 nm), obtaining pulsatile PPG signals with more or less 15 dB of S/N. Through the present experiments, this orthogonal arrangement of the source and detector to detect forward-and side-scattered radiation through the tissue is appropriate for PPG measurements with wavelength regions where there is potential for BGL measurement

    Comparison between red, green and blue light reflection photoplethysmography for heart rate monitoring during motion

    Get PDF
    Reflection photoplethysmography (PPG) using 530 nm (green) wavelength light has the potential to be a superior method for monitoring heart rate (HR) during normal daily life due to its relative freedom from artifacts. However, little is known about the accuracy of pulse rate (PR) measured by 530 nm light PPG during motion. Therefore, we compared the HR measured by electrocadiography (ECG) as a reference with PR measured by 530, 645 (red), and 470 nm (blue) wavelength light PPG during baseline and while performing hand waving in 12 participants. In addition, we examined the change of signal-to-noise ratio (SNR) by motion for each of the three wavelengths used for the PPG. The results showed that the limit of agreement in Bland-Altman plots between the HR measured by ECG and PR measured by 530 nm light PPG (±0.61 bpm) was smaller than that achieved when using 645 and 470 nm light PPG (±3.20 bpm and ±2.23 bpm, respectively). The ΔSNR (the difference between baseline and task values) of 530 and 470nm light PPG was significantly smaller than ΔSNR for red light PPG. In conclusion, 530 nm light PPG could be a more suitable method than 645 and 470nm light PPG for monitoring HR in normal daily life. © 2013 IEEE

    Potential for health screening using long-term cardiovascular parameters measured by finger volume-oscillometry: Pilot comparative evaluation in regular and sleep-deprived activities

    Get PDF
    We explored the potential of health screening based on the long-term measurement of cardiovascular parameters using the finger volume-oscillometric technique. An automated instrument made simultaneous measurements of key cardiovascular parameters, including blood pressure, pulse pressure, heart rate, normalized pulse volume as an index of α-adrenalin-mediated sympathetic activity, and finger arterial elasticity. These were derived from finger photo-plethysmographic signals during application of cuff pressure. To assess the feasibility of achieving a screening function, measurements were made in ten healthy volunteers during 10 days of day-to-day living (normal condition), and carried out several times at a fixed time every day. During successive 10-day measurements, a 30-hour period of total sleep deprivation was introduced as a physiological challenge (abnormal condition). A linear discriminant analysis of the data was conducted to determine whether these two conditions could be discriminated. Periodic data collection was performed rapidly and easily, and the %-correct classifications of normal and abnormal conditions were 78.2% and 77.5%, respectively. This ability of the method to discriminate between regular and sleep-deprived activities demonstrates its potential for healthcare screening during day-to-day living. Further investigations using larger age and gender groups of subjects including patients with cardiovascular diseases under real-life situations are required. © 2013 IEEE

    Fibrin Glue Reduces the Duration of Lymphatic Drainage after Lumpectomy and Level II or III Axillary Lymph Node Dissection for Breast Cancer: A Prospective Randomized Trial

    Get PDF
    This randomized prospective study investigated the effect of fibrin glue use on drainage duration and overall drain output after lumpectomy and axillary dissection in breast cancer patients. A total of 100 patients undergoing breast lumpectomy and axillary dissection were randomized to a fibrin glue group (N=50; glue sprayed onto the axillary dissection site) or a control group (N=50). Outcome measures were drainage duration, overall drain output, and incidence of seroma. Overall, the fibrin glue and control groups were similar in terms of drainage duration, overall drain output, and incidence of seroma. However, subgroup analysis showed that fibrin glue use resulted in a shorter drainage duration (3.5 vs. 4.7 days; p=0.0006) and overall drain output (196 vs. 278 mL; p=0.0255) in patients undergoing level II or III axillary dissection. Fibrin glue use reduced drainage duration and overall drain output in breast cancer patients undergoing a lumpectomy and level II or III axillary dissection

    Validation of normalized pulse volume in the outer ear as a simple measure of sympathetic activity using warm and cold pressor tests: Towards applications in ambulatory monitoring

    Get PDF
    Normalized pulse volume (NPV) derived from the ear has the potential to be a practical index for monitoring daily life stress. However, ear NPV has not yet been validated. Therefore, we compared NPV derived from an index finger using transmission photoplethysmography as a reference, with NPV derived from a middle finger and four sites of the ear using reflection photoplethysmography during baseline and while performing cold and warm water immersion in ten young and six middle-aged subjects. The results showed that logarithmically-transformed NPV (lnNPV) during cold water immersion as compared with baseline values was significantly lower, only at the index finger, the middle finger and the bottom of the ear-canal. Furthermore, lnNPV reactivities (ΔlnNPV; the difference between baseline and test values) from an index finger were significantly related to ΔlnNPV from the middle finger and the bottom of the ear-canal (young: r = 0.90 and 0.62, middle-aged: r = 0.80 and 0.58, respectively). In conclusion, these findings show that reflection and transmission photoplethysmography are comparable methods to derive NPV in accordance with our theoretical prediction. NPV derived from the bottom of the ear-canal is a valid approach, which could be useful for evaluating daily life stress. © 2013 Institute of Physics and Engineering in Medicine

    Development of a novel tympanic temperature monitoring system for GT car racing athletes

    Get PDF
    Motor racing athletes, especially Grand Touring (GT) car racing drivers in the closed-cockpit category, can face lifethreatening situations caused by heat stroke. In this paper, a novel continuous tympanic temperature monitoring system, that could help to reduce this risk, is presented. The system consists of an earpiece containing an infrared-radiation-type tympanic thermometer and a micro-speaker. We validated the reliability of the system for tympanic temperature monitoring in 10 healthy volunteers (21.8 ± 1.0 S.D. years) using a temperature-controlled water bath. In addition, we evaluated the usefulness of the system with 2 professional drivers under real racing conditions in the 2010 SUPER GT International Series. The results showed strong correlation between the infrared-radiation tympanic temperature obtained by the present system and both the direct tympanic temperature (r = 0.994, n = 1119, P < 0.001) and the sublingual temperature (r = 0.972, n = 1119, P < 0.001) as a reference temperature. The mean difference between these temperatures was +0.09°C, and -0.08°C, and 95 % confidence interval (equal to 1.96 S.D.) was 0.21°C, and 0.44°C, respectively. In the field test, involving real competitive racing under severe conditions on a racing circuit, the system functioned well. These results suggest that our novel system has an acceptable performance in a race setting as a reliable tympanic temperature monitor and could help to improve safety of motor sports. © 2013 Springer-Verlag

    Association of lipid profile with obesity among breast cancer survivors: a cross-sectional study

    Get PDF
    Background The role of lipid metabolism in obesity and cancer manifestations cannot be underestimated, but whether alterations in lipid metabolism can manipulate the vasculature to promote obesity among breast cancer (BC) survivors is yet to be clearly understood. This study quantified plasma lipid and particle sizes using high-throughput proton (1H) nuclear magnetic resonance (NMR) and tested their associations with obesity among breast cancer (BC) survivors. Methods A total of 348 (225 premenopausal and 123 postmenopausal) BC survivors enrolled from five hospitals in Korea were included. We assessed thirty-four plasma lipid biomarkers using 1H NMR, and obesity status was defined as a body mass index (BMI) of 25 kg/m2 or greater. Generalized linear and logistic regression models were applied to estimate the least-square means of BMI (kg/m2) and odds ratio (OR)s of obesity, respectively, and the corresponding 95% confidence interval (CI)s across plasma lipid levels. Results Mean (SD) values of BMI was 23.3 (3.2) kg/m2 and 90 (25.9%) had BMI of ≥ 25 kg/m2. BMI levels increased with increasing total triglycerides (TG), TG in lipoproteins and very-low-density lipoprotein (VLDL) subfractions. However, BMI levels decreased with increasing tertiles of high-density lipoprotein (HDL)-cholesterol (C) and HDL particle size (HDL-p). Similar associations were observed in the logistic regression models. The increasing and decreasing BMI trends with TG and HDL profiles respectively were predominantly limited to premenopausal BC survivors. Conclusions Increasing levels of plasma total TG and TG in lipoproteins were associated with increasing levels of BMI among premenopausal BC survivors. High HDL-C levels and large HDL-p were inversely associated with obesity among premenopausal BC survivors. Due to the cross-sectional design of this study, longitudinal studies are necessary to examine the association between obesity and lipid profile among BC survivors.This research was supported by the Brain Pool Program supported through the National Research Foundation of Korea, funded by the Ministry of Science and ICT (2020H1D3A1A04081265). Also, the data collection and recruitment of this work were supported by the National Research Foundation of Korea Grant funded by the Korean government (MSIT) (No. 2014R1A2A2A01007794, 2019R1F1A1061017 and 2021R1F1A1062476). The funders had no role in the study design, data collection and analysis, or decision to prepare and publish the manuscript