13 research outputs found

    Biosensing comparison between different geometries based on vertical submicron-structrures made of SU-8 resist

    Get PDF
    Previous work of the research group [1-4] demonstrated the viability of using periodic lattices of micro and nanopillars, called Bio-photonic sensing Cells (BICELLs), as an optical biosensor vertically characterized by visible spectrometry. Also we have studied theoretically [5] the performance of the BICELLs by 2D and 3D simulation in orde r to optimize the biosensing response. In this work we present the fabrication and biosensing comparison of different geometrical parameters on periodic lattices of pillars in order to discuss theoretical conclusions with these results. In this way, we have explored the biosensing response of other patter ns such as crosses, stars, cylinders, concentrical cylinders (Figure 1). Also we introduced a novel method to test the BICELLs in a cost-effective way by using an ultra-thin film of SU-8 spin-coated onto the patterns to reproduce the effect of a biofilm attached to the biosensor surface. Finally we have tested the biosensing response of the different geometries by the well-known Bovine Serum Albumin (BSA) immunoassay and compared with the theoretical simulation

    Characterization of the Performance of Optical Label-Free Biosensors

    Full text link
    The field of optical label free biosensors has become a topic of interest during past years, with devices based on the detection of angular or wavelength shift of optical modes [1]. Common parameters to characterize their performance are the Limit of Detection (LOD, defined as the minimum change of refractive index upon the sensing surface that the device is able to detect, and also BioLOD, which represents the minimum amount of target analyte accurately resolved by the system; with units of concentration (common un its are p pm, ng/ml, or nM). LOD gives a first value to compare different biosensors, and is obtained both theoretically (using photonic calculation tools), and experimentally,covering the sensing area with fluids of different refractive indexes

    Optimization of Dengue immunoassay by label-free interferometric optical detection method

    Get PDF
    In this communication we report a direct immunoassay for detecting dengue virus by means of a label-free interferometric optical detection method. We also demonstrate how we can optimize this sensing response by adding a blocking step able to significantly enhance the optical sensing response. The blocking reagent used for this optimization is a dry milk diluted in phosphate buffered saline. The recognition curve of dengue virus over the proposed surface sensor demonstrates the capacity of this method to be applied in Point of Care technology

    Microfabrication processes for microfluidic devices on a single laser Workstation: direct writing lithography on SU-8, laser ablation on polymers and mask manufacturing

    Full text link
    We demonstrate the capability of a laser micromachining workstation for cost-effective manufacturing of a variety of microfluidic devices, including SU-8 microchannels on silicon wafers and 3D complex structures made on polyimide Kapton® or poly carbonate (PC). The workstation combines a KrF excimer laser at 248 nm and a Nd3+:YVO4 DPSS with a frequency tripled at 355 nm with a lens magnification 10X, both lasers working at a pulsed regime with nanoseconds (ns) pulse duration. Workstation also includes a high-resolution motorized XYZ-tilt axis (~ 1 um / axis) and a Through The Lens (TTL) imaging system for a high accurate positioning over a 120 x 120 mm working area. We have surveyed different fabrication techniques: direct writing lithography,mask manufacturing for contact lithography and polymer laser ablation for complex 3D devices, achieving width channels down to 13μ m on 50μ m SU-8 thickness using direct writing lithography, and width channels of 40 μm for polyimide on SiO2 plate. Finally, we have tested the use of some devices for capillary chips measuring the flow speed for liquids with different viscosities. As a result, we have characterized the presence of liquid in the channel by interferometric microscopy

    Vertical resonant microcativites based on pillars analyzed by beam profile ellipsometry and reflectometry

    Get PDF
    A biosensor design is presented by a combination of ellipsometry, reflectometry and spectrometry based techniques is presented. It consists of a lattice of columns forming resonant microcavities. Calculations for reflectivity profiles are shown, and estimations for detection limit in refractive index units are obtained

    Incertidumbre en bio-sensores ópticos asociada al desplazamiento espectral de los modos de interferencia de la señal de transducción

    Get PDF
    El análisis del comportamiento de los modos de interferencia tiene una aplicación cada vez mas amplia, especialmente en el campo de los biosensores opticos. En este tipo de sensores se observa el desplazamiento Δν de los modos de interferencia de la señal de transducción al reconocer un determinado agente biologico. Para medir ese desplazamiento se debe detectar la posición de un máximo o minimo de la senal antes y después de dicho desplazamiento. En este tipo de biosensores un parámetro de gran importancia es el periodo Pν de la senal el cual es inversamente proporcional al espesor óptico h0 del sensor en ausencia de agente biologico. El aumento de dicho periodo mejora la sensibilidad del sensor pero parece dificultar la detección del minimo o maximo. Por tanto, su efecto sobre la incetidumbre del resultado de la medida presentados efectos contrapuestos: la mejora de la sensibilidad frente a la dificultad creciente en la detección del minimo o maximo. En este trabajo, los autores analizan la propagación de incertidumbres en estos sensores utilizando herramientas de ajuste por MM.CC. para la detección de los minimos o máximos de la senal y técnicas de propagación de incertidumbres descritas en los suplementos 2 de la Guia ISO-GUM. El resultado del análisis permite dar una respuesta, justificada desde el punto de vista metrologico, de en que condiciones es conveniente o no aumentar el periodo Pν de la senal

    Label-free biosensing for dry eye by Means of BICELLS

    Get PDF
    The use of Biophotonic Sensing Cells (BICELLs) based on micro-nano pattemed photonic architectures has been recently proven as an efficient methodology for label-free biosensing by using Optical Interrogation [1]. According to this, we have studied the different optical response for a specific typology of BICELL, consisting of structures of SU -8. This material is biocompatible with different types of biomolecules and can be immobilized on its sensing surface. In particular, we have measured the optical response for a biomarker in clinic diagnostic of dry eye. Although different proteins can be enstudied such as: PRDX5, ANXA 1, ANXA 11, CST 4, PLAA Y S 1 OOA6 related with ocular surface (dry eye), for this work PLAA (phospholipase A2) is studied by means of label free biosensing based on BICELLs for analyzing the performance and specificity according with means values of concentration in ROC curves

    Biophotonic Sensing Cells (BICELLs) for label-free biosensing

    Get PDF
    Label free immunoassay sector is a ferment of activity, experiencing rapid growth as new technologies come forward and achieve acceptance. The landscape is changing in a “bottom up” approach, as individual companies promote individual technologies and find a market for them. Therefore, each of the companies operating in the label-free immunoassay sector offers a technology that is in some way unique and proprietary. However, no many technologies based on Label-free technology are currently in the market for PoC and High Throughput Screening (HTS), where mature labeled technologies have taken the market

    Uncertainty in optical bio-sensors due to the spectral displacement of the interference modes of the transduction signal. Incertidumbre en bio-sensores ópticos asociada al desplazamiento espectral de los modos de interferencia de la señal de transducción

    Get PDF
    The analysis of the interference modes has an increasing application, especially in the field of optical biosensors. In this type of sensors, the displacement Δν of the interference modes of the transduction signal is observed when a particular biological agent is placed over the biosensor. In order to measure this displacement, the position of a maximum (or a minimum) of the signal must be detected before and after placing the agent over the sensor. A parameter of great importance for this kind of sensors is the period Pν of the signal, which is inversely proportional to the optical thickness h0 of the sensor in the absence of the biological agent. The increase of this period improves the sensitivity of the sensor but it worsens the detection of the maximum. In this paper, authors analyze the propagation of uncertainties in these sensors when using least squares techniques for the detection of the maxima (or minima) of the signal. Techniques described in supplement 2 of the ISO-GUM Guide are used. The result of the analysis allows a metrological educated answer to the question of which is the optimal period Pν of the signal. El análisis del comportamiento de los modos de interferencia tiene una aplicación cada vez más amplia, especialmente en el campo de los biosensores ópticos. En este tipo de sensores se observa el desplazamiento Δν de los modos de interferencia de la señal de transducción al reconocer un de-terminado agente biológico. Para medir ese desplazamiento se debe detectar la posición de un máximo o mínimo de la señal antes y después de dicho desplazamiento. En este tipo de biosensores un parámetro de gran importancia es el periodo Pν de la señal el cual es inversamente proporcional al espesor óptico h0 del sensor en ausencia de agente biológico. El aumento de dicho periodo mejora la sensibilidad del sensor pero parece dificultar la detección del mínimo o máximo. Por tanto, su efecto sobre la incertidumbre del resultado de la medida presenta dos efectos contrapuestos: la mejora de la sensibilidad frente a la dificultad creciente en la detección del mínimo ó máximo. En este trabajo, los autores analizan la propagación de incertidumbres en estos sensores utilizando herramientas de ajuste por MM.CC. para la detección de los mínimos o máximos de la señal y técnicas de propagación de incertidumbres descritas en el suplemento 2 de la Guía ISO-GUM. El resultado del análisis permite dar una respuesta, justificada desde el punto de vista metrológico, de en que condiciones es conveniente o no aumentar el periodo Pν de la señal

    Biophotonic Sensing Cells Optimization for label-free biosensing

    Full text link
    Los sectores de detección biológica demandan continuamente técnicas de análisis y diagnóstico más eficientes y precisas para identificar enfermedades y desarrollar nuevos medicamentos. Actualmente se considera que hay una gran necesidad de desarrollar herramientas de diagnóstico capaces de asegurar sensibilidad, rapidez, sencillez y asequibilidad para aplicaciones en sectores como la salud, la alimentación, el medioambiente o la seguridad. En el ámbito clínico se necesitan profundos avances tecnológicos capaces de ofrecer análisis rápidos, exactos, fiables y asequibles en coste y que tengan como consecuencia la mejora clínica y económica a partir de un diagnóstico eficiente. En concreto, hay un interés creciente por la descentralización del diagnóstico clínico mediante plataformas de detección cercanas al usuario final, denominadas POCs (Point Of Care devices). La utilización de POCs (referidas al diagnóstico cercano al usuario final o fuera del laboratorio de análisis clínico), mediante detección in vitro (IVD), será extremadamente útil en centros de salud, clínicas o unidades hospitalarias, entornos laborales o incluso en el hogar. Por otra parte, el desarrollo de la genómica, proteómica y otras tecnologías conocidas como “omics” (sufijo en inglés para referirse, por ejemplo, a genomics, transcriptomics, proteomics, metabolomics, lipidomics) está incrementando la demanda de nuevas tecnologías mucho más avanzadas con una clara orientación hacia la medicina personalizada y la necesidad de hacer frente a cambios en los tratamientos en el caso de enfermedades complejas. Desde hace poco tiempo se han definido las Celdas Biofónicas (BICELLs) como una metodología novedosa para la detección de agentes biológicos que ofrecen una serie de características que las hacen interesantes como son: Capacidad de multiplexación, alta sensibilidad, posibilidad de medir en gota, compatible con otras tecnologías. En este trabajo se hace un estudio y optimización sobre diferentes tipos de BICELLs y se valoran una serie de figuras de merito a tener en cuenta desde el punto de vista del lector óptico a emplear
    corecore