4 research outputs found

    Comparison of central corneal thickness and anterior chamber depth measurements using three imaging technologies in normal eyes and after phakic intraocular lens implantation

    Get PDF
    Contains fulltext : 81835.pdf (Publisher’s version ) (Open Access)BACKGROUND: The repeatability and interchangeability of imaging devices measuring central corneal thickness (CCT) and anterior chamber depth (ACD) are important in the assessment of patients considering refractive surgery. The purpose of this study was to investigate the agreement of CCT and ACD measurements using three imaging technologies in healthy eyes and in eyes after phakic intraocular lens implantation (pIOL). METHODS: In this comparative study, CCT and ACD were measured using anterior segment optical coherence tomography (AS-OCT), Orbscan II, and Pentacam in 33 healthy volunteers (66 eyes) and 22 patients (42 eyes) after pIOL implantation. Intraobserver repeatability was evaluated for all three devices in the healthy volunteer group. RESULTS: Pairwise comparison of CCT measurements showed significant differences between all devices (P < 0.001), except for the AS-OCT and Orbscan II in the healthy volunteer group (P = 0.422) and the Orbscan II and Pentacam in the pIOL group (P = 0.214). ACD measurements demonstrated significant differences between all pairwise comparisons in both groups (P < or = 0.001). Intraobserver reliability was high for CCT and ACD measurements in the healthy volunteer group, with coefficients of variation ranging from 0.6% to 1.2% and 0.4% to 0.5% respectively. CONCLUSIONS: CCT and ACD measurements using AS-OCT, Orbscan II, and Pentacam demonstrated high intraobserver reliability. However, these devices should not be used interchangeably for measurements of CCT and ACD in healthy subject and patients after pIOL implantation

    Incidence of primary open angle glaucoma in the Andhra Pradesh Eye Disease Study (APEDS)

    No full text
    Background: To report 15-year incidence rate of primary open angle glaucoma (POAG) in the Andhra Pradesh Eye Disease Study (APEDS). Methods: A population-based longitudinal study was carried out at three rural study sites. Phakic participants aged ≥40 years who participated at baseline (APEDS I) and the mean 15-year follow-up visit (APEDS III) were included. A comprehensive ophthalmic examination was performed on all participants. Mean intraocular pressure (IOP) was average of IOPs of right and left eyes. The definition of glaucoma was based on the International Society of Geographical and Epidemiological Ophthalmology (ISGEO) classification. The main outcome measure was incidence of POAG during the follow-up period in participants without glaucoma or suspicion of glaucoma at baseline. Results: Data from the available and eligible participants from the original cohort (1241/2790; 44.4%) were analysed. The mean age (standard deviation) of participants at baseline was 50.2 (8.1) years; 580 (46.7%) were men. Thirty-six participants developed POAG [bilateral in 17 (47.2%)] over 15 years. The incidence rate of POAG per 100-person years (95% confidence interval) was 2.83 (2.6, 3.08). Compared to baseline, the reduction in mean IOP [median (range) mm Hg] was −0.75 (−7.5, 9) in participants with incident POAG and −2.5 (−14.5, 14.5) in those without. The inter-visit difference in mean IOP was a significant risk factor on logistic regression analysis. Conclusion: We report the long-term incidence of POAG in rural India. A longitudinal change in IOP, specifically a less pronounced reduction in IOP with increasing age, was a novel risk factor
    corecore