2,038 research outputs found

    Chemical event tracking using a low-cost wireless chemical sensing network

    Get PDF
    A recently developed low-cost light emitting diode (LED) chemical sensing technique is integrated with a Mica2Dot wireless communications platform to form a deployable wireless chemical event indicator network. The operation of the colorimetric sensing node has been evaluated to determine its reproducibility and limit of detection for an acidic airborne contaminant. A test-scale network of five similar chemical sensing nodes is deployed in a star communication topology at fixed points within a custom built Environmental Sensing Chamber (ESC). Presented data sets collected from the deployed wireless chemical sensor network (WCSN) show that during an acidic event scenario it is possible to track the plume speed and direction, and estimate the concentration of chemical plume by examining the collective sensor data relative to individual sensor node location within the monitored environment

    Automatic reaction to a chemical event detected by a low-cost wireless chemical sensing network

    Get PDF
    A test-scale wireless chemical sensor network (WCSN) has been deployed within a controlled Environmental Chamber (EC). The combined signals from the WCSN were used to initiate a controllable response to the detected chemical event. When a particular sensor response pattern was obtained, a purging cycle was initiated. Sensor data were continuously checked against user-defined action limits, to determine if a chemical event had occurred. An acidic contaminant was used to demonstrate the response of the sensor network. Once the acid plume was simultaneously detected by a number of wireless chemical sensor nodes, an automatic response action, which was the purging of the EC with clean air, was initiated and maintained for a period of time until the WCSN indicated that normal status had been re-established

    Development of bite guard for wireless monitoring of bruxism using pressure-sensitive polymer

    Get PDF
    A wireless pressure sensing bite guard has been developed for monitoring the progress of bruxism (teeth grinding during sleep); as well as for protecting the teeth from damages. For sensing the grinding event effectively in restricted space and hostile environment, a pressure sensitive polymer composite which is safe for intra oral applications has been fabricated and encapsulated into a conventional bite guard. Also encapsulated was a microcontroller-based electronic circuit which was built in-house for data collection and transmission. A low power approach was configured to maximize the working life-time of the device to several months. The device can provide real-time tooth grinding profile through wireless communication. This device is anticipated to be a useful tool for understanding and treating bruxism

    The optimisation of a paired emitter-detector diode optical pH sensing device

    Get PDF
    With recent improvements in wireless sensor network hardware there has been a concurrent push to develop sensors that are suitable in terms of price and performance. In this paper a low cost gas sensor is detailed, and significant improvements in sensor characteristics have been achieved compared to previously published results. A chemical sensor is presented based on the use of low cost LEDs as both the light source and photodetector, coupled with a sensor slide coated with a pH sensitive colorimetric dye to create a simple gas sensor. Similar setups have been successfully used to detect both acetic acid and ammonia. The goal of this work was to optimise the system performance by integration of the sensing technique into a purposely deigned flowcell platform that holds the colorimetric slide and optical detector in position. The reproducibility of the sensor has been improved through this arrangement and careful control of deposited film thickness. The enhanced reproducibility between sensors opens the potential of calibration-free measurement, in that calibration of one sensor can be used to model the characteristics of all sensors in a particular batch

    Clinical measurements versus patient-reported outcomes: analysis of the American Shoulder and Elbow Surgeons physician assessment in patients undergoing reverse total shoulder arthroplasty.

    Get PDF
    BackgroundThe American Shoulder and Elbow Surgeons (ASES) score is composed of a patient-reported portion and a physician assessment. Although the patient-reported score is frequently used to assess postoperative outcomes after shoulder arthroplasty, no previous studies have used the physician-assessment component. This study evaluated the relationship of the ASES physician-assessment measurements with patient-reported shoulder and general health outcomes.MethodsA retrospective review of a prospectively collected multicenter database was used to analyze patients who underwent primary reverse total shoulder arthroplasty (RTSA) from 2012 to 2015 with a minimum 2-year follow-up. ASES physician-assessment and patient-reported components and 12-Item Short Form Health Survey (SF-12) general health questionnaires were obtained preoperatively and 2 years postoperatively. The relationship between ASES physician measurements with ASES patient-reported outcome (PRO) scores and SF-12 Physical and Mental domain scores was assessed with Pearson correlation coefficients.ResultsIncluded were 74 patients (32 men; mean age, 69.2 years; body mass index, 29.4 kg/m2). Preoperative physician measurements and PRO scores were not significantly correlated. Postoperatively, only the ASES physician-measured active (R = 0.54, P < .01) and passive forward flexion (R = 0.53, P < .01) demonstrated moderate correlation with ASES patient scores. The remaining clinical measurements had no significant correlations with ASES patient or SF-12 scores. During the 2-year period, only improvements in active forward flexion correlated with improvements in ASES patient scores (R = 0.36, P < .01).ConclusionsLittle correlation exists between clinical measurements from the ASES physician component and PROs, including the ASES patient-reported and SF-12 general health surveys, in RTSA patients. Improvement in active forward flexion is the only clinical measurement correlated with PRO improvement at 2 years

    Composite Suspension for a Mass Market Vehicle

    Get PDF
    Statement of Confidentiality: The complete senior project report was submitted to the project advisor and sponsor. The results of this project are of a confidential nature and will not be published at this time
    • 

    corecore