7 research outputs found

    Challenges and solutions to system-wide use of precision oncology as the standard of care paradigm

    Get PDF
    The personalised oncology paradigm remains challenging to deliver despite technological advances in genomics-based identification of actionable variants combined with the increasing focus of drug development on these specific targets. To ensure we continue to build concerted momentum to improve outcomes across all cancer types, financial, technological and operational barriers need to be addressed. For example, complete integration and certification of the ‘molecular tumour board’ into ‘standard of care’ ensures a unified clinical decision pathway that both counteracts fragmentation and is the cornerstone of evidence-based delivery inside and outside of a research setting. Generally, integrated delivery has been restricted to specific (common) cancer types either within major cancer centres or small regional networks. Here, we focus on solutions in real-world integration of genomics, pathology, surgery, oncological treatments, data from clinical source systems and analysis of whole-body imaging as digital data that can facilitate cost-effectiveness analysis, clinical trial recruitment, and outcome assessment. This urgent imperative for cancer also extends across the early diagnosis and adjuvant treatment interventions, individualised cancer vaccines, immune cell therapies, personalised synthetic lethal therapeutics and cancer screening and prevention. Oncology care systems worldwide require proactive step-changes in solutions that include inter-operative digital working that can solve patient centred challenges to ensure inclusive, quality, sustainable, fair and cost-effective adoption and efficient delivery. Here we highlight workforce, technical, clinical, regulatory and economic challenges that prevent the implementation of precision oncology at scale, and offer a systematic roadmap of integrated solutions for standard of care based on minimal essential digital tools. These include unified decision support tools, quality control, data flows within an ethical and legal data framework, training and certification, monitoring and feedback. Bridging the technical, operational, regulatory and economic gaps demands the joint actions from public and industry stakeholders across national and global boundaries

    On the use of solid 133Ba sources as surrogate for liquid 131I in SPECT/CT calibration: a European multi-centre evaluation

    No full text
    Abstract Introduction Commissioning, calibration, and quality control procedures for nuclear medicine imaging systems are typically performed using hollow containers filled with radionuclide solutions. This leads to multiple sources of uncertainty, many of which can be overcome by using traceable, sealed, long-lived surrogate sources containing a radionuclide of comparable energies and emission probabilities. This study presents the results of a quantitative SPECT/CT imaging comparison exercise performed within the MRTDosimetry consortium to assess the feasibility of using 133Ba as a surrogate for 131I imaging. Materials and methods Two sets of four traceable 133Ba sources were produced at two National Metrology Institutes and encapsulated in 3D-printed cylinders (volume range 1.68–107.4 mL). Corresponding hollow cylinders to be filled with liquid 131I and a mounting baseplate for repeatable positioning within a Jaszczak phantom were also produced. A quantitative SPECT/CT imaging comparison exercise was conducted between seven members of the consortium (eight SPECT/CT systems from two major vendors) based on a standardised protocol. Each site had to perform three measurements with the two sets of 133Ba sources and liquid 131I. Results As anticipated, the 131I pseudo-image calibration factors (cps/MBq) were higher than those for 133Ba for all reconstructions and systems. A site-specific cross-calibration reduced the performance differences between both radionuclides with respect to a cross-calibration based on the ratio of emission probabilities from a median of 12–1.5%. The site-specific cross-calibration method also showed agreement between 133Ba and 131I for all cylinder volumes, which highlights the potential use of 133Ba sources to calculate recovery coefficients for partial volume correction. Conclusion This comparison exercise demonstrated that traceable solid 133Ba sources can be used as surrogate for liquid 131I imaging. The use of solid surrogate sources could solve the radiation protection problem inherent in the preparation of phantoms with 131I liquid activity solutions as well as reduce the measurement uncertainties in the activity. This is particularly relevant for stability measurements, which have to be carried out at regular intervals

    On the Use of Solid 133Ba Sources as Surrogate for Liquid 131I in SPECT/CT Calibration - a European Multi-Centre Evaluation

    No full text
    International audienceIntroductionCommissioning, calibration, and quality control procedures for nuclear medicine imaging systems are typically performed using hollow containers filled with radionuclide solutions. This leads to multiple sources of uncertainty, many of which can be overcome by using traceable, sealed, long-lived surrogate sources containing a radionuclide of comparable energies and emission probabilities. This study presents the results of a quantitative SPECT/CT imaging comparison exercise performed within the MRTDosimetry consortium to assess the feasibility of using 133Ba as a surrogate for 131I imaging.Materials and methodsTwo sets of four traceable 133Ba sources were produced at two National Metrology Institutes and encapsulated in 3D-printed cylinders (volume range 1.68–107.4 mL). Corresponding hollow cylinders to be filled with liquid 131I and a mounting baseplate for repeatable positioning within a Jaszczak phantom were also produced. A quantitative SPECT/CT imaging comparison exercise was conducted between seven members of the consortium (eight SPECT/CT systems from two major vendors) based on a standardised protocol. Each site had to perform three measurements with the two sets of 133Ba sources and liquid 131I.ResultsAs anticipated, the 131I pseudo-image calibration factors (cps/MBq) were higher than those for 133Ba for all reconstructions and systems. A site-specific cross-calibration reduced the performance differences between both radionuclides with respect to a cross-calibration based on the ratio of emission probabilities from a median of 12–1.5%. The site-specific cross-calibration method also showed agreement between 133Ba and 131I for all cylinder volumes, which highlights the potential use of 133Ba sources to calculate recovery coefficients for partial volume correction.ConclusionThis comparison exercise demonstrated that traceable solid 133Ba sources can be used as surrogate for liquid 131I imaging. The use of solid surrogate sources could solve the radiation protection problem inherent in the preparation of phantoms with 131I liquid activity solutions as well as reduce the measurement uncertainties in the activity. This is particularly relevant for stability measurements, which have to be carried out at regular intervals

    Novel Benchmark for Adult-to-Adult Living-donor Liver Transplantation:Integrating Eastern and Western Experiences

    No full text
    Objective: To define benchmark values for adult-to-adult living-donor liver transplantation (LDLT). Background: LDLT utilizes living-donor hemiliver grafts to expand the donor pool and reduce waitlist mortality. Although references have been established for donor hepatectomy, no such information exists for recipients to enable conclusive quality and comparative assessments. Methods: Patients undergoing LDLT were analyzed in 15 high-volume centers (≥10 cases/year) from 3 continents over 5 years (2016-2020), with a minimum follow-up of 1 year. Benchmark criteria included a Model for End-stage Liver Disease ≤20, no portal vein thrombosis, no previous major abdominal surgery, no renal replacement therapy, no acute liver failure, and no intensive care unit admission. Benchmark cutoffs were derived from the 75th percentile of all centers' medians. Results: Of 3636 patients, 1864 (51%) qualified as benchmark cases. Benchmark cutoffs, including posttransplant dialysis (≤4%), primary nonfunction (≤0.9%), nonanastomotic strictures (≤0.2%), graft loss (≤7.7%), and redo-liver transplantation (LT) (≤3.6%), at 1-year were below the deceased donor LT benchmarks. Bile leak (≤12.4%), hepatic artery thrombosis (≤5.1%), and Comprehensive Complication Index (CCI ®) (≤56) were above the deceased donor LT benchmarks, whereas mortality (≤9.1%) was comparable. The right hemiliver graft, compared with the left, was associated with a lower CCI ® score (34 vs 21, P &lt; 0.001). Preservation of the middle hepatic vein with the right hemiliver graft had no impact neither on the recipient nor on the donor outcome. Asian centers outperformed other centers with CCI ® score (21 vs 47, P &lt; 0.001), graft loss (3.0% vs 6.5%, P = 0.002), and redo-LT rates (1.0% vs 2.5%, P = 0.029). In contrast, non-benchmark low-volume centers displayed inferior outcomes, such as bile leak (15.2%), hepatic artery thrombosis (15.2%), or redo-LT (6.5%). Conclusions: Benchmark LDLT offers a valuable alternative to reduce waitlist mortality. Exchange of expertise, public awareness, and centralization policy are, however, mandatory to achieve benchmark outcomes worldwide.</p

    Electronic monitoring in fisheries: Lessons from global experiences and future opportunities

    Get PDF
    Since the beginning of the 21st century, electronic monitoring (EM) has emerged as a cost‐efficient supplement to existing catch monitoring programmes in fisheries. An EM system consists of various activity sensors and cameras positioned on vessels to remotely record fishing activity and catches. The first objective of this review was to describe the state of play of EM in fisheries worldwide and to present the insights gained on this technology based on 100 EM trials and 12 fully implemented programmes. Despite its advantages, and its global use for monitoring, progresses in implementation in some important fishing regions are slow. Within this context, the second objective was to discuss more specifically the European experiences gained through 16 trials. Findings show that the three major benefits of EM were as follows: (a) cost‐efficiency, (b) the potential to provide more representative coverage of the fleet than any observer programme and (c) the enhanced registration of fishing activity and location. Electronic monitoring can incentivize better compliance and discard reduction, but the fishing managers and industry are often reluctant to its uptake. Improved understanding of the fisher's concerns, for example intrusion of privacy, liability and costs, and better exploration of EM benefits, for example increased traceability, sustainability claims and market access, may enhance implementation on a larger scale. In conclusion, EM as a monitoring tool embodies various solid strengths that are not diminished by its weaknesses. Electronic monitoring has the opportunity to be a powerful tool in the future monitoring of fisheries, particularly when integrated within existing monitoring programmes

    Characteristics and outcomes of COVID-19 patients admitted to hospital with and without respiratory symptoms

    No full text
    Background: COVID-19 is primarily known as a respiratory illness; however, many patients present to hospital without respiratory symptoms. The association between non-respiratory presentations of COVID-19 and outcomes remains unclear. We investigated risk factors and clinical outcomes in patients with no respiratory symptoms (NRS) and respiratory symptoms (RS) at hospital admission. Methods: This study describes clinical features, physiological parameters, and outcomes of hospitalised COVID-19 patients, stratified by the presence or absence of respiratory symptoms at hospital admission. RS patients had one or more of: cough, shortness of breath, sore throat, runny nose or wheezing; while NRS patients did not. Results: Of 178,640 patients in the study, 86.4&nbsp;% presented with RS, while 13.6&nbsp;% had NRS. NRS patients were older (median age: NRS: 74 vs RS: 65) and less likely to be admitted to the ICU (NRS: 36.7&nbsp;% vs RS: 37.5&nbsp;%). NRS patients had a higher crude in-hospital case-fatality ratio (NRS 41.1&nbsp;% vs. RS 32.0&nbsp;%), but a lower risk of death after adjusting for confounders (HR 0.88 [0.83-0.93]). Conclusion: Approximately one in seven COVID-19 patients presented at hospital admission without respiratory symptoms. These patients were older, had lower ICU admission rates, and had a lower risk of in-hospital mortality after adjusting for confounders
    corecore