42 research outputs found

    Nerve Sheath Tumors in Neurofibromatosis Type 1: Assessment of Whole-Body Metabolic Tumor Burden Using F-18-FDG PET/CT.

    No full text
    To determine the metabolically active whole-body tumor volume (WB-MTV) on F-18-fluorodeoxyglucose positron emission tomography/computed tomography (F-18-FDG PET/CT) in individuals with neurofibromatosis type 1 (NF1) using a three-dimensional (3D) segmentation and computerized volumetry technique, and to compare PET WB-MTV between patients with benign and malignant peripheral nerve sheath tumors (PNSTs).Thirty-six NF1 patients (18 patients with malignant PNSTs and 18 age- and sex-matched controls with benign PNSTs) were examined by F-18-FDG PET/CT. WB-MTV, whole-body total lesion glycolysis (WB-TLG) and a set of semi-quantitative imaging-based parameters were analyzed both on a per-patient and a per-lesion basis.On a per-lesion basis, malignant PNSTs demonstrated both a significantly higher MTV and TLG than benign PNSTs (p < 0.0001). On a per-patient basis, WB-MTV and WB-TLG were significantly higher in patients with malignant PNSTs compared to patients with benign PNSTs (p < 0.001). ROC analysis showed that MTV and TLG could be used to differentiate between benign and malignant tumors.WB-MTV and WB-TLG may identify malignant change and may have the potential to provide a basis for investigating molecular biomarkers that correlate with metabolically active disease manifestations. Further evaluation will determine the potential clinical impact of these PET-based parameters in NF1

    Structural alteration of lung parenchyma in patients with NF1: a phenotyping study using multidetector computed tomography (MDCT)

    No full text
    Background!#!Diffuse interstitial lung disease have been described in Neurofibromatosis type 1 (NF1), but its diversity and prevalence remain unknown. The aim of this study was to assess the prevalence and characteristics of (NF1)-associated lung manifestations in a large single-center study using multidetector computed tomography (MDCT) and to evaluate the smoking history, patients' age, genetics, and the presence of malignant peripheral nerve sheath tumors (MPNST) as potential influencing factors for lung pathologies.!##!Methods!#!In this retrospective study, 71 patients with NF1 were evaluated for the presence of distinctive lung manifestations like reticulations, consolidations, type of emphysema, pulmonary nodules and cysts. All patients underwent F-18-FDG PET/CT scans, which were reviewed by two experienced radiologists in consensus. Patients' subgroups were formed based on their smoking history (current smokers/previous smokers/never smokers), age (&amp;lt; 12 years, 12-18 years, &amp;gt; 18 years), and presence of MPNST (MPNST/no MPNST). In 57 patients (80%), genetic analysis of sequences coding for the neurofibromin on chromosome 17 was performed, which was correlated with different lung pathologies.!##!Results!#!Among all NF1 patients (33 ± 14 years, 56% females), 17 patients (24%) were current smokers and 62 patients (87%) were &amp;gt; 18 years old. Pulmonary cysts, nodules, and paraseptal emphysema were the most common pulmonary findings (35%, 32%, 30%). The presence of pulmonary metastases, MPNST and centrilobular emphysema was associated with smoking. Cysts were observed only in adults, whereas no significant correlation between age and all other pulmonary findings was found (p &amp;gt; 0.05). Presence of MPNST was accompanied by higher rates of intrapulmonary nodules and pulmonary metastasis. Neither the presence nor absence of any of the specific gene mutations was associated with any particular lung pathology (p &amp;gt; 0.05).!##!Conclusions!#!All pulmonary findings in NF1 patients occurred independently from specific mutation subtypes, suggesting that many NF1 mutations can cause various pulmonary pathologies. The presence of pulmonary metastases, MPNST and centrilobular emphysema was associated with smoking, indicating the value of smoking secession or the advice not to start smoking in NF1 patients as preventive strategy for clinicians. For screening of pulmonary manifestations in NF1 patients, an MDCT besides medical history and physical examination is mandatory in clinical routine

    Impact of Hybrid Iterative Reconstruction on Agatston Coronary Artery Calcium Scores in Comparison to Filtered Back Projection in Native Cardiac CT

    No full text
    PURPOSE To investigate whether the effects of hybrid iterative reconstruction (HIR) on coronary artery calcium (CAC) measurements using the Agatston score lead to changes in assignment of patients to cardiovascular risk groups compared to filtered back projection (FBP). MATERIALS AND METHODS 68 patients (mean age 61.5 years; 48 male; 20 female) underwent prospectively ECG-gated, non-enhanced, cardiac 256-MSCT for coronary calcium scoring. Scanning parameters were as follows: Tube voltage, 120 kV; Mean tube current time-product 63.67 mAs (50 - 150 mAs); collimation, 2 × 128 × 0.625 mm. Images were reconstructed with FBP and with HIR at all levels (L1 to L7). Two independent readers measured Agatston scores of all reconstructions and assigned patients to cardiovascular risk groups. Scores of HIR and FBP reconstructions were correlated (Spearman). Interobserver agreement and variability was assessed with ĸ-statistics and Bland-Altmann-Plots. RESULTS Agatston scores of HIR reconstructions were closely correlated with FBP reconstructions (L1, R = 0.9996; L2, R = 0.9995; L3, R = 0.9991; L4, R = 0.986; L5, R = 0.9986; L6, R = 0.9987; and L7, R = 0.9986). In comparison to FBP, HIR led to reduced Agatston scores between 97 % (L1) and 87.4 % (L7) of the FBP values. Using HIR iterations L1 - L3, all patients were assigned to identical risk groups as after FPB reconstruction. In 5.4 % of patients the risk group after HIR with the maximum iteration level was different from the group after FBP reconstruction. CONCLUSION There was an excellent correlation of Agatston scores after HIR and FBP with identical risk group assignment at levels 1 - 3 for all patients. Hence it appears that the application of HIR in routine calcium scoring does not entail any disadvantages. Thus, future studies are needed to demonstrate whether HIR is a reliable method for reducing radiation dose in coronary calcium scoring

    Inter- and Intraobserver reproducibility of T2 relaxation times of the discus interpubicus: A feasibility study at 3 Tesla.

    No full text
    OBJECTIVE:To quantify standard values of the discus interpubicus in healthy subjects and to determine reliability and repeatability using T2 relaxation time measurements at 3T. METHODS:20 asymptomatic participants (10 male, 10 female; mean age: 27.3 years ±4.1, BMI: 22.2 ±1.8) underwent a 3T Magnetic Resonance Imaging (MRI) of the pelvic region in a supine position. We included sagittal and para-axial T2w sequences centred over the pubic symphysis in order to identify the complete discus interpubicus. For quantitative analysis, a multi-echo Turbo Spin Echo (TSE) sequence (including 12 echo times between 6.4 and 76.8 ms) was acquired and analysed by using an in-house developed quantification plugin tool (qMapIt) extending ImageJ. Two readers in consensus defined three central slices of the pubic symphysis with the greatest length. For each slice, both readers separately placed three regions-of-interest (ROI) covering the whole discus interpubicus. Both readers repeated the ROI placements in identical fashion after a four-week interval on the original MRI images. Statistical analysis included intraclass correlation coefficient (ICC), nonparametric Wilcoxon test, Fisher exact test and mean relaxation time in ms and 95% confidence intervals. RESULTS:T2 relaxation time analysis was performed for all 20 participants. In total, a mean relaxation time of all analysed segments for both observers was 48.6 (±6.3 ms), with a mean relaxation time for observer 1 of 48.7 (±6.0 ms) and for observer 2 of 48.5 ms (±6.6ms). The calculated ICC comparing inter- and intrarater reproducibility was excellent in all segments (≥0.75). CONCLUSION:T2 mapping of the discus interpubicus demonstrates good inter- and intrarater repeatability as well as reliability. Mean relaxation times were calculated with 48.6ms in healthy volunteers

    CT Pulmonary Angiography at Reduced Radiation Exposure and Contrast Material Volume Using Iterative Model Reconstruction and iDose4 Technique in Comparison to FBP.

    No full text
    PURPOSE:To assess image quality of CT pulmonary angiography (CTPA) at reduced radiation exposure (RD-CTPA) and contrast medium (CM) volume using two different iterative reconstruction (IR) algorithms (iDose4 and iterative model reconstruction (IMR)) in comparison to filtered back projection (FBP). MATERIALS AND METHODS:52 patients (body weight < 100 kg, mean BMI: 23.9) with suspected pulmonary embolism (PE) underwent RD-CTPA (tube voltage: 80 kV; mean CTDIvol: 1.9 mGy) using 40 ml CM. Data were reconstructed using FBP and two different IR algorithms (iDose4 and IMR). Subjective and objective image quality and conspicuity of PE were assessed in central, segmental, and subsegmental arteries. RESULTS:Noise reduction of 55% was achieved with iDose4 and of 85% with IMR compared to FBP. Contrast-to-noise ratio significantly increased with iDose4 and IMR compared to FBP (p<0.05). Subjective image quality was rated significantly higher at IMR reconstructions in comparison to iDose4 and FBP. Conspicuity of central and segmental PE significantly improved with the use of IMR. In subsegmental arteries, iDose4 was superior to IMR. CONCLUSIONS:CTPA at reduced radiation exposure and contrast medium volume is feasible with the use of IMR, which provides improved image quality and conspicuity of pulmonary embolism in central and segmental arteries
    corecore