31,441 research outputs found

    Towards more inclusive long-term bulk water resource management

    Get PDF
    Fresh water resources provide a platform for complex and often emotional issues to develop, particularly in resource scarcity situations. Bulk water infrastructure contains elements of a public good and proved vulnerable to failures in market and government driven allocation strategies. Common to both are uncaptured costs and benefits due to shortcomings in cost quantification techniques. Natural ecosystems stands to lose the most since ecosystem services are often not quantifiable in monetary terms and therefore neglected in allocation decision-making. This paper took on the challenge of expanding current decision-support in order to promote more inclusive long-term water management. A case-study approach with the focus on a choice related problem regarding different long-term bulk water resource management options was applied in the Western Cape province. The paper incorporated components of economic valuation theory, a public survey and a modified Delphi expert panel technique. Both spatial and temporal dimensions of the decision-making context were expanded. Two surveys were completed to accommodate these expansions. The first focused on public preference in water allocation management and the relative merit of accommodating public preference in highly specialised decision-making such as long-term water allocation decision-making. The second survey utilized a modified Delphi technique in which an expert panel indicated the relative merit of two alternative long-term allocation strategies. A willingness to pay for 'greener' water was observed and may be used to motivate a paradigm shift from management's perspective to consider, without fear of harming their own political position, 'greener' water supply options more seriously even if these options imply higher direct costs to public.water management, decision-support, public participation, Resource /Energy Economics and Policy,

    Planck pre-launch status: The HFI instrument, from specification to actual performance

    Get PDF
    Context. The High Frequency Instrument (HFI) is one of the two focal instruments of the Planck mission. It will observe the whole sky in six bands in the 100 GHz−1 THz range. Aims. The HFI instrument is designed to measure the cosmic microwave background (CMB) with a sensitivity limited only by fundamental sources: the photon noise of the CMB itself and the residuals left after the removal of foregrounds. The two high frequency bands will provide full maps of the submillimetre sky, featuring mainly extended and point source foregrounds. Systematic effects must be kept at negligible levels or accurately monitored so that the signal can be corrected. This paper describes the HFI design and its characteristics deduced from ground tests and calibration. Methods. The HFI instrumental concept and architecture are feasible only by pushing new techniques to their extreme capabilities, mainly: (i) bolometers working at 100 mK and absorbing the radiation in grids; (ii) a dilution cooler providing 100 mK in microgravity conditions; (iii) a new type of AC biased readout electronics and (iv) optical channels using devices inspired from radio and infrared techniques. Results. The Planck-HFI instrument performance exceeds requirements for sensitivity and control of systematic effects. During ground-based calibration and tests, it was measured at instrument and system levels to be close to or better than the goal specification

    Continuous detonation reaction engine

    Get PDF
    Reaction engine operates on the principles of a controlled condensed detonation rather than on the principles of gas expansion. The detonation results in reaction products that are expelled at a much higher velocity

    Development of detonation reaction engine

    Get PDF
    Reaction engine operates on the principle of a controlled condensed detonation. In this engine the gas products that are expelled from the engine to produce thrust are generated by the condensed detonation reaction. The engine is constructed of two basic sections consisting of a detonation wave generator section and a condensed detonation reaction section

    A low noise, high thermal stability, 0.1 K test facility for the Planck HFI bolometers

    Get PDF
    We are developing a facility which will be used to characterize the bolometric detectors for Planck, an ESA mission to investigate the Cosmic Microwave Background. The bolometers operate at 0.1 K, employing neutron-transmutation doped (NTD) Ge thermistors with resistances of several megohms to achieve NEPs~1×10^(–17) W Hz^(–1/2). Characterization of the intrinsic noise of the bolometers at frequencies as low as 0.010 Hz dictates a test apparatus thermal stability of 40 nK Hz^(–1/2) to that frequency. This temperature stability is achieved via a multi-stage isolation and control geometry with high resolution thermometry implemented with NTD Ge thermistors, JFET source followers, and dedicated lock-in amplifiers. The test facility accommodates 24 channels of differential signal readout, for measurement of bolometer V(I) characteristics and intrinsic noise. The test facility also provides for modulated radiation in the submillimeter band incident on the bolometers, for measurement of the optical speed-of-response; this illumination can be reduced below detectable limits without interrupting cryogenic operation. A commercial Oxford Instruments dilution refrigerator provides the cryogenic environment for the test facility

    Emissivity measurements of reflective surfaces at near-millimeter wavelengths

    Get PDF
    We have developed an instrument for directly measuring the emissivity of reflective surfaces at near-millimeter wavelengths. The thermal emission of a test sample is compared with that of a reference surface, allowing the emissivity of the sample to be determined without heating. The emissivity of the reference surface is determined by one’s heating the reference surface and measuring the increase in emission. The instrument has an absolute accuracy of Δe = 5 x 10^-4 and can reproducibly measure a difference in emissivity as small as Δe = 10^-4 between flat reflective samples. We have used the instrument to measure the emissivity of metal films evaporated on glass and carbon fiber-reinforced plastic composite surfaces. We measure an emissivity of (2.15 ± 0.4) x 10^-3 for gold evaporated on glass and (2.65 ± 0.5) x 10^-3 for aluminum evaporated on carbon fiber-reinforced plastic composite

    Parameter Estimation from Improved Measurements of the Cosmic Microwave Background from QUaD

    Get PDF
    We evaluate the contribution of cosmic microwave background (CMB) polarization spectra to cosmological parameter constraints. We produce cosmological parameters using high-quality CMB polarization data from the ground-based QUaD experiment and demonstrate for the majority of parameters that there is significant improvement on the constraints obtained from satellite CMB polarization data. We split a multi-experiment CMB data set into temperature and polarization subsets and show that the best-fit confidence regions for the ΛCDM six-parameter cosmological model are consistent with each other, and that polarization data reduces the confidence regions on all parameters. We provide the best limits on parameters from QUaD EE/BB polarization data and we find best-fit parameters from the multi-experiment CMB data set using the optimal pivot scale of k_p = 0.013 Mpc^(–1) to be {h^2Ω_c, h^2Ω_b, H_0, A_s, n_s, τ} = {0.113, 0.0224, 70.6, 2.29 × 10^(–9), 0.960, 0.086}

    Composite infrared bolometers with Si_3N_4 micromesh absorbers

    Get PDF
    We report the design and performance of 300-mK composite bolometers that use micromesh absorbers and support structures patterned from thin films of low-stress silicon nitride. The small geometrical filling factor of the micromesh absorber provides 20× reduction in heat capacity and cosmic ray cross section relative to a solid absorber with no loss in IR-absorption efficiency. The support structure is mechanically robust and has a thermal conductance, G < 2 × 10^(−11) W/K, which is four times smaller than previously achieved at 300 mK. The temperature rise of the bolometer is measured with a neutron transmutation doped germanium thermistor attached to the absorbing mesh. The dispersion in electrical and thermal parameters of a sample of 12 bolometers optimized for the Sunyaev–Zel’dovich Infrared Experiment is ±7% in R (T), ±5% in optical efficiency, and ±4% in G
    • 